Technical performance evaluation of a human brain PET/MRI system

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Technical performance evaluation of a human brain PET/MRI system. The magnetic field compatible positron emission tomography (PET) insert is based on avalanche photodiode (APD) arrays coupled with lutetium oxyorthosilicate (LSO) crystals and slip-fits into a slightly modified clinical 3-T MRI system. The mutual interference between the two imaging techniques was minimised by the careful design of the hardware to maintain the quality of the B (0) and B (1) field homogeneity. The signal-to-noise ratio (SNR) and the homogeneity of the MR images were minimally influenced by the presence of the PET. Measurements according to the Function Biomedical Informatics Research Network (FBIRN) protocol proved the combined system's ability to perform functional MRI (fMRI). The performance of the PET insert was evaluated according to the National Electrical Manufacturers Association (NEMA) standard. The noise equivalent count rate (NEC) peaked at 30.7 × 10(3) counts/s at 7.3 kBq/mL. The point source sensitivity was greater than 7 %. The spatial resolution in the centre field of view was less than 3 mm. Patient data sets clearly revealed a noticeably good PET and MR image quality. PET and MRI phantom tests and first patient data exhibit the device's potential for simultaneous multiparametric imaging. • Combination of PET and MRI is a new emerging imaging technology. • Evaluated brain PET/MRI enables uncompromised imaging performance. • PET/MRI aims to provide multiparametric imaging allowing acquisition of morphology and metabolism.

Similar Papers
  • Research Article
  • Citations22

MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system

  • Apr 30, 2018
  • Physics in Medicine & Biology
  • Negar Omidvari +5
  • Research Article

Medical Imaging

  • Sep 01, 2006
  • BioTechniques
  • Lynne Lederman
  • Conference Article
  • Citations1

Evaluation of scatter fraction and count rate performance of two small-animal PET scanners using dedicated phantoms

  • Oct 01, 2011
  • Rameshwar Prasad +1
  • PDF
  • Research Article
  • Citations4

RF-Penetrable PET insert for simultaneous PET/MR imaging.

  • Jul 29, 2014
  • EJNMMI Physics
  • Brian J Lee +3
  • Research Article
  • Citations2

Towards efficient Monte Carlo N-Particle simulation of a positron emission tomography (PET) via source volume definition

  • Aug 23, 2022
  • Applied Radiation and Isotopes
  • Nazreen Waeleh +5
  • Research Article
  • Citations5

Image quality of Zr-89 PET imaging in the Siemens microPET Focus 220 preclinical scanner.

  • Oct 22, 2015
  • Molecular Imaging and Biology
  • Tyler J Bradshaw +5
  • PDF
  • Research Article
  • Citations38

A 3D MR-acquisition scheme for nonrigid bulk motion correction in simultaneous PET-MR.

  • Jul 25, 2014
  • Medical Physics
  • Christoph Kolbitsch +3
  • Conference Article
  • Citations8

Parametric design study of a long axial field-of-view PET scanner using a block-detector tomograph simulation of a cylindrical phantom

  • Oct 01, 2009
  • W.C.J Hunter +4
  • Research Article

Development of a Body Shield for Small Animal PET System to Reduce Random and Scatter Coincidences

  • Feb 01, 2015
  • IEEE Transactions on Nuclear Science
  • Yasuhiro Wada +2
  • Conference Article

Investigating a re-configurable PET system design

  • Oct 01, 2010
  • Chien-Min Kao +2
  • Conference Article
  • Citations1

Four-layer DOI detector with a multi pixel APD by light sharing method for small animal PET

  • Jan 01, 2007
  • Fumihiko Nishikido +8
  • Research Article
  • Citations119

Design and evaluation of the MAMMI dedicated breast PET

  • Aug 15, 2012
  • Medical Physics
  • L Moliner +12
  • Conference Article
  • Citations2

A phantom design and assessment of lesion detectability in PET imaging

  • Mar 10, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Scott D Wollenweber +2
  • Research Article

Timing performance evaluation of a dual-Axis rotational PET system according to NEMA NU 4-2008 standards: A simulation study

  • Apr 07, 2025
  • Biomedical Physics & Engineering Express
  • P M C C Encarnação +3
  • Research Article
  • Citations29

Recovery of inter-detector and inter-crystal scattering in brain PET based on LSO and GAGG crystals

  • Sep 23, 2020
  • Physics in Medicine & Biology
  • Seungeun Lee +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.