• Home
  • Search
  • Vascular contributions to pattern analysis: Comparing gradient and spin echo fMRI at 3T
  • Cite Icon13
  • https://doi.org/10.1016/j.neuroimage.2010.03.061Copy DOI Icon

Vascular contributions to pattern analysis: Comparing gradient and spin echo fMRI at 3T

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Multivariate pattern analysis is often assumed to rely on signals that directly reflect differences in the distribution of particular neural populations. The source of the signal used in these analyses remains unclear however, and an alternative model suggests that signal from larger draining veins may play a significant role. The current study was designed to investigate the vascular contribution to pattern analyses at 3T by comparing the results obtained from gradient and spin echo data. Classification analyses were carried out comparing line orientations in V1, tone frequencies in A1, and responses from different fingers in M1. In all cases, classification accuracy in the spin echo data was not significantly different from chance. In contrast, classification accuracies in the gradient echo data were significantly above chance, and significantly higher than the accuracies observed for the spin echo data. These results suggest that at the field strength and spatial resolution used for the majority of fMRI studies, a considerable proportion of the signal used by pattern analysis originates in the vasculature.

Similar Papers
  • PDF
  • Research Article
  • Citations18

Magnetic Resonance Q Mapping Reveals a Decrease in Microvessel Density in the arcAβ Mouse Model of Cerebral Amyloidosis

  • Jan 19, 2016
  • Frontiers in Aging Neuroscience
  • Giovanna D Ielacqua +5
  • Abstract

4896113 Use of repeated gradient echoes for noise reduction and improved NMR imaging

  • Jan 01, 1991
  • Magnetic Resonance Imaging
  • Norbert J Pelc
  • Research Article
  • Citations7

Improvement in signal-to-noise ratio and reduction of chemical shift and motion-induced artifacts by summation of gradient and spin echo data acquisition.

  • Nov 01, 1989
  • Journal of computer assisted tomography
  • Simon Vinitski +3
  • Conference Article

Improved Microstructure-Informed Myelin Mapping (iMIMM) for Myelin Mapping solely from Gradient-Echo Data

  • Sep 16, 2025
  • Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
  • Mert Şişman +4
  • Research Article
  • Citations10

Magnetic resonance imaging (MRI) artefacts in hip prostheses: a comparison of different prosthetic compositions

  • Dec 03, 2013
  • La radiologia medica
  • Elisabetta Panfili +5
  • PDF
  • Research Article
  • Citations19

Comparison of Dixon Sequences for Estimation of Percent Breast Fibroglandular Tissue.

  • Mar 24, 2016
  • PLOS ONE
  • Araminta E W Ledger +8
  • Research Article
  • Citations37

Multi-compartment relaxometry and diffusion informed myelin water imaging – Promises and challenges of new gradient echo myelin water imaging methods

  • Jul 11, 2020
  • NeuroImage
  • Kwok-Shing Chan +1
  • PDF
  • Research Article
  • Citations58

Functional Magnetic Resonance Imaging in Conscious Animals: A New Tool in Behavioural Neuroscience Research

  • Mar 28, 2006
  • Journal of Neuroendocrinology
  • Cf Ferris +8
  • PDF
  • Research Article
  • Citations64

BOLD Specificity and Dynamics Evaluated in Humans at 7 T: Comparing Gradient-Echo and Spin-Echo Hemodynamic Responses

  • Jan 15, 2013
  • PLoS ONE
  • Jeroen C W Siero +5
  • Research Article
  • Citations12

Establishing the overlap of IONP quantification with echo and echoless MR relaxation mapping.

  • Jun 26, 2017
  • Magnetic Resonance in Medicine
  • Hattie L Ring +5
  • Research Article

Functional Neuroimaging of a Complex Motor Task

  • Nov 01, 1998
  • Rivista di Neuroradiologia
  • V.P Mathews +5
  • Research Article
  • Citations25

Influence of pulse sequence parameters at 1.5 T and 3.0 T on MRI artefacts produced by metal-ceramic restorations.

  • Jun 18, 2015
  • Dentomaxillofacial Radiology
  • A R G Cortes +4
  • Research Article
  • Citations46

Multivariate Pattern Analysis of Functional Magnetic Resonance Imaging Data Reveals Deficits in Distributed Representations in Schizophrenia

  • Sep 25, 2008
  • Biological psychiatry
  • Jong H Yoon +5
  • PDF
  • Research Article
  • Citations14

Region-specific susceptibility change in cognitively impaired patients with diabetes mellitus.

  • Oct 11, 2018
  • PLOS ONE
  • Mina Park +5
  • PDF
  • Research Article
  • Citations49

Linear Discriminant Analysis Achieves High Classification Accuracy for the BOLD fMRI Response to Naturalistic Movie Stimuli

  • Mar 31, 2016
  • Frontiers in Human Neuroscience
  • Hendrik Mandelkow +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.