Abstract

An investigation into the spatial resolving power of a castellated linear dual-energy x-ray detector array is reported. The detector was developed for use in aviation security screening applications. Experiments employing different gauges of lead wire are used to plot a wire transfer function. A numerical simulation is developed to predict and underpin the empirical results. The suitable processing of the castellated detector signals helps to maintain spatial resolving power while affording a 50% reduction in x-ray sensing elements. This encouraging result has formed the basis for an ongoing investigation into materials discrimination capability of the castellated detector array.

Similar Papers
  • Conference Article
  • Citations30

Preliminary results obtained from a novel CdZnTe pad detector and readout ASIC developed for an automatic baggage inspection system

  • Oct 15, 2000
  • T.O Tumer +14
  • Research Article
  • Citations20

Stereoscopic imaging using folded lineardual-energy x-ray detectors

  • Jul 31, 2002
  • Measurement Science and Technology
  • J P O Evans
  • Research Article
  • Citations88

Reconstruction of Axisymmetric Temperature and Gas Concentration Distributions by Combining Fan-Beam TDLAS With Onion-Peeling Deconvolution

  • Dec 01, 2014
  • IEEE Transactions on Instrumentation and Measurement
  • Chang Liu +3
  • Research Article
  • Citations1

Consideration of digital filtering during selection of parameters of multichannel continuously scanning digital X-ray radiography systems

  • Jan 01, 2008
  • Russian Journal of Nondestructive Testing
  • M B Lebedev +2
  • Conference Article
  • Citations1

A 16-channel avalanche photodiode detector array for visible and near-infrared flow cytometry

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • William G Lawrence +6
  • Conference Article

Enhanced resolution folded architecture spectral detector for fiber optic sensors

  • Jun 09, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Kenith E Meissner +3
  • Research Article
  • Citations45

Monte Carlo Calculations of the Detection Efficiency of Arrays of Nai(Tl), Bgo, Csf, Ge, and Plastic Detectors for 511 Kev Photons

  • Jan 01, 1981
  • IEEE Transactions on Nuclear Science
  • Stephen E Derenzo
  • PDF
  • Research Article

Dose Reduction in Medical Radiography: Advancing Veterinary Diagnostic Solutions

  • Jun 03, 2024
  • Qeios
  • Huseyin Yavuz Kocaova +2
  • Conference Article

Spin scan tomographic imager

  • May 26, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • H Hovland
  • Conference Article
  • Citations3

Characterization of a 32-element linear self-mixing detector array for an FM/cw ladar

  • Jul 29, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • William C Ruff +5
  • Research Article

Automatic Density Control for Increased Print Uniformity and Printer Reliability with Inline Linear Array Sensing

  • Jan 01, 2008
  • NIP & Digital Fabrication Conference
  • Howard Mizes +10
  • Conference Article
  • Citations4

Development of detailed design concepts for the EarthCARE multi-spectral imager

  • Nov 21, 2017
  • Mark Chang +3
  • Research Article
  • Citations2

Development of high-performance novel low-dimensional structure antimonide infrared FPAs: challenges and solutions

  • Mar 01, 2014
  • SCIENTIA SINICA Physica, Mechanica & Astronomica
  • Zhichuan Niu +2
  • Research Article
  • Citations11

Iterative reduction of gain variations in parallel electron energy loss spectrometry

  • Feb 01, 1993
  • Ultramicroscopy
  • Peter Schattschneider +1
  • Research Article
  • Citations1

Acousto-Optic Binary Data Recorder

  • Nov 01, 1987
  • Optical Engineering
  • P J Chantry +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.