- Research Article
2
- 10.1016/j.bpobgyn.2024.102538
Reframing antepartum and intrapartum surveillance
- Sep 10, 2024
- Best Practice & Research Clinical Obstetrics & Gynaecology
- Lawrence D Devoe + 2 more +2
Publications from 2021 to 2026
Showing 10 of 22 papers
Reframing antepartum and intrapartum surveillance
Antenatal steroids elicited neurodegenerative-associated transcriptional changes in the hippocampus of preterm fetal sheep independent of lung maturation
BackgroundAntenatal steroid therapy for fetal lung maturation is routinely administered to women at risk of preterm delivery. There is strong evidence to demonstrate benefit from antenatal steroids in terms of survival and respiratory disease, notably in infants delivered at or below 32 weeks’ gestation. However, dosing remains unoptimized and lung benefits are highly variable. Current treatment regimens generate high-concentration, pulsatile fetal steroid exposures now associated with increased risk of childhood neurodevelopmental diseases. We hypothesized that damage-associated changes in the fetal hippocampal transcriptome would be independent of preterm lung function.MethodsDate-mated ewes carrying a single fetus at 122 ± 2dGA (term = 150dGA) were randomized into 4 groups: (i) Saline Control Group, 4×2ml maternal saline intramuscular(IM) injections at 12hr intervals (n = 11); or (ii) Dex High Group, 2×12mg maternal IM dexamethasone phosphate injections at 12hr intervals followed by 2×2ml IM saline injections at 12hr intervals (n = 12; representing a clinical regimen used in Singapore); or (iii) Dex Low Group, 4×1.5mg maternal IM dexamethasone phosphate injections 12hr intervals (n = 12); or (iv) Beta-Acetate Group, 1×0.125mg/kg maternal IM betamethasone acetate injection followed by 3×2ml IM sterile normal saline injections 12hr intervals (n = 8). Lambs were surgically delivered 48hr after first maternal injection at 122–125dGA, ventilated for 30min to establish lung function, and euthanised for necropsy and tissue collection.ResultsPreterm lambs from the Dex Low and Beta-Acetate Groups had statistically and biologically significant lung function improvements (measured by gas exchange, lung compliance). Compared to the Saline Control Group, hippocampal transcriptomic data identified 879 differentially significant expressed genes (at least 1.5-fold change and FDR < 5%) in the steroid-treated groups. Pulsatile dexamethasone-only exposed groups (Dex High and Dex Low) had three common positively enriched differentially expressed pathways related in part to neurodegeneration (“Prion Disease”, “Alzheimer’s Disease”, “Arachidonic Acid metabolism”). Adverse changes were independent of respiratory function during ventilation.ConclusionsOur data suggests that exposure to antenatal steroid therapy is an independent cause of damage- associated transcriptomic changes in the brain of preterm, fetal sheep. These data highlight an urgent need for careful reconsideration and balancing of how antenatal steroids are used, both for patient selection and dosing regimens.
Read more157 Another reason to address social determinants and disparities: It saves money
Invasive Procedures in the First Trimester
Combined prenatal and postnatal prediction of early neonatal compromise risk
Objective Electronic fetal monitoring/cardiotocography (EFM) is nearly ubiquitous, but almost everyone acknowledges there is room for improvement. We have contextualized monitoring by breaking it down into quantifiable components and adding to that, other factors that have not been formally used: i.e. the assessment of uterine contractions, and the presence of maternal, fetal, and obstetrical risk factors. We have created an algorithm, the Fetal Reserve Index (FRI) that significantly improves the detection of at-risk cases. We hypothesized that extending our approach of monitoring to include the immediate newborn period could help us better understand the physiology and pathophysiology of the decrease in fetal reserve during labor and the transition from fetal to neonatal homeostasis, thereby further honing the prediction of outcomes. Such improved and earlier understanding could then potentiate earlier, and more targeted use of neuroprotective attempts during labor treating decreased fetal reserve and improving the fetus’ transition from fetal to neonatal life minimizing risk of neurologic injury. Study design We have analyzed a 45-year-old research database of closely monitored labors, deliveries, and an additional hour of continuous neonatal surveillance. We applied the FRI prenatally and created a new metric, the INCHON index that combines the last FRI with umbilical cord blood and 4-minute umbilical artery blood parameters to predict later neonatal acid/base balance. Using the last FRI scores, we created 3 neonatal groups. Umbilical