• Home
  • Search
  • TH‐C‐144‐03: Tissue Decomposition From Dual Energy CT Data to Reduce Range Uncertainties in Proton and Carbon Radiotherapy
  • https://doi.org/10.1118/1.4815797Copy DOI Icon

TH‐C‐144‐03: Tissue Decomposition From Dual Energy CT Data to Reduce Range Uncertainties in Proton and Carbon Radiotherapy

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Purpose: To reduce uncertainties in CT data conversion to stopping power ratio (SPR) and tissue composition when using single energy CT (SECT), this study presents a first approach of exploiting dual energy CT (DECT) data for Monte Carlo (MC) based dose calculation in particle therapy. Methods: DECT image data can be converted into an electron density and effective atomic number image. With both tissue parameters elemental weights of 71 tabulated tissues were predicted by dedicated linear fits for each element. The mass density was derived via a single linear fit of the electron density from adipose on. Dose calculations with the MC system TOPAS were performed using monoenergetic pencil beams (protons and carbons) stopped in 12 selected tissues which showed considerable differences in composition predictions from single and dual energy CT. Ranges were compared with predictions from the novel DECT approach and the standard SECT. Results: Predictions of mass density, carbon and oxygen elemental weights profit highly from the additional DECT information. Maximum differences to the true mass density could be reduced from 3.0% (SECT) to 0.9% (DECT) for soft tissue and from 0.7% (SECT) to 0.1% (DECT) for bone tissue. Furthermore, DECT shows a significant improvement also in common tissues: range uncertainties in cartilage were reduced from 1.7% (SECT) to 0.2% (DECT), in yellow marrow from 1.7% (SECT) to 0.5% (DECT), in liver from 0.9% (SECT) to 0.2% (DECT), in brain cerebroisal fluid from 2.2% (SECT) to 0.0% (DECT) and in femur the predicted range deviates by 0.8% (SECT) to 0.0% (DECT) from the true value. Conclusion: DECT can provide more accurate material compositions and mass density as compared to single energy CT. Therewith, DECT information can significantly reduce range uncertainties in particle therapy and can lead to a reduction in currently applied range margins in proton and carbon ion therapy.

Similar Papers
  • Research Article
  • Citations4

Comparison of radiation exposure from dual- and single-energy CT imaging protocols resulting in equivalent contrast-to-noise ratio of lesions for adults and children: a phantom study.

  • Dec 18, 2024
  • European radiology
  • Nikos Ntoufas +3
  • Research Article

SU‐F‐J‐195: On the Performance of Four Dual Energy CT Formalisms for Extracting Proton Stopping Powers

  • Jun 01, 2016
  • Medical Physics
  • E Baer +3
  • Research Article
  • Citations16

Learning-based synthetic dual energy CT imaging from single energy CT for stopping power ratio calculation in proton radiation therapy.

  • Oct 28, 2021
  • The British Journal of Radiology
  • Serdar Charyyev +9
  • Research Article
  • Citations4

Initial Validation of Proton Dose Calculations on SPR Images from DECT in Treatment Planning System.

  • Sep 01, 2020
  • International journal of particle therapy
  • Sina Mossahebi +6
  • Research Article
  • Citations14

Evaluation of dual energy CT and iterative metal artefact reduction (iMAR) for artefact reduction in radiation therapy

  • Oct 10, 2019
  • Australasian Physical & Engineering Sciences in Medicine
  • P Lim +2
  • Research Article
  • Citations7

Real-time diagnosis of intracerebral hemorrhage by generating dual-energy CT from single-energy CT

  • May 07, 2024
  • Medical image analysis
  • Caiwen Jiang +4
  • Abstract

Abstract ID: 114 The impact of dual-energy CT tissue segmentation for low-dose rate prostate brachytherapy Monte Carlo dose calculations

  • Oct 01, 2017
  • Physica Medica
  • Charlotte Remy +2
  • Research Article
  • Citations9

Diagnostic value of quantitative parameters for myocardial perfusion assessment in patients with suspected coronary artery disease by single- and dual-energy computed tomography myocardial perfusion imaging.

  • Feb 01, 2021
  • IJC Heart & Vasculature
  • Aroa Ruiz-Muñoz +12
  • Research Article
  • Citations3

Artificial intelligence-based image-domain material decomposition in single-energy computed tomography for head and neck cancer.

  • Jan 14, 2024
  • International journal of computer assisted radiology and surgery
  • Yuhei Koike +6
  • Research Article
  • Citations7

Improving image quality of triple-low-protocol renal artery CT angiography with deep-learning image reconstruction: a comparative study with standard-dose single-energy and dual-energy CT with adaptive statistical iterative reconstruction

  • Jan 23, 2024
  • Clinical radiology
  • Z Meng +9
  • Research Article
  • Citations6

Accuracy of Dual-Energy Computed Tomography Techniques for Fat Quantification in Comparison With Magnetic Resonance Proton Density Fat Fraction and Single-Energy Computed Tomography in an Anthropomorphic Phantom Environment.

  • Sep 01, 2021
  • Journal of Computer Assisted Tomography
  • Zi Jun Wu +6
  • Research Article
  • Citations53

Ion range estimation by using dual energy computed tomography

  • Apr 15, 2013
  • Zeitschrift für Medizinische Physik
  • Nora Hünemohr +6
  • Research Article
  • Citations6

Assessment of the impact of CT calibration procedures for proton therapy planning on pediatric treatments

  • Jul 20, 2021
  • Medical Physics
  • Esther Bär +7
  • Research Article
  • Citations19

Head and neck multi-organ segmentation on dual-energy CT using dual pyramid convolutional neural networks

  • May 20, 2021
  • Physics in Medicine & Biology
  • Tonghe Wang +8
  • Research Article
  • Citations5

Prediction of proton stopping power ratios using dual-energy CT basis material decomposition.

  • Jan 09, 2024
  • Medical Physics
  • Erik Pettersson +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.