The risks of pedicle wall breech with larger screws after undertapping
Yes, We CAN!
Yes, We CAN!
The medial cortical pedicle screw—a new technique for cervical pedicle screw placement with partial drilling of medial cortex
The medial cortical pedicle screw—a new technique for cervical pedicle screw placement with partial drilling of medial cortex
Read moreAccuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make?
The use of thoracic pedicle screws for the treatment of adolescent idiopathic scoliosis (AIS) has gained widespread popularity. However, the placement of pedicle screws in the deformed spine poses unique challenges, and surgeons experience a learning curve. The in vivo accuracy as determined by computed tomography (CT) of placement of thoracic pedicle screws in the deformed spine as a function of surgeon experience is unknown. We undertook a retrospective review to determine the effect of surgeon experience on the accuracy of thoracic pedicle screw placement in AIS. In 2005, we started to obtain routine postoperative CT scans on patients undergoing a spinal fusion. From a database of these patients, we selected AIS patients, who underwent a posterior spinal fusion. Fifteen consecutive patients for each of the following three groups stratified by attending surgeon experience were selected (N = 45): A) less than 20 cases of all pedicle screw constructs for AIS (surgeons <2 years of practice), B) 20-50 cases (surgeons 2-5 years of practice), and C) greater than 50 cases (surgeons greater than 5 years of practice). Intraoperative evaluation of all screws included probing of the pedicle screw tract, neurophysiologic monitoring, and fluoroscopic confirmation. A total of 856 thoracic pedicle screws were studied. Postoperative CT scans were evaluated by two spine surgeons and a consensus read established as follows: (1) In: intraosseous placement or <or=2-mm breach, (2) Out: >2-mm breach, either medial or lateral. Of the 856 screws, 104 demonstrated a >2-mm breach, for an overall rate of 12.1% (medial = 55, lateral = 49, P = 0.67). When the breach rates were stratified by surgeon experience, there was a trend toward decreased rate of breach for the most experienced surgeons, although this did not attain statistical significance (Group A: 12.7%, Group B: 12.9%, Group C: 10.8%, P = 0.58). However, the most experienced group (C) had a markedly decreased rate of medial breaches (3.5 vs. 7.4% and 8.4% for groups A and B, respectively, P < 0.01). The breach rate for the concave periapical screws was not statistically different from the overall breach rate (13.0% vs. 12.1%, P = 0.93). In conclusion, the overall accuracy of placement of pedicle screws in the deformed spine was 87.9%, with no neurologic, vascular, or visceral complications. Meticulous technique allows spine surgeons with a range of surgical experience to accurately and safely place thoracic pedicle screws in the deformed spine. The most experienced surgeons demonstrated the lowest rate of medial breaches.
Read moreIntraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
BackgroundPercutaneous pedicle screw (PPS) placement is a key step in several minimally invasive spinal surgery (MISS) procedures. Traditional technique for PPS makes use of C-arm fluoroscopy assistance (FA). More recently, newer intraoperative imaging techniques have been developed for PPS, including CT-guided navigation (CTNav). The aim of this study was to compare FA and CTNav techniques for PPS with regard to accuracy, complications, and radiation dosage.Materials and methodsA total of 192 patients with degenerative lumbar spondylolisthesis and canal stenosis who underwent MISS posterior fusion ± interbody fusion through transforaminal approach (TLIF) were retrospectively reviewed. Pedicle screws were placed percutaneously using either standard C-arm fluoroscopy guidance (FA group) or CT navigation (CTNav group). Intraoperative effective dose (ED, mSv) was measured. Screw placement accuracy was assessed postoperatively on a CT scan using Gertzbein and Robbins classification (grades A–E). Oswestry disability index (ODI) and visual analog scale (VAS) scores were compared in both groups before and after surgery.ResultsA total of 101 and 91 procedures were performed with FA (FA group) and CTNav approach (CTNav group), respectively. Median age was 61 years in both groups, and the most commonly treated level was L4–L5. Median ED received from patients was 1.504 mSv (0.494–4.406) in FA technique and 21.130 mSv (10.840–30.390) in CTNav approach (p < 0.001). Percentage of grade A and B screws was significantly higher for the CTNav group (96.4% versus 92%, p < 0.001), whereas there were 16 grade E screws in the FA group and 0 grade E screws in the CTNav group (p < 0.001). A total of seven and five complications were reported in the FA and CTNav group, respectively (p = 0.771).ConclusionsCTNav technique increases accuracy of pedicle screw placement compared with FA technique without affecting operative time. Nevertheless, no significant difference was noted in terms of reoperation rate due to screw malpositioning between CTNav and FA techniques. Radiation exposure of patients was significantly higher with CTNav technique.Level of Evidence: Level 3.
