• Home
  • Search
  • Threshold Ranges of Multiphase Components from Natural Ice CT Images Based on Watershed Algorithm
  • Cite Icon2
  • https://doi.org/10.3390/w16223330Copy DOI Icon

Threshold Ranges of Multiphase Components from Natural Ice CT Images Based on Watershed Algorithm

  • Nov 19, 2024
  • Water
  • Shengbo Hu +3 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The multiphase components of natural ice contain gas, ice, unfrozen water, sediment and brine. X-ray computed tomography (CT) analysis of ice multiphase components has the advantage of high precision, non-destructiveness and visualization; however, it is limited by the segmentation thresholds. Due to the proximity of the CT value ranges of gas, ice, unfrozen water, sediment and brine within the samples, there is uncertainty in the artificial determination of the CT image segmentation thresholds, as well as unsuitability of the global threshold segmentation methods. In order to improve the accuracy of multi-threshold segmentation in CT images, a CT system was used to scan the Yellow River ice, the Wuliangsuhai lake ice and the Arctic sea ice. The threshold ranges of multiphase components within the ice were determined by watershed algorithm to construct a high-precision three-dimensional ice model. The results indicated that CT combined with watershed algorithm was an efficient and non-destructive method for obtaining microscopic information within ice, which accurately segmented the ice into multiphase components such as gas, ice, unfrozen water, sediment, and brine. The gas CT values of the Yellow River ice, the Wuliangsuhai lake ice and the Arctic sea ice ranged from −1024 Hu~−107 Hu, −1024 Hu~−103 Hu, and −1024 Hu~−160 Hu, respectively. The ice CT values of the Yellow River ice, the Wuliangsuhai lake ice and the Arctic sea ice ranged from −103 Hu~−50 Hu, −100 Hu~−38 Hu, −153 Hu~−51 Hu. The unfrozen water CT values of the Yellow River ice and the Wuliangsuhai lake ice ranged from −8 Hu~18 Hu, −8 Hu~13 Hu. The sediment CT values of the Yellow River ice and the Wuliangsuhai lake ice ranged from 20 Hu~3071 Hu, 20 Hu~3071 Hu, and the brine CT values of the Arctic sea ice ranged from −6 Hu~3071 Hu. The errors between the three-dimensional ice model divided by threshold ranges and measured sediment content were less than 0.003 g/cm3, which verified the high accuracy of the established microscopic model. It provided a scientific basis for ice engineering, ice remote sensing, and ice disaster prevention.

Similar Papers
  • Research Article
  • Citations8

Nanoparticles: Untying the Gordian Knot in Conventional Computed Tomography Imaging

  • May 11, 2021
  • CCS Chemistry
  • Zhen Sun +5
  • Research Article

Evaluation of Image Quality of Temporal Maximum Intensity Projection and Average Intensity Projection of Adaptive 4D-Spiral CT Scans: A Phantom Study.

  • Apr 07, 2025
  • Cureus
  • Hiroki Horinouchi +6
  • Research Article
  • Citations7

Dose-efficiency quantification of computed tomography systems using a model-observer.

  • May 14, 2023
  • Medical Physics
  • Maximilian Göppel +6
  • Research Article
  • Citations119

CT liver tumor segmentation hybrid approach using neutrosophic sets, fast fuzzy c-means and adaptive watershed algorithm.

  • Dec 14, 2018
  • Artificial Intelligence in Medicine
  • Ahmed M Anter +1
  • Research Article

Measurement accuracy of CT systems: The importance of calibration phantoms.

  • Jan 01, 2025
  • PloS one
  • Jan Scherberich +3
  • Research Article

CTにおける画像再構成フィルタがプラーク評価に及ぼす影響

  • Jan 01, 2014
  • Japanese Journal of Radiological Technology
  • Takuya Taniguchi +4
  • Research Article

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

  • Dec 01, 2018
  • Iranian Journal of Medical Physics
  • Zeinab Sattari +2
  • PDF
  • Research Article
  • Citations2

FUSION OF COMPUTED TOMOGRAPHY AND DIFFUSION-WEIGHTED MAGNETIC RESONANCE IMAGES FOR DETECTION OF PRIMARY, RESIDUAL AND RECURRENT CHOLESTEATOMA OF THE MIDDLE EAR

  • Jan 01, 2016
  • Almanac of Clinical Medicine
  • E A Stepanova +3
  • Research Article
  • Citations8

A Study of Three-dimensional Structures of Rocks and Minerals Using a High-resolution X-ray CT Method

  • Jan 01, 2000
  • Journal of Geography (Chigaku Zasshi)
  • Akira Tsuchiyama +2
  • Research Article

Computed tomography in diagnosis of posterior column fracture of tibial plateau

  • Nov 15, 2008
  • Chinese Journal of Orthopaedic Trauma
  • Fangqing Chen +2
  • Abstract
  • Citations1

COMPARISON OF 3D QUANTITATIVE OSTEOARTHRITIS IMAGING BIOMARKERS: A STUDY USING PAIRED CT AND MR IMAGES FROM THE IMI-APPROACH STUDY

  • Jan 01, 2022
  • Osteoarthritis Imaging
  • A.D Brett +2
  • Research Article
  • Citations1

SU-E-T-225: It Is Necessary to Contouring the Brainstem On MRI Images in Radiotherapy of Head and Neck Cancer

  • May 29, 2014
  • Medical Physics
  • G Gong +1
  • PDF
  • Research Article
  • Citations3

Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT.

  • Jun 10, 2022
  • Frontiers in Radiology
  • Xiaojing Zhao +6
  • Research Article
  • Citations1

Value of the Air Bronchogram Sign and Other Computed Tomography Findings in the Early Diagnosis of Lung Adenocarcinoma.

  • Mar 07, 2024
  • Journal of computer assisted tomography
  • Jia-Chang Liu +7
  • Research Article
  • Citations444

CT Dose Index and Patient Dose: They AreNotthe Same Thing

  • May 01, 2011
  • Radiology
  • Cynthia H Mccollough +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.