• Home
  • Search
  • Tissue characterization using mean gray value analysis in deep infiltrating endometriosis
  • Open Access IconOpen Access
  • Cite Icon15
  • https://doi.org/10.1002/uog.12292Copy DOI Icon

Tissue characterization using mean gray value analysis in deep infiltrating endometriosis

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To investigate differences in tissue characterization using three-dimensional sonographic mean gray value (MGV) between retrocervical and rectosigmoid deeply infiltrating endometriosis, and to assess intra- and interobserver concordance in MGV quantification. In this retrospective study, stored ultrasound volumes from 50 premenopausal women (mean age, 32 years) with 57 histologically confirmed nodules of deep endometriosis were retrieved from our database for analysis. A single experienced operator had acquired all volumes. For each nodule, the MGV was evaluated using virtual organ computer-aided analysis (VOCAL) software with semiautomated sphere-sampling (1 cm3) from the central part of the nodule. In these patients the MGV was also quantified from the myometrium of the fundal part of the uterus. In addition, two observers calculated the MGV in a subset of 24 volumes in order to quantify inter- and intraobserver agreement using intraclass correlation coefficients (ICC). Mean MGV was significantly higher in rectosigmoid nodules (n = 34) than in nodules with a retrocervical location (n = 23) (23.863 vs. 17.705; P < 0.001). MGV of the myometrium was significantly higher in comparison with that of nodules in both locations (P < 0.001 for both). Intra- and interobserver measurement reproducibility was excellent (ICC > 0.95). Retrocervical and rectosigmoid endometriotic nodules display significantly different MGVs. Measurement of MGV is highly reproducible and its clinical value in the diagnosis and assessment of distribution of deep endometriosis should be assessed in future studies.

Similar Papers
  • Research Article
  • Citations29

Assessment of cyst content using mean gray value for discriminating endometrioma from other unilocular cysts in premenopausal women

  • Jan 11, 2010
  • Ultrasound in Obstetrics &amp; Gynecology
  • J L Alcázar +3
  • Research Article
  • Citations10

The alteration in placental volume and placental mean grey value in growth-restricted pregnancies assessed by 3D ultrasound

  • Nov 19, 2014
  • Journal of Obstetrics and Gynaecology
  • B Artunc Ulkumen +4
  • Research Article
  • Citations10

Reference range of fetal cisterna magna volume by three-dimensional ultrasonography using the VOCAL method

  • Oct 22, 2013
  • The Journal of Maternal-Fetal & Neonatal Medicine
  • Edward Araujo Júnior +4
  • Research Article
  • Citations48

Three‐dimensional sonography of the placental and uterine spiral vasculature: Influence of maternal age and parity

  • May 02, 2008
  • Journal of Clinical Ultrasound
  • Ivica Zalud +1
  • Research Article
  • Citations2

Corpus Luteum Morphology and Vascularization Assessed by Transvaginal Two-dimensional and Three-dimensional Ultrasound

  • Jun 01, 2007
  • Donald School Journal of Ultrasound in Obstetrics and Gynecology
  • Jm Bajo +5
  • Research Article
  • Citations54

What is the incidence of holoprosencephaly?

  • Feb 01, 1984
  • Journal of Medical Genetics
  • E S Saunders +2
  • Research Article

Assessment Inter- and Intraobserver Agreement in Two Radiological Indexes in True Lateral X-Rays View for Syndesmotic Reduction in Ankle Fractures

  • Aug 01, 2016
  • Foot &amp; Ankle Orthopaedics
  • Jorge A Briceno +6
  • Research Article
  • Citations31

Reliability and Validity of In Vitro Volume Calculations by 3-Dimensional Ultrasonography Using the Multiplanar, Virtual Organ Computer-Aided Analysis (VOCAL), and Extended Imaging VOCAL Methods

  • May 01, 2010
  • Journal of Ultrasound in Medicine
  • Enoch Quinderé De Sá Barreto +6
  • Research Article
  • Citations2

Correlation analysis between decreased cerebral perfusion measured from arterial spin labeling and cerebrovascular events in patients with bilateral moyamoya angiography

  • Jun 22, 2021
  • Zhonghua yi xue za zhi
  • M X Wang +5
  • Research Article

P09.01: Comparison of inter- and intraobserver agreement between three different types of placental volume measurement techniques (XI VOCAL™, VOCAL™, and multiplanar)

  • Sep 01, 2009
  • Ultrasound in Obstetrics &amp; Gynecology
  • K Cheong +5
  • PDF
  • Research Article
  • Citations7

Diffusion-Weighted MRI in Patients with Testicular Tumors—Intra- and Interobserver Variability

  • Feb 02, 2022
  • Current Oncology
  • Malene Roland Vils Pedersen +4
  • Research Article
  • Citations4

Does the META score evaluating osteoporotic and metastatic vertebral fractures have enough agreement to be used by orthopaedic surgeons with different levels of training?

  • Jul 11, 2018
  • European Spine Journal
  • Julio Urrutia +6
  • Research Article

THU0533 A SINGLE MRI DIXON SEQUENCE TO ASSESS DISEASE ACTIVITY AND CARTILAGE IN EARLY RHEUMATOID HANDS: ONE SEQUENCE TO ASSESS THEM ALL?

  • Jun 01, 2020
  • Annals of the Rheumatic Diseases
  • T Kirchgesner +4
  • PDF
  • Research Article
  • Citations4

Concordance between US and MRI Two-Dimensional Measurement and Volumetric Segmentation in Fetal Ventriculomegaly

  • Mar 20, 2023
  • Diagnostics
  • George Hadjidekov +5
  • Research Article
  • Citations5

Orientation of Cone-Beam Computed Tomography Image: Pursuit of Perfect Orientation Plane in Three Dimensions—A Retrospective Cross-Sectional Study

  • Oct 01, 2019
  • Annals of the National Academy of Medical Sciences (India)
  • Rajiv Balachandran +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.