• Home
  • Search
  • Variability of pulse width in transcranial magnetic stimulation
  • Cite Icon5
  • https://doi.org/10.1088/1741-2552/ad367aCopy DOI Icon

Variability of pulse width in transcranial magnetic stimulation

Show More
  • Abstract
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Objective. There is a high variability in the physiological effects of transcranial magnetic brain stimulation, resulting in limited generalizability of measurements. The cause of the variability is assumed to be primarily based on differences in brain function and structure of the stimulated individuals, while the variability of the physical properties of the magnetic stimulus has so far been largely neglected. Thus, this study is dedicated to the systematic investigation of variability in the pulse width of different TMS pulse sources at different stimulation intensities. Approach. The pulse widths of seven MagVenture® pulse sources were measured at the output of 10%–100% stimulation intensity in 10% increments via Near Field Probe and oscilloscope. The same C-B60 coil was used to deliver biphasic pulses. Pulse widths were compared between pulse sources and stimulation intensities. Main results. The mean sample pulse width was 288.11 ± 0.37 µs, which deviates from the value of 280 µs specified by the manufacturer. The pulse sources and stimulation intensities differ in their average pulse width (p’s < .001). However, the coefficient of variation within the groups (pulse source; stimulation intensity) were moderately low (CV = 0.13%–0.67%). Significance. The technical parameter of pulse width shows deviations from the proposed manufacturer value. According to our data, within a pulse source of the same manufacturer, the pulse width variability is minimal, but varies between pulse sources of the same and other pulse source models. Whether the observed variability in pulse width has potential physiological relevance was tested in a pilot experiment on a single healthy subject, showing no significant difference in motor evoked potential amplitude and significant difference in latencies. Future research should systematically investigate the physiological effects of different pulse lengths. Furthermore, potential hardware ageing effects and pulse amplitude should be investigated.

Loading PDF

Similar Papers
  • Research Article
  • Citations17

Brief vs. ultrabrief pulse ECT: focus on seizure quality.

  • Jul 18, 2018
  • European Archives of Psychiatry and Clinical Neuroscience
  • Isabelle Brunner +1
  • Research Article
  • Citations30

Cortical fNIRS Responses Can Be Better Explained by Loudness Percept than Sound Intensity.

  • Sep 01, 2020
  • Ear &amp; Hearing
  • Stefan Weder +5
  • Research Article
  • Citations8

Normal visual evoked potentials in preschool children born small for gestational age

  • Mar 11, 2011
  • Acta Paediatrica
  • Josefin Nilsson +3
  • Research Article

Design of picosecond pulse source based on MOSFET and step recovery diode

  • Apr 15, 2017
  • High Power Laser and Particle Beams
  • Zhang Yansong +3
  • Research Article
  • Citations3

Normalization of Bone Conduction Auditory Brainstem Evoked Responses in Normal Hearing Individuals.

  • Sep 03, 2019
  • The Journal of International Advanced Otology
  • Tuba Türkman +6
  • Research Article
  • Citations38

Sex Difference in Susceptibility to Epileptic Seizures in Rats: Importance of Estrous Cycle

  • Jan 01, 2001
  • International Journal of Neuroscience
  • Meliha Tan +1
  • Research Article
  • Citations7

Comparison of the brainstem auditory evoked responses during sevoflurane or alfaxalone anaesthesia in adult cats

  • Mar 02, 2017
  • Veterinary Anaesthesia and Analgesia
  • Carlos Ros +2
  • Research Article
  • Citations1052

Iconic memory and visible persistence.

  • May 01, 1980
  • Perception &amp; Psychophysics
  • Max Coltheart
  • Research Article
  • Citations1

Facilitation of motor evoked potentials in the anterior tibial muscle by repetitive subthreshold electrical stimulation.

  • Jul 01, 2001
  • Medical & biological engineering & computing
  • S Nebuya +4
  • Research Article

Effects of the Mongolian Medicine Ming Mu-11 on Retinal Functions in Stage I Diabetic Retinopathy

  • Jun 25, 2019
  • Chinese Journal of Optometry & Ophthalmology
  • Zhanjun Lu +5
  • Conference Article
  • Citations4

Advances in high-power harmonic generation: Q-switched lasers with electronically adjustable pulse width

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Loren A Eyres +4
  • Conference Article
  • Citations13

Respiratory Rate Detection Using a Camera as Contactless Sensor

  • Sep 14, 2017
  • Computing in cardiology
  • Luca Iozzia +5
  • Research Article
  • Citations18

Consecutive transcranial magnetic stimulation twitches reduce flow limitation during sleep in apnoeic patients

  • Jun 04, 2013
  • Experimental Physiology
  • César Augusto Melo‐Silva +3
  • Research Article
  • Citations47

Characterization of a high-intensity bipolar-mode pulsed ion source for surface modification of materials

  • Mar 27, 2002
  • Review of Scientific Instruments
  • X P Zhu +2
  • Research Article
  • Citations15

A fast (30μs) pulsed supersonic nozzle beam source: application to the photodissociation of CS2at 193 nm

  • Oct 01, 1986
  • Journal of Physics E: Scientific Instruments
  • M D Barry +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.