• Home
  • Search
  • Using pressure-driven flow systems to evaluate laser speckle contrast imaging
  • Cite Icon8
  • https://doi.org/10.1117/1.jbo.28.3.036003Copy DOI Icon

Using pressure-driven flow systems to evaluate laser speckle contrast imaging

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

.SignificanceMicrofluidic flow phantom studies are commonly used for characterizing the performance of laser speckle contrast imaging (LSCI) instruments. The selection of the flow control system is critical for the reliable generation of flow during testing. The majority of recent LSCI studies using microfluidics used syringe pumps for flow control.AimWe quantified the uncertainty in flow generation for a syringe pump and a pressure-regulated flow system. We then assessed the performance of both LSCI and multi-exposure speckle imaging (MESI) using the pressure-regulated flow system across a range of flow speeds.ApproachThe syringe pump and pressure-regulated flow systems were evaluated during stepped flow profile experiments in a microfluidic device using an inline flow sensor. The uncertainty associated with each flow system was calculated and used to determine the reliability for instrument testing. The pressure-regulated flow system was then used to characterize the relative performance of LSCI and MESI during stepped flow profile experiments while using the inline flow sensor as reference.ResultsThe pressure-regulated flow system produced much more stable and reproducible flow outputs compared to the syringe pump. The expanded uncertainty for the syringe pump was 8 to higher than that of the pressure-regulated flow system across the tested flow speeds. Using the pressure-regulated flow system, MESI outperformed single-exposure LSCI at all flow speeds and closely mirrored the flow sensor measurements, with average errors of and , respectively.ConclusionsPressure-regulated flow systems should be used instead of syringe pumps when assessing the performance of flow measurement techniques with microfluidic studies. MESI offers more accurate relative flow measurements than traditional LSCI across a wide range of flow speeds.

Loading PDF

Similar Papers
  • Research Article
  • Citations90

Chronic Imaging of Cortical Blood Flow using Multi-Exposure Speckle Imaging

  • Apr 10, 2013
  • Journal of Cerebral Blood Flow & Metabolism
  • Syed Mohammad Shams Kazmi +4
  • Conference Article
  • Citations2

Development of a multi-exposure speckle imaging for mice brain imaging

  • Feb 08, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Haleh Soleimanzad +2
  • Research Article
  • Citations4

Quasi-analytic solution for real-time multi-exposure speckle imaging of tissue perfusion.

  • Jul 10, 2023
  • Biomedical optics express
  • Daniel A Rivera +1
  • PDF
  • Research Article
  • Citations11

Microfluidic-based laser speckle contrast imaging of erythrocyte flow and magnetic nanoparticle retention in blood

  • Jan 01, 2019
  • AIP Advances
  • Yamin Yang +3
  • Research Article
  • Citations27

Robust quantitative single-exposure laser speckle imaging with true flow speckle contrast in the temporal and spatial domains.

  • Jul 17, 2019
  • Biomedical Optics Express
  • Chenge Wang +6
  • Research Article

Individuals with early onset (premature) coronary artery disease display impaired systemic microvascular endothelial function: studies using laser speckle contrast imaging

  • Aug 02, 2013
  • European Heart Journal
  • E Tibirica +4
  • Research Article
  • Citations6

Local scattering property scales flow speed estimation in laser speckle contrast imaging

  • Jun 12, 2015
  • Laser Physics Letters
  • Peng Miao +6
  • Research Article
  • Citations14

Reducing misfocus-related motion artefacts in laser speckle contrast imaging.

  • Dec 24, 2014
  • Biomedical optics express
  • Dene Ringuette +3
  • Conference Article

Comparison of cerebral microcirculation of alloxan diabetes and healthy mice using laser speckle contrast imaging

  • Mar 19, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Polina A Timoshina +6
  • Research Article
  • Citations14

Water-head pumps provide precise and fast microfluidic pumping and switching versus syringe pumps

  • Jan 01, 2016
  • Microfluidics and Nanofluidics
  • Changik Kim +3
  • Research Article
  • Citations23

Comparison of Seven Methods of Preparing and Administering Small-Volume Injections

  • Sep 01, 1988
  • American Journal of Health-System Pharmacy
  • Christine Foltyn Smith +1
  • Research Article
  • Citations9

Development of a Mechatronic Syringe Pump to Control Fluid Flow in a Microfluidic Device Based on Polyimide Film

  • Aug 01, 2017
  • IOP Conference Series: Materials Science and Engineering
  • Kian Sek Tee +3
  • Research Article
  • Citations8

Arterial fast bolus flush systems used routinely in neonates and infants cause retrograde embolization of flush solution into the central arterial and cerebral circulation.

  • Apr 01, 2003
  • Canadian Journal of Anesthesia/Journal canadien d'anesthésie
  • Markus Weiss +5
  • Research Article
  • Citations15

Depth resolution in multifocus laser speckle contrast imaging.

  • Oct 01, 2021
  • Optics Letters
  • Shuqi Zheng +4
  • PDF
  • Research Article

Depth of Field Extension in Laser Speckle Contrast Imaging

  • Jan 01, 2020
  • IEEE Access
  • Xiaohui Ma +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.