WE‐AB‐207A‐07: A Planning CT‐Guided Scatter Artifact Correction Method for CBCT Images

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Purpose:Cone beam computed tomography (CBCT) imaging is on increasing demand for high‐performance image‐guided radiotherapy such as online tumor delineation and dose calculation. However, the current CBCT imaging has severe scatter artifacts and its current clinical application is therefore limited to patient setup based mainly on the bony structures. This study's purpose is to develop a CBCT artifact correction method.Methods:The proposed scatter correction method utilizes the planning CT to improve CBCT image quality. First, an image registration is used to match the planning CT with the CBCT to reduce the geometry difference between the two images. Then, the planning CT‐based prior information is entered into the Bayesian deconvolution framework to iteratively perform a scatter artifact correction for the CBCT mages. This technique was evaluated using Catphan phantoms with multiple inserts. Contrast‐to‐noise ratios (CNR) and signal‐to‐noise ratios (SNR), and the image spatial nonuniformity (ISN) in selected volume of interests (VOIs) were calculated to assess the proposed correction method.Results:Post scatter correction, the CNR increased by a factor of 1.96, 3.22, 3.20, 3.46, 3.44, 1.97 and 1.65, and the SNR increased by a factor 1.05, 2.09, 1.71, 3.95, 2.52, 1.54 and 1.84 for the Air, PMP, LDPE, Polystryrene, Acrylic, Delrin and Teflon inserts, respectively. The ISN decreased from 21.1% to 4.7% in the corrected images. All values of CNR, SNR and ISN in the corrected CBCT image were much closer to those in the planning CT images. The results demonstrated that the proposed method reduces the relevant artifacts and recovers CT numbers.Conclusion:We have developed a novel CBCT artifact correction method based on CT image, and demonstrated that the proposed CT‐guided correction method could significantly reduce scatter artifacts and improve the image quality. This method has great potential to correct CBCT images allowing its use in adaptive radiotherapy.

Similar Papers
  • Research Article
  • Citations38

Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions

  • Jul 30, 2011
  • Clinical Oral Investigations
  • Jun-Ge Cheng +5
  • PDF
  • Research Article
  • Citations5

Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study

  • Sep 25, 2020
  • Radiation Oncology
  • Jihun Kim +5
  • Research Article
  • Citations40

Accuracy of dose calculation based on artefact corrected Cone Beam CT images of lung cancer patients

  • Jan 01, 2017
  • Physics and Imaging in Radiation Oncology
  • Rune Slot Thing +3
  • Research Article

SU‐EE‐A4‐03: Spatial Resolution‐Matched Comparison Between Fan‐Beam and Cone‐Beam X‐Ray CT Images

  • Jun 01, 2006
  • Medical Physics
  • G Lasio +3
  • Research Article
  • Citations8

New technique and application of truncated CBCT processing in adaptive radiotherapy for breast cancer

  • Feb 01, 2023
  • Computer Methods and Programs in Biomedicine
  • Kai Xie +9
  • Research Article

SU‐FF‐J‐04: Improving Image Quality of Low Dose Cone Beam CT (CBCT) Imaging with Sparse Representation

  • Jun 01, 2009
  • Medical Physics
  • J Xia +2
  • Research Article
  • Citations10

A Study of the Anatomic Changes and Dosimetric Consequences in Adaptive CRT of Non-Small-Cell Lung Cancer Using Deformable CT and CBCT Image Registration

  • Apr 01, 2014
  • Technology in Cancer Research & Treatment
  • Changsheng Ma +6
  • Research Article
  • Citations122

Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard

  • Dec 09, 2010
  • Clinical Oral Implants Research
  • Livia Dos Santos Corpas +5
  • Research Article

Assessment of the effect of different imaging techniques on planning implant therapy by different clinicians

  • Jan 01, 2020
  • Annals of Medical Research
  • Duygu Bulut +1
  • Research Article

Evaluation of Homogeneity on Cone Beam Computed Tomography Imaging with Flat Panel Detector

  • Jan 01, 2009
  • Journal of Hard Tissue Biology
  • Noriyuki Sugino
  • Research Article
  • Citations7

Generating patient‐matched 3D‐printed pedicle screw and laminectomy drill guides from Cone Beam CT images: Studies in ovine and porcine cadavers

  • May 06, 2022
  • Medical Physics
  • Andrew Kanawati +4
  • Abstract

Pseudo CT Synthesis Using Cone-Beam CT of Cervical Cancer with GAN-Based Neural Network Model

  • Sep 29, 2023
  • International Journal of Radiation Oncology*Biology*Physics
  • H Yang +6
  • Research Article
  • Citations56

Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study

  • Dec 14, 2016
  • Journal of Endodontics
  • Funda Yılmaz +2
  • Research Article
  • Citations9

Use of gray values in CBCT and MSCT images for determination of density: influence of variation of FOV size.

  • Feb 19, 2015
  • Implant Dentistry
  • Andreia Fialho Rodrigues +4
  • Research Article

CT-guided CBCT multi-organ segmentation using a multi-channel conditional consistency diffusion model for lung cancer radiotherapy

  • Jun 20, 2025
  • Biomedical Physics & Engineering Express
  • Xiaoqian Chen +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.