Transfer learning framework for low-dose CT reconstruction based on marginal distribution adaptation in multi-scale.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

With the increasing use of CT in clinical practice, limiting CT radiation exposure to reduce potential cancer risks has become one of the important directions of medical imaging research. As the dose decreases, the reconstructed CT image will be severely degraded by projection noise. As an important method of image processing, supervised deep learning has been widely used in the restoration of low-dose CT(LDCT) in recent years. However, the normal-dose CT (NDCT) corresponding to a specific LDCT (it is regareded as the label of the LDCT, which is necessary for supervised learning) are very difficult to obtain. So that the application of supervised learning methods in LDCT reconstruction is limited. It is necessary to construct a unsupervised deep learning framework for LDCT reconstruction that does not depend on paired LDCT-NDCTdatasets. We presented an unsupervised learning framework for the transferring from the identity mapping to the low-dose recontruction task, called Marginal Distribution Adaptation in Multi-scale (MDAM). For NDCTs as source domain data, MDAM is an identity map with two parts: firstly, it establishes a dimensionality reduction mapping, which can obtain the same feature distribution from NDCTs and LDCTs; and then NDCTs is retrieved by reconstructing the image overview and details from the low-dimensional features. For the purpose of the feature transfer between source domain and target domain (LDCTs), we introduce the multi-scale feature extraction in the MDAM, and then eliminate differences in probability distributions of these multi-scale features between NDCTs and LDCTs through wavelet decomposition and domain adaptationlearning. Image quality evaluation metrics and subjective quality scores show that, as an unsupervised method, the performance of the MDAM approaches or even surpasses some state-of-the-art supervised methods. Especially, MDAM has been favorably evaluated in terms of noise suppression, structural preservation, and lesiondetection. We demonstrated that, the MDAM framework can reconstruct corresponding NDCTs from LDCTs with high accuracy, and without relying on any labeles. Moreover, it is more suitable for clinical application compared with supervised learningmethods. This article is protected by copyright. All rights reserved.

Similar Papers
  • Research Article
  • Citations98

Artifact correction in low‐dose dental CT imaging using Wasserstein generative adversarial networks

  • Feb 14, 2019
  • Medical Physics
  • Zhanli Hu +8
  • Conference Article

Low-dose CT reconstruction with MRF prior predicted from patch samples of normal-dose CT database

  • Mar 09, 2018
  • Medical Imaging 2018: Physics of Medical Imaging
  • Junyan Rong +6
  • PDF
  • Research Article
  • Citations5

Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study

  • Aug 11, 2022
  • PLoS ONE
  • Sungjin Yoon +7
  • Conference Article
  • Citations13

Self Supervised Low Dose Computed Tomography Image Denoising Using Invertible Network Exploiting Inter Slice Congruence

  • Jan 01, 2023
  • Sutanu Bera +1
  • Conference Article
  • Citations1

A method to generate patient CT noise for deep learning network training

  • Apr 01, 2024
  • Minah Han +1
  • Conference Article
  • Citations4

Blind image quality evaluation metrics design for UAV photographic application

  • Jun 01, 2015
  • Haoting Liu +6
  • Research Article
  • Citations41

StatNet: Statistical Image Restoration for Low-Dose CT using Deep Learning

  • May 28, 2020
  • IEEE Journal of Selected Topics in Signal Processing
  • Kihwan Choi +2
  • Research Article
  • Citations10

Pure Vision Transformer (CT-ViT) with Noise2Neighbors Interpolation for Low-Dose CT Image Denoising.

  • Apr 15, 2024
  • Journal of imaging informatics in medicine
  • Luella Marcos +2
  • Research Article
  • Citations5

Enhancement based convolutional dictionary network with adaptive window for low-dose CT denoising.

  • Sep 02, 2023
  • Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
  • Yi Liu +5
  • Research Article
  • Citations30

Application of deep learning image reconstruction in low-dose chest CT scan.

  • Jan 31, 2022
  • The British Journal of Radiology
  • Huang Wang +4
  • Research Article
  • Citations324

Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery

  • Oct 01, 2005
  • IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
  • C.P Loizou +5
  • Conference Article
  • Citations3

Quality evaluation of ultrasound imaging using a MATLAB test-bench

  • Mar 29, 2013
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xin Zhao +4
  • Conference Article
  • Citations8

Modified non-local means filter for effective speckle reduction in ultrasound images

  • Apr 01, 2011
  • Banazier A Abrahim +2
  • Research Article

FADFNet: A fine-tunable and adaptive decomposition-fusion network for cross-dataset low-dose CT and low-dose PET image reconstruction.

  • Mar 01, 2026
  • Medical image analysis
  • Fangji Qian +9
  • Research Article
  • Citations61

HCformer: Hybrid CNN-Transformer for LDCT Image Denoising.

  • Jun 29, 2023
  • Journal of digital imaging
  • Jinli Yuan +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.