- Research Article
- 10.1088/1742-6596/910/1/012034
Feature Extraction Method based on AIC-Fisher Application in Ultrasonic Testing
- Oct 01, 2017
- Journal of Physics: Conference Series
- Banteng Liu + 2 more +2
In ultrasonic testing, the feature extraction of ultrasonic signal is equivalent to defect feature extraction. How to extract the effective signal features is the key to the defect identification. Traditional of ultrasonic signal features (echo time and peak value) insufficient to reflected defects characteristics. Commonly use features extraction and has supervision of discriminant method to optimization signal features. Fisher linear discriminant is to reduce the high-dimensional features to one-dimensional space, and to calculate the feature projection matrix according to the sample point distribution in one dimensional space. But the sample point distribution misclassification rate of one-dimensional feature is not optimal. So paper proposed a feature extraction method based on AIC-Fisher. The dimension of dimensionality reduction and dimensionality reduction are determined by Fisher criterion, sample point distribution error rate and AIC criterion. Then, the optimal feature set is used to quantify the defect depth. Finally, the experimental results show that this method can obtain the effective features, and has a high accuracy in the identification of defect depth.
Read more