• Home
  • Search
  • Three‐dimensional motion corrected sensitivity encoding reconstruction for multi‐shot multi‐slice MRI: Application to neonatal brain imaging
  • Cite Icon173
  • https://doi.org/10.1002/mrm.26796Copy DOI Icon

Three‐dimensional motion corrected sensitivity encoding reconstruction for multi‐shot multi‐slice MRI: Application to neonatal brain imaging

Show More
  • Abstract
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposeTo introduce a methodology for the reconstruction of multi‐shot, multi‐slice magnetic resonance imaging able to cope with both within‐plane and through‐plane rigid motion and to describe its application in structural brain imaging.Theory and MethodsThe method alternates between motion estimation and reconstruction using a common objective function for both. Estimates of three‐dimensional motion states for each shot and slice are gradually refined by improving on the fit of current reconstructions to the partial k‐space information from multiple coils. Overlapped slices and super‐resolution allow recovery of through‐plane motion and outlier rejection discards artifacted shots. The method is applied to T2 and T1 brain scans acquired in different views.ResultsThe procedure has greatly diminished artifacts in a database of 1883 neonatal image volumes, as assessed by image quality metrics and visual inspection. Examples showing the ability to correct for motion and robustness against damaged shots are provided. Combination of motion corrected reconstructions for different views has shown further artifact suppression and resolution recovery.ConclusionThe proposed method addresses the problem of rigid motion in multi‐shot multi‐slice anatomical brain scans. Tests on a large collection of potentially corrupted datasets have shown a remarkable image quality improvement. Magn Reson Med 79:1365–1376, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Loading PDF

Similar Papers
  • Research Article
  • Citations1

An inverse method for radio frequency phased array coil design in magnetic resonance imaging equipment

  • Aug 31, 2007
  • ANZIAM Journal
  • Peter T While +2
  • Research Article
  • Citations126

Revised guidance on acceptable limits of exposure during nuclear magnetic resonance clinical imaging.

  • Dec 01, 1983
  • The British journal of radiology
  • Research Article

Does Parametric fMRI Analysis with SPM Yield Valid Results? – An Empirical Study of 1484 Rest Datasets

  • Jan 01, 2012
  • Frontiers in Human Neuroscience
  • Josephson Camilla
  • PDF
  • Research Article
  • Citations45

International EANM-SNMMI-ISMRM consensus recommendation for PET/MRI in oncology

  • Aug 25, 2023
  • European journal of nuclear medicine and molecular imaging
  • Patrick Veit-Haibach +16
  • PDF
  • Research Article
  • Citations47

Cardiac perfusion imaging using hyperpolarized 13c urea using flow sensitizing gradients

  • May 20, 2015
  • Magnetic Resonance in Medicine
  • Angus Z Lau +3
  • Research Article
  • Citations17

Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

  • Jan 29, 2018
  • Magnetic Resonance in Medicine
  • Barbara Cervantes +8
  • PDF
  • Research Article
  • Citations42

A new paramagnetically shifted imaging probe for MRI

  • Feb 28, 2016
  • Magnetic Resonance in Medicine
  • P Kanthi Senanayake +9
  • PDF
  • Research Article
  • Citations14

Adiabatic excitation for 31P MR spectroscopy in the human heart at 7 T: A feasibility study

  • Dec 21, 2016
  • Magnetic Resonance in Medicine
  • Ladislav Valkovič +5
  • PDF
  • Research Article
  • Citations45

Dynamic 1H imaging of hyperpolarized [1‐13C]lactate in vivo using a reverse INEPT experiment

  • May 05, 2017
  • Magnetic Resonance in Medicine
  • Jiazheng Wang +5
  • Research Article
  • Citations8

Pseudo‐projection–driven, self‐gated cardiac cine imaging using cartesian golden step phase encoding

  • Oct 31, 2015
  • Magnetic Resonance in Medicine
  • Liheng Guo +2
  • Research Article
  • Citations112

PERISTALSIS, SEGMENTATION, AND THE MYENTERIC REFLEX

  • Apr 01, 1912
  • American Journal of Physiology-Legacy Content
  • W B Cannon
  • Research Article
  • Citations97

Magnetic Resonance in Medicine

  • Feb 01, 1991
  • Magnetic Resonance in Medicine
  • F Bloch +21
  • PDF
  • Research Article
  • Citations28

Phosphodiester content measured in human liver by in vivo 31P MR spectroscopy at 7 tesla

  • Feb 28, 2017
  • Magnetic Resonance in Medicine
  • Lucian A.B Purvis +8
  • PDF
  • Research Article
  • Citations20

Susceptibility‐induced distortion correction in hyperpolarized echo planar imaging

  • Jul 19, 2017
  • Magnetic Resonance in Medicine
  • Jack J Miller +2
  • PDF
  • Research Article
  • Citations38

Mapping of intracellular pH in the in vivo rodent heart using hyperpolarized [1‐13C]pyruvate

  • May 13, 2016
  • Magnetic Resonance in Medicine
  • Angus Z Lau +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.