- Research Article
5
- 10.1016/j.ijthermalsci.2024.109292
Effect of liquid-vapor two-phase flow maldistribution on the thermal performance of brazed plate heat exchangers
- Aug 05, 2024
- International Journal of Thermal Sciences
- Wenzhe Li + 1 more +1
Publications from 2021 to 2026
Showing 10 of 28 papers
Effect of liquid-vapor two-phase flow maldistribution on the thermal performance of brazed plate heat exchangers
End of selection criteria based on sexual orientation: An international symposium on alternatives to donation deferral.
Until recently, gay, bisexual and other men who have sex with men (MSM) were deferred from donating blood for 3-12 months since the last male-to-male sexual contact. This MSM deferral has been discontinued by several high-income countries (HIC) that now perform gender-neutral donor selection. An international symposium (held on 20-04-2023) gathered experts from seven HICs to (1) discuss how this paradigm shift might affect the mitigation strategies for transfusion-transmitted infections and (2) address the challenges related to gender-neutral donor selection. Most countries employed a similar approach for implementing a gender-neutral donor selection policy: key stakeholders were consulted; the transition was bridged by time-limited deferrals; donor compliance was monitored; and questions or remarks on anal sex and the number and/or type of sexual partners were often added. Many countries have now adopted a gender-neutral approach in which questions on pre- and post-exposure prophylaxis for human immunodeficiency virus (HIV) have been added (or retained, when already in place). Other countries used mitigation strategies, such as plasma quarantine or pathogen reduction technologies for plasma and/or platelets. The experience with gender-neutral donor selection has been largely positive among the countries covered herein and seems to be acceptable to stakeholders, donors and staff. The post-implementation surveillance data collected so far appear reassuring with regards to safety, although longer observation periods are necessary. The putative risks associated with HIV antiretrovirals should be further investigated.
Read moreAnomalous capillary flow of molten Al[sbnd]Si alloy and macrosegregation
Developing adiabatic two-phase flow after an expansion valve: the effect of tube diameter and oil
A mechanistic model in annular flow in microchannel tube for predicting heat transfer coefficient and pressure gradient
Part load performance of single and two stage compressors — a comparative experimental study in a R410A chiller unit
The rising cooling needs for the residential and commercial air conditioning sectors and the requirement of higher SEER values increased the focus on energy efficient part load performance. Although several studies exist on the topic of capacity modulation, there is no comprehensive study that compares different modulation strategies in the same experimental facility. In a first step, this paper aims to experimentally compare two different capacity controls for scroll compressors (single speed vs two stage compressor) using the same R410A water chiller having a nominal cooling capacity of 8kW. The tests were conducted according to AHRI Standard 551/591 (2018). The Integrated Part Load Value (IPLV.SI) was used to fairly compare all the different capacity modulation strategies. Based on the experimental results, differences on the order of 8% in IPLV.SI are found.
Read moreHeat Transfer Coefficient, Pressure Gradient, and Flow Patterns of R1234yf Evaporating in Microchannel Tube
Abstract This paper presents the heat transfer coefficient, pressure gradient, and flow pattern of R1234yf in a microchannel tube. Both heat transfer coefficient and pressure gradient are presented against real saturation pressure, while flow pattern captures at the exit of data points are presented in the same plot. The experiment was conducted on a 24-port microchannel tube with an average hydraulic diameter of 0.643 mm. The experiment covers mass flux from 100 to 200 kg m−2s−1, heat flux from 0 to 6 kW m−2, vapor quality from 0 to 1, and inlet saturation temperature from 10 to 30 °C. Comparing the correlations to the HTC measurements at very low quality (about 0.1), Gorenflo, D., and Kenning, D. (2010, Pool Boiling, in: VDI Heat Atlas, 2nd ed, Springer, pp. 757–788) agree with the results. As vapor quality increases, pressure gradient increases. The adiabatic pressure gradient is a strong function of mass flux and saturation pressure (temperature). Flow patterns of R1234yf are also affected by mass flux and saturation pressure. The heat transfer coefficient is a strong function of mass flux and heat flux. The saturation temperature has a smaller effect on HTC in the condition range (10 – 30 °C). Under the test range, the accelerating pressure drop is insignificant compared to friction. Comparing to the results, Mishima, K., and Hibiki, T. (1996, “Some Characteristics of Air-Water Two-Phase Flow in Small Diameter Vertical Tubes,” Int. J. Multiph. Flow, 22(4), pp. 703–712) and Muller-Steinhagen, H., and Heck, K. (1986, “A Simple Friction Pressure Drop Correlation for Two-Phase Flow in Pipes,” Accessed March 1, 2018)., 20, pp. 297–308.) have small mean absolute error (MAE) to predict local pressure gradient. For the heat transfer coefficient, Sun, L., and Mishima, K. (2009, “An Evaluation of Prediction Methods for Saturated Flow Boiling Heat Transfer in Mini-Channels,” Int. J. Heat Mass Transf, 52(23–24), pp. 5323–5329) and Gungor, K. E., and Winterton, R. H. S. (1986, “A General Correlation for Flow Boiling in Tubes and Annuli,” Int. J. Heat Mass Transf, 29(3), pp. 351–358) have an MAE less than 30%.
Read moreCompensating for the end-plate effect on heat transfer in brazed plate heat exchangers
Experimental study on forced convection hydraulic and thermal characteristics in a dimpled flat duct
Visualization of R410A Flow Boiling Inside Horizontal Smooth Tubes under Diabatic Conditions