• Home
  • Search
  • The open-source multi-wavelength non-invasive blood glucose sensing system.
  • https://doi.org/10.1038/s41598-025-28673-4Copy DOI Icon

The open-source multi-wavelength non-invasive blood glucose sensing system.

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Diabetes treatment requires reliable blood glucose monitoring to allow for appropriate adjustments and interventions. The conventional finger-prick test is associated with significant discomfort and poor compliance, highlighting the critical need for non-invasive, user-friendly solutions. This study proposes and validates an open-source, multi-wavelength spectroscopy system that combines visible (660nm) and near-infrared (940nm) wavelengths through six distinct transmission and reflection strategies. The system was validated through a rigorous three-phase process. Phase I established a preliminary regression model against a commercial meter using 500 controlled samples ([Formula: see text] up to 0.8832). Phase II expanded this validation in 96 healthy volunteers, confirming high clinical acceptability (over 95% in Zone A, Clarke Error Grid) and a mean absolute error of 8.438mg/dL relative to the commercial device. Critically, Phase III performed a definitive clinical validation, comparing our system and the commercial meter against the venous plasma glucose (VPG) gold standard. This analysis definitively established the clinical failure of all reflection-based strategies (resulting in Zone D errors), while confirming 100% clinical safety (Zones A/B) for all transmission modes. Notably, our multi-wavelength transmission (MT) strategy achieved 100% Zone A accuracy and demonstrated superior analytical precision (tighter ISO15197:2015 compliance) than the ISO-compliant commercial benchmark when both were compared to the VPG. This work validates a transparent, open-source platform as a clinically reliable and accurate non-invasive alternative for intermittent glucose monitoring.

Similar Papers
  • Research Article
  • Citations1

Self-monitoring of blood glucose

  • Feb 01, 2012
  • International Journal of Clinical Practice
  • Satish K Garg +1
  • Research Article
  • Citations7

Blood Glucose Monitoring: Necessary and Sufficient?

  • Sep 01, 2007
  • Journal of Diabetes Science and Technology
  • Barry H Ginsberg
  • Research Article
  • Citations1

Development and application of continuous and noninvasive glucose monitoring technology

  • Nov 11, 2019
  • Chinese Journal of Laboratory Medicine
  • Junling Tang +1
  • Research Article
  • Citations109

Optical Coherence Tomography-Based Continuous Noninvasive Glucose Monitoring in Patients with Diabetes

  • Jun 01, 2008
  • Diabetes Technology & Therapeutics
  • Robert A Gabbay +1
  • Research Article
  • Citations4

Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion.

  • May 07, 2014
  • Journal of clinical monitoring and computing
  • Anant Khositseth +4
  • Research Article
  • Citations6

Noninvasive Real-Time Glucose Monitoring Is in the Near Future.

  • Sep 01, 2024
  • Diabetes technology & therapeutics
  • Irl B Hirsch +2
  • Research Article

Non invasive blood glucose estimation using green light photoplethysmography and machine learning.

  • Feb 17, 2026
  • Frontiers in digital health
  • Khadija Khan +4
  • Research Article
  • Citations24

Evaluation of a Continuous Blood Glucose Monitor: A Novel and Non-Invasive Wearable Using Bioimpedance Technology.

  • Oct 29, 2021
  • Journal of Diabetes Science and Technology
  • Farid Sanai +10
  • Research Article
  • Citations26

The influence of glucose self-monitoring on glycaemic control in patients with diabetes mellitus in Sudan

  • Apr 18, 2006
  • Diabetes Research and Clinical Practice
  • M Abdelgadir +3
  • Conference Article
  • Citations16

Non-invasive Blood Glucose Monitoring and Data Analytics

  • May 19, 2017
  • Melissa Eadie +1
  • Research Article
  • Citations3

Clinical application of real-time continuous glucose monitoring system during postoperative enteral nutrition therapy in esophageal cancer patients.

  • Mar 24, 2024
  • Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition
  • Ranran Zhang +9
  • Research Article
  • Citations6

Noninvasive Continuous Glucose Monitoring Using Multimodal Near-Infrared, Temperature, and Pressure Signals on the Earlobe.

  • Jun 24, 2025
  • Biosensors
  • Jongdeog Kim +4
  • Research Article
  • Citations17

A review of non-invasive blood glucose monitoring through breath acetone and body surface

  • May 21, 2024
  • Sensors and Actuators: A. Physical
  • He Liu +4
  • Research Article
  • Citations3

Diagnostic performance of 2 h postprandial capillary and venous glucose as a screening test for abnormal glucose tolerance

  • Apr 25, 2012
  • Primary Care Diabetes
  • Sauwanan Bumrerraj +4
  • Research Article
  • Citations12

Flash glucose monitoring in type1 diabetes: A comparison with self-monitoring blood glucose.

  • Mar 02, 2020
  • Journal of diabetes investigation
  • Naru Babaya +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.