MR-guided radiotherapy has different requirements for the images than diagnostic radiology, thus requiring development of novel imaging sequences. MRI simulation is an excellent tool for optimizing these new sequences; however, currently available software does not provide all the necessary features. In this paper, we present a digital framework for testing MRI sequences that incorporates anatomical structure, respiratory motion, and realistic presentation of MR physics. The extended Cardiac-Torso (XCAT) software was used to create T1 , T2 , and proton density maps that formed the anatomical structure of the phantom. Respiratory motion model was based on the XCAT deformation vector fields, modified to create a motion model driven by a respiration signal. MRI simulation was carried out with JEMRIS, an open source Bloch simulator. We developed an extension for JEMRIS, which calculates the motion of each spin independently, allowing for deformable motion. The performance of the framework was demonstrated through simulating the acquisition of a two-dimensional (2D) cine and demonstrating expected motion ghosts from T2 weighted spin echo acquisitions with different respiratory patterns. All simulations were consistent with behavior previously described in literature. Simulations with deformable motion were not more time consuming than with rigid motion. We present a deformable four-dimensional (4D) digital phantom framework for MR sequence development. The framework incorporates anatomical structure, realistic breathing patterns, deformable motion, and Bloch simulation to achieve accurate simulation of MRI. This method is particularly relevant for testing novel imaging sequences for the purpose of MR-guided radiotherapy in lungs and abdomen.

Loading PDF

Similar Papers
  • Research Article
  • Citations58

Patient specific respiratory motion modeling using a 3D patient's external surface.

  • May 24, 2012
  • Medical Physics
  • Hadi Fayad +3
  • Research Article
  • Citations3

Development and first implementation of a novel multi-modality cardiac motion and dosimetry phantom for radiotherapy applications.

  • Jul 23, 2024
  • Medical physics
  • Kenneth W Gregg +9
  • Conference Article
  • Citations4

Evaluation of two PET motion correction techniques for simultaneous real-time PET-MR acquisitions using an MR-derived motion model

  • Oct 01, 2012
  • Charalampos Tsoumpas +3
  • Conference Article
  • Citations13

Towards a generic respiratory motion model for 4D CT imaging of the thorax

  • Oct 01, 2009
  • H Fayad +6
  • Conference Article
  • Citations10

Deformable image-based motion compensation for interventional cone-beam CT with a learned autofocus metric

  • Feb 23, 2021
  • Alejandro Sisniega +6
  • Book Chapter
  • Citations2

A Bilinear Model for Temporally Coherent Respiratory Motion

  • Jan 01, 2014
  • Frank Preiswerk +1
  • Research Article
  • Citations8

A Kalman-Based Approach With EM Optimization for Respiratory Motion Modeling in Medical Imaging

  • Jul 01, 2019
  • IEEE Transactions on Radiation and Plasma Medical Sciences
  • Rhodri L Smith +3
  • Conference Article
  • Citations4

Development and evaluation of data-driven respiratory gating methods with simulated list-mode PET data

  • Oct 01, 2015
  • Jizhe Wang +2
  • Conference Article
  • Citations2

Using ITK to obtain motion transform in anatomically guided PET motion correction for simultaneous PET/MR

  • Oct 01, 2013
  • Ju-Chieh Cheng +1
  • PDF
  • Research Article
  • Citations27

Characterization of Respiratory and Cardiac Motion from Electro-Anatomical Mapping Data for Improved Fusion of MRI to Left Ventricular Electrograms

  • Nov 08, 2013
  • PLoS ONE
  • Sébastien Roujol +3
  • Research Article
  • Citations144

Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning.

  • Jan 01, 2015
  • Medical Physics
  • Eric S Paulson +3
  • Research Article
  • Citations9

Respiratory signal estimation for cardiac perfusion SPECT using deep learning.

  • Jul 31, 2023
  • Medical physics
  • Yuan Chen +4
  • Research Article
  • Citations8

Continuously Deforming 4D Voxel Phantom for Realistic Representation of Respiratory Motion in Monte Carlo Dose Calculation

  • Dec 01, 2016
  • IEEE Transactions on Nuclear Science
  • Min Cheol Han +9
  • Research Article
  • Citations54

Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator‐based four‐dimensional radiation delivery

  • May 17, 2005
  • Medical Physics
  • S Vedam +4
  • Research Article
  • Citations113

On the interplay effects with proton scanning beams in stage III lung cancer

  • Jan 23, 2014
  • Medical Physics
  • Yupeng Li +14
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.