The influence of the dwell time deviation constraint (DTDC) parameter on dosimetry with IPSA optimisation for HDR prostate brachytherapy.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To investigate how the dwell time deviation constraint (DTDC) parameter, applied to inverse planning by simulated annealing (IPSA) optimisation limits large dwell times from occurring in each catheter and to characterise the effect on the resulting dosimetry for prostate high dose rate (HDR) brachytherapy treatment plans. An unconstrained IPSA optimised treatment plan, using the Oncentra Brachytherapy treatment planning system (version 4.3, Nucletron an Elekta company, Elekta AB, Stockholm, Sweden), was generated for 20 consecutive HDR prostate brachytherapy patients, with the DTDC set to zero. Successive constrained optimisation plans were also created for each patient by increasing the DTDC parameter by 0.2, up to a maximum value of 1.0. We defined a "plan modulation index", to characterise the change of dwell time modulation as the DTDC parameter was increased. We calculated the dose volume histogram indices for the PTV (D90, V100, V150, V200%) and urethra (D10%) to characterise the effect on the resulting dosimetry. The average PTV D90% decreases as the DTDC is applied, on average by only 1.5 %, for a DTDC = 0.4. The measures of high dose regions in the PTV, V150 and V200%, increase on average by less than 5 and 2 % respectively. The net effect of DTDC on the modulation of dwell times has been characterised by the introduction of the plan modulation index. DTDC applied during IPSA optimisation of HDR prostate brachytherapy plans reduce the occurrence of large isolated dwell times within individual catheters. The mechanism by which DTDC works has been described and its effect on the modulation of dwell times has been characterised. The authors recommend using a DTDC parameter no greater than 0.4 to obtain a plan with dwell time modulation comparable to a geometric optimised plan. This yielded on average a 1.5 % decrease in PTV coverage and an acceptable increase in V150%, without compromising the urethral dose.

Similar Papers
  • Research Article

MO-E-BRB-03: High Dose Rate Brachytherapy Optimization Based on the Generalized Equivalent Uniform Dose

  • Jun 01, 2010
  • Medical Physics
  • D Giantsoudi +5
  • Research Article
  • Citations6

A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy.

  • Jun 17, 2021
  • Physical and engineering sciences in medicine
  • Yousif A M Yousif +2
  • Research Article
  • Citations9

A manual algorithm for computing dwell times for two-catheter endobronchial treatments using HDR brachytherapy.

  • May 01, 2000
  • Medical physics
  • Gary A Ezzell
  • Research Article

SU-E-T-428: Class Solution for Prostate High Dose Rate Brachytherapy with Inverse Planning Simulated Annealing.

  • Jun 01, 2012
  • Medical physics
  • N Sheth +3
  • Research Article
  • Citations15

High resolution small-scale inorganic scintillator detector: HDR brachytherapy application.

  • Mar 01, 2021
  • Medical Physics
  • Sree Bash Chandra Debnath +6
  • Abstract
  • Citations3

An Analysis of Learning Curve Effect on the Speed and Quality of High Dose Rate Prostate Brachytherapy Procedures

  • Oct 23, 2020
  • International Journal of Radiation Oncology*Biology*Physics
  • D Coupal +17
  • Research Article
  • Citations114

High dose rate afterloading intraluminal brachytherapy in malignant airway obstruction of lung cancer

  • Feb 01, 1994
  • International Journal of Radiation Oncology*Biology*Physics
  • Li-Fen L Chang +3
  • Abstract
  • Citations1

Automated Plan Checks in High Dose Rate Prostate Brachytherapy Using Custom Scripts in a Commercially Available Spreadsheet Application

  • Sep 23, 2017
  • International Journal of Radiation Oncology*Biology*Physics
  • D.M Giles +3
  • Research Article
  • Citations6

Development of a method for treating lower-eyelid carcinomas using superficial high dose rate brachytherapy.

  • Oct 29, 2020
  • Physical and Engineering Sciences in Medicine
  • H Stephens +3
  • Research Article

SU-E-T-351: Pre-Treatment Simulation Tolerance and Dosimetry Effects On OARs for the Cylinder High Dose Rate (HDR) Brachytherapy Treatment of Vaginal Cuff Cancer

  • Jun 01, 2013
  • Medical Physics
  • C Shi +2
  • Research Article
  • Citations20

Dosimetric verification of a high dose rate brachytherapy treatment planning system in homogeneous and heterogeneous media

  • Feb 18, 2012
  • Physica Medica
  • S.C Uniyal +2
  • Abstract

PP03 Presentation Time: 9:20 AM: Patterns of Failure for Salvage HDR Prostate Brachytherapy in the Prostate PET Imaging Era

  • Nov 01, 2022
  • Brachytherapy
  • Daniel Benjamin Rosen +5
  • Research Article

SU‐E‐T‐68: A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy

  • Jun 01, 2015
  • Medical Physics
  • Y Ueda +8
  • Abstract

Genitourinary Toxicity In Prostate Cancer Patients With History Of Transurethral Resection Of The Prostate Undergoing High Dose Rate Brachytherapy With A Novel Urethral-Sparing Technique

  • Oct 23, 2020
  • International Journal of Radiation Oncology*Biology*Physics
  • J Chew +4
  • Research Article

Updated results of MR-assisted focal salvage HDR prostate brachytherapy: a prospective study.

  • Oct 01, 2025
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
  • Gregory Paulin +13
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.