Due to the complexity of radiotherapy techniques, rigorous Patient-Specific Quality Assurance (PSQA) is crucial to ensure the accuracy of treatment plans. This study aims to evaluate the performance of the Treatment Planning System (TPS) by comparing its dose distribution calculations with those obtained from the PRIMO Monte Carlo simulation. Treatment plans for 3D-CRT, IMRT, and VMAT were generated for a Rando breast phantom using the TPS. Subsequently, the dose distributions from the TPS were compared with those obtained from the PRIMO Monte Carlo simulation. Key metrics, including Homogeneity Index (HI) and Conformity Index (CI), were calculated to assess the quality of dose distribution. Furthermore, the dose constraints on OARs were evaluated to assess the impact on surrounding healthy tissues. To further validate the TPS, dose distributions from the linac log file (Dynalog) for VMAT were reconstructed within the PRIMO environment. These reconstructed distributions were then compared with the dose distributions calculated directly by the TPS. Gamma index analysis was employed to evaluate the agreement between these two sets of data. The comparison between TPS and Monte Carlo simulations revealed that 3D-CRT plans exhibited smaller deviations in HI and CI compared to IMRT and VMAT plans. However, a significant improvement in HI and CI values was observed in both IMRT planning simulations and Dynalog VMAT file simulations, indicating enhanced plan quality. The dose received by OARs in all treatment plans remained within the acceptable dose thresholds, demonstrating effective sparing of surrounding healthy tissues. For the PSQA procedure, the 3D-CRT technique is still the safest due to its lower level of complexity compared to IMRT and VMAT. More complex treatments should consider the robustness of treatment transfer information from TPS to linac to avoid dosimetry errors.

Similar Papers
  • Research Article

Comparison of Radiation Dose Achievements in Breast Cancer Patients for Variations of Irradiation Direction in Intensity Modulated Radiation Therapy (IMRT)

  • May 26, 2025
  • International Journal of Scientific Research in Science and Technology
  • Elisabet Turnip +3
  • Abstract

Abstract ID: 200 Evaluation of key parameters for non-small cell lung cancer treatments using Geant4 as benchmark dose calculation algorithm

  • Oct 01, 2017
  • Physica Medica
  • Álvaro Perales +3
  • Research Article

Assessment of two different dose distribution algorithms (Clarkson and Superposition) in PCRT3D treatment planning system for Esophagus Cancer by using 3DCRT technique

  • Dec 01, 2018
  • Iranian Journal of Medical Physics
  • Malihe Rezaie Yazdi +6
  • PDF
  • Research Article
  • Citations1

Auxiliary Structures-Assisted Radiotherapy Improvement for Advanced Left Breast Cancer

  • Jul 08, 2021
  • Frontiers in Oncology
  • Runhong Lei +4
  • Research Article
  • Citations2

WE-D-224A-09: Proposed Pass/fail Criteria for IMRT Patient Specific QA

  • Jun 01, 2006
  • Medical Physics
  • C Yang +6
  • Research Article
  • Citations22

The effect of slice thickness on target and organs at risk volumes, dosimetric coverage and radiobiological impact in IMRT planning.

  • Aug 27, 2015
  • Clinical and Translational Oncology
  • S P Srivastava +2
  • PDF
  • Research Article
  • Citations18

Comparison of Dosimetric Gains Provided by Intensity-Modulated Radiotherapy, Volume-Modulated Arc Therapy, and Helical Tomotherapy for High-Grade Glioma

  • Jan 01, 2020
  • BioMed Research International
  • Pei Liu +10
  • Research Article
  • Citations55

RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation

  • Aug 03, 2010
  • Physics in Medicine & Biology
  • Sofie Ceberg +7
  • Research Article
  • Citations4

Patient-specific quality assurance of dynamically-collimated proton therapy treatment plans.

  • Jul 08, 2024
  • Medical physics
  • Laura C Bennett +16
  • Research Article
  • Citations2

Dosimetric comparison of VMAT standard optimization (SO) and multi‐criteria optimization (MCO) treatment plans with standard mode delivery (STD) or sliding window (SW) for head and neck cancer

  • May 05, 2023
  • Journal of Applied Clinical Medical Physics
  • Julien Rolland +4
  • PDF
  • Research Article

Dose Distribution Three-Dimensional Conformal Radiation Therapy (3DCRT) With 2 And 4 Directions in Treatment Planning System for Cervical Cancer Cases

  • Jul 08, 2024
  • International Journal of Scientific Research in Science and Technology
  • Armayta Krisnanjani +5
  • Research Article
  • Citations1

Optimizing normal tissue objectives (NTO) in eclipse treatment planning system (TPS) for stereotactic treatment of multiple brain metastases using non-coplanar RapidArc and comparison with HyperArc techniques.

  • Nov 06, 2024
  • Japanese journal of radiology
  • Sivakumar Muthu +1
  • Research Article

TH‐F‐105‐05: Comparison of Results for RBE‐Weighted Dose From Two RBE Models for Proton Therapy Treatment Plans

  • Jun 01, 2013
  • Medical Physics
  • C Peeler +5
  • Research Article

SU‐F‐T‐627: A Conformity Index Study of SBRT Plans for Lung Cancer Patient

  • Jun 01, 2016
  • Medical Physics
  • Dengsong Zhu +3
  • Abstract

222. Optimization of pretreatment IMRT dose distribution verification: Bidimensional gaussian kernel implementation

  • Dec 01, 2018
  • Physica Medica
  • F Errico +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.