Read more35. How many screws are necessary to be considered an experienced surgeon for freehand placement of thoracolumbar pedicle screws? Analysis of the learning curve using the cumulative summation test for learning curve (LC-CUSUM)
35. How many screws are necessary to be considered an experienced surgeon for freehand placement of thoracolumbar pedicle screws? Analysis of the learning curve using the cumulative summation test for learning curve (LC-CUSUM)
Read moreSpinal stability with anterior or posterior ray threaded fusion cages.
The authors conducted a study to determine if the rigidity supplied to the spine by posterior placement of the Ray threaded fusion cage (TFC) is further enhanced by the placement of pedicle screws and, additionally, if bilateral anteriorly placed TFCs render the spine more rigid than a single anteriorly placed TFC. Ten human cadaveric spinal specimens (L2-S1) were affixed within a testing frame. Loads of 1.5, 3, 4.5, and 6 Nm were applied to the spine in six degrees of freedom: flexion-extension, right and left lateral bending, and right and left axial rotation. Motion in an x, y, and z cartesian axis system was tracked using dual video cameras following light-emitting diodes attached to the spine and base plate. Load testing of the spines was performed in the intact mode, following which the spinal segments were randomized to receive anterior or posterior instrumentation. In five spine specimens we performed posterior discectomy, posterior lumbar interbody fusion (PLIF) with placement of femoral rings and pedicle screws, PLIF with bilateral TFCs, and bilateral TFCs with pedicle screws. Five other spines underwent anterior-approach discectomy, followed by implantation of a unilateral cage and bilateral cages. Load testing was performed after each step. Spines in which PLIF with pedicle screws and TFCs with pedicle screws were placed were more rigid than after discectomy in all directions of motion except flexion. Anterior discectomy provided significantly (p < or = 0.05) less stability in left and right axial rotation than the intact spines and following posterior discectomy. Following anterior implantation of bilateral TFCs, spines were significantly more rigid than after discectomy in all directions except extension.
Read moreO-Arm Assisted Cervicothoracic Spine Pedicle Screw Placement Accuracy Is Higher Than C-Arm Fluoroscopy
O-Arm Assisted Cervicothoracic Spine Pedicle Screw Placement Accuracy Is Higher Than C-Arm Fluoroscopy
The Learning Curve of Pedicle Screw Placement
A retrospective study. Assess the learning curve of pedicle screw (PS) placement of a Spinal Surgery Fellow (SSF) with no previous experience with the technique. Recent studies have attempted to identify the learning curve for different surgical procedures to define training requirements. Several authors have described a learning curve for PS placement. However, no one has defined the number of PS necessary to be competent in this skill. All patients who had PS inserted by the SSF under the supervision of an Attending Spinal Consultant (ASC) and had adequate postoperative radiographs and computed tomography scans available, were included in this study. PS position was assessed by 2 blinded independent observers using a grading scale. PS placement by the SSF was evaluated by examining the assessed position in chronological groups of 40 screws. RESULTS.: Ninety-four patients underwent internal fixation of the spine with 582 PS. Eight cases (40 screws) were excluded because of lack of imaging studies. Of the 542 screws under evaluation, 320 (59%) were performed by the SSF, 187 (34.5%) by the ASC, and 35 (6.5%) by advanced orthopedic or neurosurgical trainees.The rate of misplaced PS performed by the SSF for the first 80 PS was 12.5% and dropped to 3.4% for the remaining 240 screws, which is a statistically significant difference (P < 0.01). Evaluation of computed tomography of vertebrae with PS placed by the SSF on one side and by the ASC on the other showed that the ASC achieved better placement during the first 80 PS (P < 0.01). However, this difference disappeared in the last 240 (P = 1.00). The findings demonstrate a learning curve for PS placement. In this series, the asymptote for this technique for an inexperienced SSF, started after about 80 screws (approximately 25 cases).
