• Home
  • Search
  • Two harmonic analysis of short circuit current in wind farm
  • Cite Icon1
  • https://doi.org/10.1049/joe.2017.0479Copy DOI Icon

Two harmonic analysis of short circuit current in wind farm

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

With the increase of capacity and the improvement of economy, doubly‐fed induction generator (DFIG) is gradually becoming the most widely used wind power generator in the world. DFIG has different characteristics of transient operation from the synchronous generator and its short‐circuit current is affected by the converter control mode, thus when there is a voltage sags occurs, the short‐circuit current of the wind farm may contain a certain amount of two harmonic. Power transformer is one of the most important power equipment in power system and the normal or not of transformer protection determines the safe and stable operation of power system. At present, the main protection of transformer is longitudinal differential protection. In order to correctly identify the inrush current, it is usually equipped with two harmonic braking measures to ensure the reliable operation of differential protection. Therefore, when the transformer failure occurs in wind farm, the protection may refuse to operate due to the reason that the short‐circuit current contains a certain amount of two harmonic. Focused on the large‐scale application of DFIG and the lack of the short‐circuit current harmonic characteristics analysis, this work is devoted to the study of two harmonic characteristics and their influence on transformer protection when the grid voltage occurs in a non‐depth drop. Through the analysis of the short‐circuit current, harmonic components under different control modes of converter research the characteristics and production mechanism of the two harmonic currents of the doubly‐fed wind power generator. This also lays a solid foundation for the improvement of transformer protection. Finally, the correctness of the analysis is verified by the experiments of short‐circuit and time‐domain simulation.

Similar Papers
  • PDF
  • Research Article
  • Citations9

MPC Based Coordinated Active and Reactive Power Control Strategy of DFIG Wind Farm with Distributed ESSs

  • Jun 29, 2021
  • Energies
  • Hesong Cui +5
  • Research Article
  • Citations30

Collective Impact of Multiple Doubly Fed Induction Generators With Similar Dynamics on the Oscillation Stability of a Grid-Connected Wind Farm

  • Oct 01, 2021
  • IEEE Transactions on Power Delivery
  • Wenjuan Du +4
  • Conference Article
  • Citations6

High-Frequency Resonance of DFIG-Based Wind Generation under Weak Power Network

  • Nov 01, 2018
  • Lin Zhu +2
  • Research Article
  • Citations7

Model development and small‐signal stability analysis of DFIG with stator winding inter‐turn fault

  • Jan 27, 2017
  • IET Renewable Power Generation
  • Liling Sun +3
  • Conference Article
  • Citations4

Operational restrictions with maximum power extraction of DFIG connected wind farms

  • Nov 01, 2008
  • A P Tennakoon +4
  • Research Article
  • Citations18

Modeling and analysis of reactive power in grid-connected onshore and offshore DFIG-based wind farms

  • Dec 06, 2012
  • Wind Energy
  • M El-Shimy
  • Conference Article
  • Citations5

Performance improvement of DFIG-based wind farm using multilevel cascaded H-bridge converter under unbalanced grid voltage conditions

  • May 01, 2014
  • Yunes Shokri +3
  • Research Article
  • Citations3

Augmentation of Wind Farms Ride Through by DFIG-based Variable Speed Wind Generators

  • Mar 01, 2012
  • Journal of international Conference on Electrical Machines and Systems
  • K.E Okedu +3
  • Research Article
  • Citations26

Economic feasibility of a wind-battery system in the electricity market with the fluctuation penalty

  • Jul 01, 2020
  • Journal of Cleaner Production
  • Xiao Xu +7
  • Conference Article

Var Coordinated Control of DFIG Impact on Small Signal Stability of Power System

  • Apr 06, 2012
  • Lei Wang +1
  • Conference Article
  • Citations4

An active PID-based inertial control of a doubly-fed induction generator

  • Jun 01, 2016
  • Thelfa Ahmad +2
  • Research Article

Research on Voltage Stability in Grid-Connected Large Wind Farms

  • Oct 01, 2011
  • Advanced Materials Research
  • An Lin
  • Conference Article
  • Citations5

Electromagnetic and temperature field analyses of winding short-circuits in DFIGs

  • Aug 01, 2013
  • Zheng Liu +5
  • PDF
  • Research Article
  • Citations3

Optimization of Fuzzy Control Parameters for Wind Farms and Battery Energy Storage Systems Based on an Enhanced Artificial Bee Colony Algorithm under Multi-Source Sensor Data.

  • Aug 07, 2024
  • Sensors (Basel, Switzerland)
  • Zejian Liu +5
  • Conference Article
  • Citations2

Impacts of DFIG-Based Wind Power System on Migration Mechanism of Oscillation Center

  • May 01, 2019
  • Fei Tang +5
Cactus Communications logo