• Home
  • Search
  • Technical Note: Robust individual thermoluminescence dosimeter tracking using optical fingerprinting.
  • Open Access IconOpen Access
  • Cite Icon1
  • https://doi.org/10.1002/mp.13895Copy DOI Icon

Technical Note: Robust individual thermoluminescence dosimeter tracking using optical fingerprinting.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accuracy. To improve individual TLD tracking robustness, we developed an optical fingerprinting method to identify the TLD-100 chips. Seven hundred and fifty-two images were initially captured using a digital microscope camera to build a feature library for both facets of 376 TLD-100 chips. A median intensity thresholding method was used to segment images into foreground and background. The affine transformation was used to register the segmented images to the same position. The fingerprint of each image was calculated from its registered image. All fingerprints were then recorded in an Elasticsearch® search database. The TLD fingerprint match was tested three times when the library was established and repeated once 20months later. All chips were irradiated at 0, 1, 4, and 8Gy on a calibrated clinical MV linac to establish the individual calibration curve. The true positive rate of identifying TLDs based on their optical fingerprints was 100% at initialization of the inventory. After 20months and multiple deployments for characterization, calibration, and dose measurement, the true positive match rate dropped to 99% with zero false-positive matches. The TLDs exhibited high self-consistency in the dose-response test with R2 between 0.988 and 1 with linear regression. The TLD-100 chips surface textures are unique and sufficient to support accurate identification based on the optical fingerprinting. This method provides inexpensive and robust management of the TLDs for individual calibration and dosimetry.

Similar Papers
  • Research Article
  • Citations34

Midplane dose determination during total body irradiation using in vivo dosimetry

  • Oct 01, 1998
  • Radiotherapy and Oncology
  • Montserrat Ribas +7
  • Research Article
  • Citations8

EFFECTIVE DOSE IN TWO DIFFERENT DENTAL CBCT SYSTEMS: NEWTOM VGi AND PLANMECA 3D MID.

  • Feb 16, 2017
  • Radiation Protection Dosimetry
  • Mohammad Ghaedizirgar +3
  • Research Article
  • Citations8

Peripheral dose measurements with diode and thermoluminescence dosimeters for intensity modulated radiotherapy delivered with conventional and un-conventional linear accelerator

  • Jan 01, 2013
  • Journal of Medical Physics / Association of Medical Physicists of India
  • Rajesh Kinhikar +9
  • Research Article

MO‐E‐204B‐05: A Novel Organ Dosimetry in an Anthropomorphic Phantom Using XRQA‐2 Radiochromic Film

  • Jun 01, 2010
  • Medical Physics
  • S Brady +5
  • Research Article
  • Citations7

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

  • May 06, 2022
  • Radiation Measurements
  • J.R Chandler +6
  • Research Article
  • Citations8

Estimation of effective radiation dose for physicians and staff members in contrast angiocardiography

  • Nov 01, 2000
  • Heart & Lung
  • I.A Al-Shakhrah +1
  • Research Article
  • Citations6

TLD Postal Dose Quality Audit Intercomparison for Megavolts Photon Beam of Radiotherapy Centers in Bangladesh

  • Jun 01, 2008
  • Journal of Nuclear Science and Technology
  • Md Shakilur Rahman +5
  • Research Article
  • Citations12

QA measurement of gamma-ray dose and neutron activation using TLD-400 for BNCT beam

  • Mar 13, 2018
  • Applied Radiation and Isotopes
  • Wen-Chyi Tsai +2
  • Research Article
  • Citations13

Neutron contribution to CaF/sub 2/:Mn thermoluminescent dosimeter response in mixed (n//spl gamma/) field environments

  • Dec 01, 2003
  • IEEE Transactions on Nuclear Science
  • K.R Depriest +1
  • Research Article
  • Citations1

Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter

  • Apr 01, 2023
  • Journal of Biomedical Physics & Engineering
  • Endarko Endarko +5
  • Research Article

High SNR fingerprinting structure for LC displays.

  • May 29, 2020
  • Optics Express
  • Kai Huang +3
  • Conference Article
  • Citations5

Exposure tool specific post-OPC verification

  • Mar 14, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • John Sturtevant +2
  • Discussion
  • Citations2

Intercomparison of Environmental Gamma doses Measured with A NaI (Tl) Survey Meter and Thermoluminescent Dosimeters (TLDs) in the Poonch Division of Azad Kashmir, Pakistan

  • Dec 10, 2014
  • Biomedical and Environmental Sciences
  • Muhammad Rafique +8
  • Research Article
  • Citations12

Estimation of organ cumulated activities and absorbed doses on intakes of several labelled radiopharmaceuticals from external measurement with thermoluminescent dosimeters

  • Feb 01, 1998
  • Physics in Medicine & Biology
  • Takashi Nakamura +7
  • Research Article
  • Citations72

Digital radiography of scoliosis with a scanning method: initial evaluation.

  • Feb 01, 2001
  • Radiology
  • Håkan Geijer +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.