Read morePlacement of pedicle screws using three-dimensional fluoroscopy-based navigation in lumbar vertebrae with axial rotation
Despite potential advantages of three-dimensional fluoroscopy-based navigation, there still remain a lot of controversies about the indications of this technology, especially whether it is worthy of being used in placement of pedicle screws in lumbar spine. However, according to the inconsistent conclusions reported in the literature and our experiences, the traditional method relying on anatomical landmarks and fluoroscopic views to guide lumbar pedicle screw insertion is unable to meet the requirement of precise screw placement. Based on our observation, screw malposition seems to occur concomitant with vertebral axial rotation which is a ubiquitous phenomenon. Three-dimensional fluoroscopy-based navigation can provide the most valuable axial images in real-time, so it may be useful for placement of pedicle screws in lumbar spine. This study was intended to evaluate the effect of axial rotation of lumbar vertebrae on the accuracy of pedicle screw placement using the traditional method, as well as assess the value of three-dimensional fluoroscopy-based navigation in improving the accuracy. Sixteen lumbar simulation models at different degrees of axial rotation (0°, 5°, 10°, and 20°), with every four assigned the same degree, were equally divided into two groups (traditional method group and three-dimensional fluoroscopy-based navigation group). Random placement of pedicle screws was carried out, followed by CT scan postoperatively. Then the outer pedicle cortex contours were depicted from reconstructed sectional pedicle images using Photoshop. The accuracy of pedicle screw placement was evaluated by determining the interrelationship between screw trajectory and pedicle cortex (quality), and measuring the shortest distance from pedicle screw axis to outer cortex of the pedicle (quantity). Eighty pedicle screws were implanted, respectively, in each group. In traditional method group, statistical difference existed in the accuracy of pedicle screw placement at different axial rotational degrees (P < 0.05). With degrees increasing, the accuracy declined. The accuracy of three-dimensional fluoroscopy-based navigation group was higher than traditional method group in vertebrae with axial rotation (P < 0.01). In qualitative evaluation, the accuracy of the two methods had statistical difference when the degree was 20°, and in quantitative evaluation, statistical difference existed in 5°, 10°, and 20° of vertebral axial rotation.
Read morePedicle screw pullout strength. Correlation with insertional torque.
This study was designed to correlate several parameters regarding pedicle screw bone/metal interface strength. The insertional torque measured during tapping and placement of pedicle screws was correlated with the bone mineral density of the vertebral body, the dimensions of the pedicle, the method of preparation of the pedicle, and the amount of load and number of cycles to failure of the bone/metal interface. Thirty human cadaveric lumbar vertebrae were instrumented with 6.5-mm pedicle screws. The maximum torque achieved during insertion was digitally recorded. A cyclic pedicle screw pullout test was performed. A linear correlation existed between both the insertional torque when tapping or when inserting a screw and the number of cycles to ultimate pedicle screw pullout. An inverse linear relationship was found between the pedicle width and cycles to failure. There was no linear correlation found when comparing the number of cycles to failure to bone mineral density. These findings suggest that insertional torque is a good predictor of bone-metal interface failure. Bone mineral density of the vertebral body was less effective as a predictor of failure. Smaller pedicle width correlated with increased insertional torque and cycles to failure. This may explain why patients with osteoporosis on radiography may still obtain stable fixation with pedicle screws. Other factors, such as pedicle dimensions and shape, affect screw purchase as much as vertebral body bone density. Insertional torque less than 4.0 inch-pounds led to early pedicle screw pullout. This study forms the basis for the authors' clinical use of an instrumented torque screwdriver to measure insertional torque in the operating room.
Read moreDoes Navigation Improve Accuracy of Placement of Pedicle Screws in Single-level Lumbar Degenerative Spondylolisthesis?
