• Home
  • Search
  • TH-B-I-609-01: Imaging Ultrasound Contrast Agents
  • https://doi.org/10.1118/1.1998620Copy DOI Icon

TH-B-I-609-01: Imaging Ultrasound Contrast Agents

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Purpose: Existing Dopplerultrasound techniques are capable of detecting blood flow in large vessels with velocities high enough (>3 cm/sec) to enable removal of tissue signals. Microbubbleultrasound contrast agents can be administered intravenously to increase the backscatter from blood. The nonlinear behavior of ultrasound contrast agents enable discrimination from tissue both nearly stationary microbubbles in the microcirculation and higher velocitymicrobubbles in the larger vasculature. The visualization of blood flow in both the macro‐ and micro‐circulation has been used to assess organ function and characterize tumors. Method and Materials:Imaging techniques for ultrasound contrast agents have been developed utilizing both the nonlinear and transient nature of contrast agents. These techniques are based on detecting microbubble nonlinear responses to the acoustic field of diagnosticultrasound. Different multi‐pulse transmit sequences will be described that have been used detect the nonlinear activity of the microbubbles (harmonic imaging, pulse inversion, amplitude modulation, and coded excitation). Only low amplitude acoustic fields may be used for interrogation to avoid bubble destruction and enable continuous contrast agent imaging. The difficulties of detecting nonlinear activity with low excitations are addressed. Dopplerimaging techniques are used in cases where transient properties of contrast agents are to be imaged. With these techniques high acoustic amplitude is used to intentionally destroy the contrast microbubbles and form an image. Once the bubbles in a region are destroyed, the user must wait for the area to be replenished before forming another image or move to a new imaging plane. Results: While destruction techniques have an excellent signal to noise ratio (SNR), clinical use is difficult due to the destruction of contrast agent. Nonlinear imaging techniques are clinically easier to use, but suffer from SNR and are often penetration limited. A number of different ultrasound contrast agents have been approved for clinical use in Europe and Asia and are in the Federal Drug Administration approval process in the US. Most these contrast agents can be imaged in real‐time using the nonlinear imaging techniques. Conclusion:Ultrasound contrast agents can be used to imageblood flow in both the micro‐ and macro‐ circulations. Clinical examples of imagingultrasound contrast agent with both low and high amplitude techniques will be presented for both radiology and cardiology applications.

Similar Papers
  • Research Article
  • Citations208

Imaging with ultrasound contrast agents: current status and future.

  • Mar 05, 2018
  • Abdominal Radiology
  • Wui K Chong +2
  • Research Article
  • Citations30

Use of Contrast-Enhanced Ultrasonography in Musculoskeletal Medicine

  • May 01, 2012
  • American Journal of Physical Medicine & Rehabilitation
  • Ke-Vin Chang +3
  • Conference Article
  • Citations2

Amplitude modulation and baseband delay-multiply-and-sum beamforming for improved vessel visualization with volumetric contrast-enhanced ultrasound

  • Oct 10, 2022
  • Megan Yociss +3
  • Research Article
  • Citations16

In-vitro-Vergleich eines Ultraschallkontrastmittels der 1. mit einem der 2. Generation für die Refluxdiagnostik

  • Jul 16, 2007
  • RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
  • J Robrecht +1
  • Research Article
  • Citations2

ガラクトース製剤の懸濁液(Levovist,Schering AG)を用いた経頭蓋超音波検査によるPerfusion Imageについて

  • Jan 01, 2002
  • Neurosonology
  • Hideyo Kamada +3
  • Conference Article
  • Citations11

Quadratic Pulse Inversion Ultrasonic Imaging (QPI): Detection of Low-level Harmonic Activity of Microbubble Contrast Agents

  • Mar 18, 2005
  • M.F Al-Mistarihi +1
  • Conference Article
  • Citations2

Pulse inversion Doppler for blood flow detection in the macro- and microcirculation

  • Oct 05, 2003
  • M Bruce +4
  • Research Article
  • Citations63

Renal cortical perfusion in rabbits: visualization with color amplitude imaging and an experimental microbubble-based US contrast agent.

  • Oct 01, 1996
  • Radiology
  • G A Taylor +2
  • Research Article
  • Citations13

Pediatric contrast-enhanced ultrasound in the United States: a survey by the Contrast-Enhanced Ultrasound Task Force of the Society for Pediatric Radiology.

  • Feb 13, 2018
  • Pediatric Radiology
  • Susan J Back +13
  • Research Article
  • Citations164

Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion: preliminary experience.

  • May 01, 1998
  • Radiology
  • T Albrecht +7
  • Supplementary Content
  • Citations171

Voiding urosonography with ultrasound contrast agents for the diagnosis of vesicoureteric reflux in children

  • Jul 06, 2007
  • Pediatric Radiology
  • Kassa Darge
  • Research Article
  • Citations6

Ultrasound contrast agents can influence the respiratory burst activity of human neutrophil granulocytes

  • Jan 01, 2004
  • Ultrasound in Medicine & Biology
  • Grigorios Korosoglou +6
  • Research Article
  • Citations130

Functional and Molecular Ultrasound Imaging: Concepts and Contrast Agents

  • Feb 01, 2009
  • Current Medicinal Chemistry
  • F Kiessling +2
  • Research Article
  • Citations116

Harmonic voiding urosonography with a second-generation contrast agent for the diagnosis of vesicoureteral reflux

  • Dec 19, 2008
  • Pediatric Radiology
  • Frederica Papadopoulou +5
  • Research Article
  • Citations77

From Anatomy to Functional and Molecular Biomarker Imaging and Therapy: Ultrasound Is Safe, Ultrafast, Portable, and Inexpensive.

  • Jun 17, 2020
  • Investigative Radiology
  • Shiying Wang +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.