• Home
  • Search
  • Three-dimensional PSF characterization of circle-plus-arc cone-beam computed tomography
  • Cite Icon3
  • https://doi.org/10.1117/12.595304Copy DOI Icon

Three-dimensional PSF characterization of circle-plus-arc cone-beam computed tomography

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Cone-beam CT (CBCT) realizes true three-dimensional (3D) imaging in terms of its direct volume reconstruction with isotropic resolution. However, the 3D imaging performance of a CBCT system is spatially variant (or non-uniform) over the support domain, which can be quantitatively characterized by 3D point spread function (PSF). The CBCT system PSF can be experimentally measured through the use of telfon ball and edge-spread technique. For a single circular scan orbit, its volume reconstruction fails to meet data sufficiency condition, consequently causing spatial shift variance. In the pursuit of meeting data sufficiency condition, we have proposed a circle-plus-arc CB scan scheme. The overall CBCT imaging process involves several factors, including x-ray source, cone-beam projection, and computational reconstruction; each factor can in principle be characterized by a convolution kernel or PSF. In this paper, we concentrate on the PSF characterization of circle-plus-arc algorithm. Based on the linearity of Radon transform and inverse Radon transform, we can partition the Radon domain. In particular, the circle-plus-arc scan scheme partitions the Radon domain into a donut-like region (associated with the circle scan) and funnel-like null region (provided by the arc scan). A modified FDK algorithm is responsible for donut region reconstruction, and a filtered-backprojection-styled inverse Radon transform is for the null region reconstruction. By adding them up, we obtain the complete volume reconstruction. Through the use of a bead array phantom (a 5×5×5 array), subject to cone-beam scan under different scan patterns and volume reconstruction, we calculated the local PSF blurs and the spatial variance. The result shows that, for our CBCT simulation with 28 degree cone angle, the circle scan produces a spatial variance of 9.3% and the circle-plus-arc scan reduces that to 1.8%.

Similar Papers
  • Conference Article
  • Citations1

Quantitative assessment of cone-beam CT system by 3D point-spread function

  • May 06, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Zikuan Chen +3
  • Research Article
  • Citations6

3D MTF estimation using sphere phantoms for cone-beam computed tomography systems.

  • Apr 18, 2020
  • Medical Physics
  • Changwoo Lee +2
  • Research Article
  • Citations24

Comparison of Cone Beam Computed Tomography and Multi Slice Computed Tomography Image Quality of Human Dried Mandible using 10 Anatomical Landmarks.

  • Jan 01, 2017
  • JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
  • Samira Saati
  • Research Article
  • Citations31

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

  • Mar 18, 2015
  • Medical Physics
  • Yidong Yang +5
  • Conference Article

Modified K-factor image decomposition for three-dimensional super resolution microscopy

  • Mar 09, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tali Ilovitsh +7
  • Research Article

Evaluation and implementation of an independent Kilovoltage X‐ray‐based imaging platform for carbon ion radiotherapy

  • Feb 01, 2026
  • Journal of Applied Clinical Medical Physics
  • Yixiao Guo +7
  • Research Article
  • Citations1

Depth-variant blind restoration with pupil-phase constraints for 3D confocal microscopy

  • Oct 14, 2013
  • Journal of Physics: Conference Series
  • Saima Ben Hadj +2
  • Conference Article
  • Citations6

Volumetric cone-beam CT system based on a 41x41 cm2flat-panel imager

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • David A Jaffray +1
  • PDF
  • Book Chapter
  • Citations8

Review on Cone Beam Computed Tomography (CBCT) Dose in Patients Undergoing Image Guided Radiotherapy (IGRT)

  • Nov 07, 2023
  • Panagiotis Iliopoulos +4
  • Research Article
  • Citations4

Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

  • Nov 03, 2018
  • Radiation and Environmental Biophysics
  • Mariana Baptista +6
  • Research Article
  • Citations71

Accuracy Assessment of Three-dimensional Surface Reconstructions of In vivo Teeth from Cone-beam Computed Tomography

  • Jun 20, 2016
  • Chinese Medical Journal
  • Yan-Hui Sang +5
  • Research Article
  • Citations31

A comparative study of the diagnostic accuracy of cone beam computed tomography and intraoral radiographic modalities for the detection of noncavitated caries

  • Jul 25, 2014
  • Clinical Oral Investigations
  • J Krzyżostaniak +3
  • Research Article
  • Citations1

WE‐EF‐207‐08: Improve Cone Beam CT Using a Synchronized Moving Grid, An Inter‐Projection Sensor Fusion and a Probability Total Variation Reconstruction

  • Jun 01, 2015
  • Medical Physics
  • H Zhang +5
  • Addendum
  • Citations2

Erratum: Using the ACR CT accreditation phantom for routine image quality assurance on both CT and CBCT imaging systems in a radiotherapy environment

  • Nov 01, 2014
  • Journal of Applied Clinical Medical Physics
  • Maritza A Hobson
  • Research Article
  • Citations1

A Compressed-Sensing Based Blind Deconvolution Method for Image Deblurring in Dental Cone-Beam Computed Tomography

  • Sep 20, 2018
  • Journal of Digital Imaging
  • K S Kim +12
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.