This was a prospective, nonrandomized study. To assess the accuracy of O-arm navigation-based pedicle screw insertion in lumbar degenerative spondylolisthesis and to compare it with free-hand pedicle screw insertion technique in matched population. O-arm navigation is latest in navigation technology that can provide real-time intraoperative images in 3 dimensions while placing the pedicle screws to improve intraoperative pedicle screw accuracy. Degenerative lumbar spondylolisthesis is a locally unstable pathology and placement of pedicle screws can cause increased rotation and translation of the vertebral body. However, is this motion detected by the tracker placed across the unstable segment, is a matter of debate. Inability to detect these positional changes can lead to pedicle perforation while inserting screws using navigation. No study has evaluated the role of O-arm navigation in this patient population. The study population was divided into 2 groups with 19 patients each, one comprising patients who underwent O-arm navigation-based pedicle screw insertion (group 1) and the other comprising patients who underwent free-hand pedicle screw insertion technique (group 2). A total of 152 pedicle screws were implanted in 38 patients for 1-level instrumented fusion for degenerative lumbar spondylolisthesis. Intraoperative 3-dimensional computed tomography scans using the O-arm were obtained for all patients after insertion of pedicle screws. The images were reviewed intraoperatively and postoperatively for the analysis of pedicle breaches. Assessments in either of the group included (i) accuracy of placement of screws; (ii) the rate and direction of perforation; and (iii) the number of segments the perforated screw was away from the navigation tracker. Mean age of patients in group 1 (O-arm navigation-assisted) was 60 years (SD 11.25; range, 37-73 y), whereas in group 2 (free-hand pedicle screw) was 62 years (SD 18.07; range, 36-90 y). Overall anatomic perforation rate was 12.5% (19/152). Individually, group 1 had 14.47% (11/76) of perforations in comparison with 10.53% (8/76) observed in group 2. The difference was not statistically significant. The lateral margin was the most common site of perforation in both group 1 (64%, 7/11) and group 2 (62.5%, 5/8). Functional perforation rate for the series was 3.3% (5/152), with group 1 having 2.63% (2/76) and group 2 having 3.95% (3/76). The rate of perforation (PR) was significantly higher statistically when the tracker was placed 3 or more [PR 37.5% (6/16)] spinal segments away from instrumented segment compared with when it was placed 1 (0%) or 2 [PR 13.89% (5/36)] spinal segments away. Overall, 11 screws (11/152, 7.24%) had grade 2 perforations and had to be revised. No neurological complications were observed in the series. O-arm navigation does not provide any significant advantage over conventional free-hand pedicle screw insertion technique in patients with single-level degenerative spondylolisthesis. The accuracy is dependent on the distance of the tracker from the level of instrumentation. Lateral perforations are more common because of instability at the instrumented level leading to translation and rotation of the vertebral body while placing pedicle screws leading to preferential lateral trajectory. These lateral perforations could not be prevented by using navigation. However, no significant complications were noted in either technique.
Read morePredictors of accurate intrapedicular screw placement in single-level lumbar (L4-5) fusion: robot-assisted pedicle screw, traditional pedicle screw, and cortical bone trajectory screw insertion
BackgroundThe superiorities in proximal facet joint protection of robot-assisted (RA) pedicle screw placement and screw implantation via the cortical bone trajectory (CBT) have rarely been compared. Moreover, findings on the screw accuracy of both techniques are inconsistent. Therefore, we analyzed the screw accuracy and incidence of facet joint violation (FJV) of RA and CBT screw insertion in the same study and compared them with those of conventional pedicle screw (PS) insertion. The possible factors affecting screw accuracy and FJV were also analyzed.MethodsA total of 166 patients with lumbar degenerative diseases requiring posterior L4-5 fusion were retrospectively included and divided into the RA, PS, and CBT groups from March 2019 to December 2021. The grades of intrapedicular accuracy and superior FJV were evaluated according to the Gertzbin–Robbins scale and the Babu scale based on postoperative CT. Univariable and multivariable analyses were conducted to assess the possible risk factors associated with intrapedicular accuracy and superior FJV.ResultsThe rates of optimal screw insertion in the RA, PS, and CBT groups were 87.3%, 81.3%, and 76.5%, respectively. The difference between the RA and CBT groups was statistically significant (P = 0.004). Superior FJVs occurred in 28.2% of screws in RA, 45.0% in PS, and 21.6% in CBT. The RA and CBT groups had fewer superior FJVs than the PS group (P = 0.008 and P < 0.001, respectively), and no significant difference was observed between the RA and CBT groups (P = 0.267). Multivariable analysis revealed that the CBT technique was an independent risk factor for intrapedicular accuracy. Furthermore, older age, the conventional PS technique and a smaller facet angle were independently associated with the incidence of superior FJVs.ConclusionsThe RA and CBT techniques were associated with fewer proximal FJVs than the PS technique. The RA technique showed a higher rate of intrapedicular accuracy than the CBT technique. The CBT technique was independently associated with screw inaccuracy. Older age, conventional PS technique and coronal orientation of the facet join were independent risk factors for superior FJV.
