• https://doi.org/10.6100/ir732489Copy DOI Icon

Ultracold ion beam source

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

UltraCold Ion Beam Source. Focused ion beam (FIB) machines are largely used in the semiconductor industry mainly for imaging, milling and deposition of material, at the nanometer scale. To keep up with the trend of making smaller and smaller components, FIBs need to be continuously improved. A FIB is mainly made of an ion source and a focusing column. In this thesis, two concepts of ion sources are presented, modeled and discussed. The ultra-cold ion source (UCIS) is based on creating very cold ion beams (T <1 mK) by near-threshold photo-ionization of a laser-cooled and trapped atomic gas. In our experiment, 85Rb atoms are confined in a magneto optical trap built directly inside an accelerator structure. A spherical portion of the atom cloud is ionized with a 2-step ionization process and the bunched ions are accelerated by either a DC or a pulsed electric field. The liquid-metal ion source (LMIS) is the current state-of-art for focused ion beam technology, having a reduced brightness of 106 A/m2 sr eV. The reduced brightness characterizes the source and is proportional to the ion current and inversely proportional to the beam emittance (closely related with the source temperature). A high brightness is of importance as much as a low energy spread of the ion beam, since the latter is related with the focus ability of the beam. We have already shown that the UCIS can provide much lower energy spread (20 meV) than LMIS (˜ 4.5 eV), see Reijnders et al. (PRL, 2009), but not yet in combination with a high brightness as well. The energy spread is the limiting factor for the final achievable spot size in a FIB based on a LMIS. Chapter 3 and 4 present measurements of the source temperature and of the extracted current to complete the characterization of the UCIS. The ultra low temperature of the source permits collimated bunches to be created at low kinetic energy (down to few eV), which allows using time-dependent fields for accelerating and focusing. With this lens, a transversal ion temperature of (3±2) mK has been measured, as shown in chapter 3. This temperature is an upper limit since it is ten times higher than the expected value. The novel technique of focusing with time-dependent electric field is successfully applied to an ultra cold ion beam. In chapter 4, a dynamic model of the source describing its properties under pulsed operation has been developed and experiments validated it. A maximum average ion current of (13 ± 1) pA has been extracted from the UCIS and this is enough for imaging (1-100 pA are used). Those results correspond to a source reduced brightness of (8 ± 1) × 104 A/m2 sr eV with 0.9 eV energy spread. This result is 12.5 times lower than the brightness of a LMIS. An interesting pushing effect, due to the laser used to excite the atoms in the cloud, is described as well. Particle tracking simulations show that disorder induced heating has an important effect on the brightness, lowering its value by 1-2 orders of magnitude depending on the extracted current. Calculations and simulations of a different ion source, the atomic beam laser-cooled ion source (ABLIS), are presented in chapter 6. The follow-up project is based on a similar idea as an UCIS but aims for production of ion beams from a much higher initial atomic flux. The atoms originate from a Knudsen cell and, after being cooled and compressed transversally with laser cooling and trapping techniques, are photo-ionized and accelerated. The source size is reduced as well with respect to the UCIS. Realistic particle tracking simulations with 87Rb show that disorder induced heating is still very important, but in certain conditions, the so-called pencil-beam regime is reached and the disorder-induced heating does not deteriorate the brightness anymore. Depending on the extracted current, it is possible to reach a reduced brightness of 2 × 107 A/m2 sr eV with an ion current of 22 pA (corresponding to a final aperture diameter df = 1.6 µm) and an energy spread of 0.7 eV can be achieved. This source is likely capable of provide a high brightness and a low energy spread at the same time. The calculations are done assuming a purified 87Rb source. Eventually, it is possible to reach very high current (1 nA), making the ABLIS ideal also for milling applications with FIBs.

Similar Papers
  • Research Article
  • Citations12

Direct Magneto-Optical Compression of an Effusive Atomic Beam for Application in a High-Resolution Focused Ion Beam

  • May 22, 2017
  • Physical Review Applied
  • G Ten Haaf +6
  • Research Article
  • Citations176

High brightness inductively coupled plasma source for high current focused ion beam applications

  • Nov 01, 2006
  • Journal of Vacuum Science &amp; Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
  • N S Smith +7
  • Research Article
  • Citations6

Polyatomic ions from a high current ion implanter driven by a liquid metal ion source.

  • Dec 01, 2017
  • Review of Scientific Instruments
  • W Pilz +4
  • Single Report

Production of low axial energy spread ion beams with multicusp sources

  • May 01, 1998
  • Yung -Hee Y Lee
  • Research Article
  • Citations28

Focused ion beam machining and deposition for nanofabrication

  • May 01, 1996
  • Vacuum
  • St Davies +1
  • Research Article

Energy spread of boron palladium liquid metal ion source and characterization with focused ion beam system

  • Jun 01, 1995
  • Review of Scientific Instruments
  • Ronnie Higuchi-Rusli
  • Research Article
  • Citations18

Review of high brightness ion sources for microlithography (invited)

  • Mar 01, 1996
  • Review of Scientific Instruments
  • V G Dudnikov
  • Book Chapter
  • Citations1

Chapter 2 Focused Ion Beam Implantation TechnologyS

  • Jan 01, 1990
  • Semiconductors and Semimetals
  • Hisao Hashimoto
  • Research Article
  • Citations1

A compact radio-frequency ion source for high brightness and low energy spread negative oxygen ion beam production.

  • Sep 01, 2023
  • Review of Scientific Instruments
  • Y Zhou +8
  • Research Article
  • Citations14

Considerations on accelerator systems requirements and limitations for μ-probe applications

  • Mar 23, 2005
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
  • J Visser +3
  • Conference Article
  • Citations10

Capillary vs. externally wetted ionic liquid ion sources

  • Jul 09, 2006
  • Sergio Castro +4
  • Research Article
  • Citations11

High-field ion sources and applicationsa)

  • May 01, 1992
  • Review of Scientific Instruments
  • R Mühle
  • Conference Article
  • Citations1

Surface and material analytics based on Dresden-EBIS platform technology

  • Jan 01, 2015
  • AIP conference proceedings
  • M Schmidt +4
  • Research Article
  • Citations22

Design of a low-aberration lens for focused ion beams

  • May 01, 1988
  • Journal of Vacuum Science &amp; Technology B: Microelectronics Processing and Phenomena
  • Takashi Tsumagari
  • Research Article
  • Citations13

High resolution and high density ion beam lithography employing HSQ resist

  • May 29, 2012
  • Microelectronic Engineering
  • L Bruchhaus +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.