• Home
  • Search
  • Ultra-precise distance measurement for nanometrology
  • Cite Icon1
  • https://doi.org/10.1117/12.545924Copy DOI Icon

Ultra-precise distance measurement for nanometrology

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

We present experimental results achieved by a method of direct conversion of the relative changes of the measurement optical path of Michelson interferometer to relative changes of the resonant optical-frequency of Fabry-Perot (F.-P.) resonator. We developed the method as a testing process for verification of scale-linearity of Michelson interferometer with total resolution 0,3 nm. The method consists of a mechanical coupled shift of the corner cube mirror of the interferometer measurement arm with one of the mirrors of F.-P. resonator. A piezoelectric transducer (PZT) with approximately 10 microns elongation drives that mechanical shift. An external tunable laser source at 633 nm wavelength provides identification of one of the resonant optical frequency of F.-P. resonator by the frequency locking mechanism with synchronous detection technique in the servo loop feedback. Because definition of the meter unit is based on iodine stabilized He-Ne laser, then the optical frequency of the locked tunable laser is frequency compared with HeNeI2 laser by the heterodyne optical mixing. A fast high-resolution counter counts the resultant radio-frequency signal as a product of the optical mixing. Measured frequency values and values of interference phase acquired by the interferometer are simultaneously sampled step by step for each elongation position of PZT element. The experimental data achieved by F.-P. resonator shows uncertainty of the relative distance change better than 0,01 nm. We verified the scale-linearity of Michelson interferometer to ±1,0 nm limit.

Similar Papers
  • Conference Article

Research of optical coherence tomography microscope based on CCD detector

  • Dec 03, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Hua Zhang +2
  • Conference Article

Attosecond measurement of fiber-optic chromatic dispersion by white-light interferometry

  • Jan 01, 1995
  • Valeria Gusmeroli +1
  • Conference Article
  • Citations3

<title>Multi-analyte array microdiffraction interferometry</title>

  • Jun 19, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Manoj M Varma +3
  • Conference Article
  • Citations1

Sensitivity increase in digital holographic interferometry

  • Apr 25, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nazif Demoli +5
  • Conference Article
  • Citations2

High sensitivity laser interferometry for detection of boundary-layer transition

  • Jun 25, 1984
  • D Modarress +3
  • Research Article
  • Citations3

Sensitivity and nonlinearity of optical path difference measurements using triple-exposure heterodyne holographic interferometry

  • Sep 15, 1986
  • Applied Optics
  • James W Wagner
  • Research Article

Quantifying Influence of Beam Drift on Linear Retardance Measurement in Dual-Rotating Retarder Mueller Matrix Polarimetry

  • Aug 28, 2025
  • Photonics
  • Kaisha Deng +6
  • Research Article
  • Citations1

Application of the correlation method to analyze deformations in transparent materials

  • Sep 01, 2012
  • Bulletin of the Lebedev Physics Institute
  • A V Kraiskii +3
  • Research Article

Effects of seat height on muscular pattern and interlimb coordination in cycling

  • Nov 17, 2016
  • Journal Of Science & Cycling
  • L Dedieu
  • Research Article

Tunable Solid-state Laser. Expansion of Tunable Range of Pulsed Ti: sapphire Lasers by Nonlinear Optical Techniques.

  • Jan 01, 1995
  • The Review of Laser Engineering
  • Mitsuo Maeda +2
  • Conference Article
  • Citations1

A field calibration method to eliminate the error caused by relative tilt on roll angle measurement

  • Nov 24, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jingya Qi +4
  • Research Article
  • Citations26

Multi-wavelength generation by self-seeded four-wave mixing

  • Mar 04, 2013
  • Optics Express
  • N A Cholan +4
  • Research Article

Fabrication of Photolithography Micro-grating pattern for DNA Optical Biosensors

  • Jan 01, 2010
  • Naphat Chathirat
  • Research Article
  • Citations12

A carbon monoxide detection device based on mid-infrared absorption spectroscopy at 4.6 μm

  • Mar 03, 2015
  • Applied Physics B
  • Guo-Lin Li +5
  • Research Article
  • Citations2

Mid-infrared carbon monoxide detection system using differential absorption spectroscopy technique

  • Nov 01, 2015
  • Optoelectronics Letters
  • Ming Dong +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.