Read moreAccuracy and Safety of Percutaneous Lumbosacral Pedicle Screw Placement Using Dual-Planar Intraoperative Fluoroscopy
Study DesignRetrospective case series with prospective arm.PurposeTo assess the safety and accuracy of percutaneous lumbosacral pedicle screw placement (PLPSP) in the lumbosacral spine using intraoperative dual-planar fluoroscopy (DPF).Overview of LiteratureThere are several techniques available for achieving consistent, safe, and accurate results with PLPSP. There is a paucity of literature describing the beneficial operative, economic, and clinical outcomes of DPF, the most readily accessible image guidance system.MethodsFrom 2004 to 2014, 451 consecutive patients underwent PLPSP using DPF, for a total of 2,345 screw placement. The results of prospectively obtained postoperative computed tomography (CT) examinations of an additional 41 consecutive patients were compared with the results of 104 CT examinations obtained postoperatively due to clinical symptomatology; these results were interpreted by three reviewers. The rates of revision indicated by misplaced screws with consistent clinical symptomatology were compared between groups. Pedicle screw placement was graded according to 2-mm increments in medial pedicle wall breach and measurement of screw axis placement.ResultsSeven of the 2,345 pedicle screws placed percutaneously with the use of the dual-planar fluoroscopic technique required revision because of a symptomatic misplaced screw, for a screw revision rate of 0.3%. There were no statistically significant demographic differences between patients who had screws revised and those who did not. All screws registered greater than 10 mA on electromyographic stimulation. In the 41 prospectively obtained CT examinations, one out of 141 screws (0.7%) was revised due to pedicle wall breach; whereas among the 104 patients with 352 screws, three screws were revised (0.9%).ConclusionsDPF is an extremely accurate, safe, and reproducible technique for placement of percutaneous pedicle screws and is a readily available and cost-effective alternative to CT-guided pedicle screw placement techniques. Postoperative CT evaluation is not necessary with PLPSP unless the patient is symptomatic. Acceptable electromyographic thresholds may need to be reevaluated.
Read more39. Optimizing safety in robotic lumbar instrumented fusions: a risk factor analysis of robotic failures
39. Optimizing safety in robotic lumbar instrumented fusions: a risk factor analysis of robotic failures
Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time.
Percutaneous pedicle screws are used to provide rigid internal fixation in minimally invasive spinal procedures and generally require the use of Kirchner wires (or K-wires) as a guide for screw insertion. K-wires can bend, break, advance, or pull out during the steps of pedicle preparation and screw insertion. This can lead to increased fluoroscopic and surgical times and potentially cause neurological, vascular, or visceral injury. The authors present their experience with a novel "K-wireless" percutaneous pedicle screw system that eliminates the inherent risks of K-wire use. A total of 100 screws were placed in 28 patients using the K-wireless percutaneous screw system. Postoperative dedicated spinal CT scans were performed in 25 patients to assess the accuracy of screw placement. Screw placement was graded A through D by 2 independent radiologists: A = within pedicle, B = breach < 2 mm, C = breach of 2-4 mm, and D = breach > 4 mm. Screw insertion and fluoroscopy times were also recorded in each case. Clinical complications associated with screw insertion were documented. A total of 100 K-wireless percutaneous pedicle screws were placed into the lumbosacral spine in 28 patients. Postoperative CT was performed in 25 patients, thus the placement of only 90 screws was assessed. Eighty-seven screws were placed within the pedicle confines (Grade A), and 3 violated the pedicle (2 Grade B [1 lateral, 1 medial] and 1 Grade D [medial]) for an overall accuracy rate of 96.7%. One patient required reoperation for screw repositioning due to a postoperative L-5 radiculopathy secondary to a Grade D medial breach at L-5. This patient experienced improvement of the radiculopathy after reoperation. Average screw insertion and fluoroscopy times were 6.92 minutes and 22.7 seconds per screw, respectively. The results of this study demonstrate that the placement of K-wireless percutaneous pedicle screws is technically feasible and can be performed accurately and safely with short procedure and fluoroscopy times.