cord and catheterized umbilical artery bloods at 4, 8, 16, 32, and 64 minutes were measured for base excess, pH, and PO2. Continuous neonatal heart rate was scored for rate, variability, and reactivity. Results Neonates commonly do not make a smooth transition from fetal to postnatal physiology. Even in low risk babies, 85% exhibited worsening pH and base excess during the first 4 minutes; 34% of neonates reached levels considered at high risk for metabolic acidosis (≤−12 mmol/L) and neurologic injury. Neonatal heart rate commonly exhibited sustained, significant tachycardia with loss of reactivity and variability. One quarter of all cases would be considered Category III if part of the fetal tracing. Our developed metrics (FRI and INCHON) clearly discriminated and predicted low, medium, and high-risk neonatal physiology. Conclusions The immediate neonatal period often imposes generally unrecognized risks for the newborn. INCHON improves identification of decreased fetal reserve and babies at risk, thereby permitting earlier intervention during labor (intrauterine resuscitation) or potentially postnatally (brain cooling) to prevent neurologic injury. We believe that perinatal management would be improved by routine, continuous neonatal monitoring – at least until heart rate reactivity is restored. FRI and INCHON can help identify problems much earlier and more accurately than currently and keep fetuses and babies in better metabolic shape.
Read moreFirst trimester screening for major cardiac defects based on the ductus venosus flow in fetuses with trisomy 21.
To examine whether in fetuses with trisomy 21 (T21), the ductus venosus (DV) flow differs in presence of a major cardiac defect (congenital cardiac defect [CHD]) and whether this affects the risk distribution in first trimester screening for T21. This retrospective study included pregnant women who underwent first trimester screening. This involves an examination of the crown-rump length, the nuchal translucency, the ductus venosus (DV) flow, and the heart. Three groups of fetuses were examined: euploid without CHD, T21 with CHD, and T21 without CHD. We examined the DV pulsatility index for veins, the direction of the a-wave, and ratios of velocities: v/S, v/D, a/S, a/D, and S/D. The study population consisted of 410 euploid fetuses and 136 with T21 (51 with CHD and 85 without CHD). In the 3 groups, the a-wave was reversed in 3.2%, 66.7%, and 57.6%. The DV flow ratios in T21 with and without CDH were significantly different compared with normal fetuses. When comparing the ratios between the 2T21 groups, only the a/S and a/D ratio were significantly different. The risk distributions in screening for T21 with and without CDH were similar. There are some small differences in the DV flow of T21 fetuses with and without CHD, but they are not clinically useful.
Read moreReengineering Electronic Fetal Monitoring Interpretation: Using the Fetal Reserve Index to Anticipate the Need for Emergent Operative Delivery.
The near-ubiquitous use of electronic fetal monitoring has failed to lower the rates of both cerebral palsy and emergency operative deliveries (EODs). Its performance metrics have low sensitivity, specificity, and predictive values for both. There are many EODs, but the vast majority have normal outcomes. The EODs, however, cause serious disruption in the delivery suite routine with increased complications, anxiety, and concern for all. We developed the fetal reserve index (FRI) as multicomponent algorithm including 4 FHR components (analyzed individually), uterine activity, and maternal, obstetrical, and fetal risk factors to assess risk of cerebral palsy and EOD. Scores were categorized into green, yellow, and red zones. Here, we studied 300 patients by the FRI, all of whom had normal neonatal outcomes. We attempted to distinguish the clinical course of those cases which required an EOD versus controls which did not. 51 cases with EOD had FRIs much lower than 249 non-EOD cases. The red zone was reached more frequently ( P < .001) and lasted longer (1.06 vs 0.05 hours; P < .001). Reaching the red zone had a sensitivity of 92% for EOD, with a positive predictive value of 64% and a false positive rate of 10.4%. Our data suggest the FRI can significantly lower the incidence of EODs by identifying the opportunity for intrauterine resuscitation. Our approach can reduce the disruptive effects of EODs and their concomitant increased risks of complications. The FRI may provide a metric that can refine labor management to reduce CP and EODs.
Read moreFirst-trimester risk assessment based on ultrasound and cell-free DNA vs combined screening: a randomized controlled trial.
This was a randomized controlled trial to compare risk assessment by first-trimester combined screening (FTCS) with an approach that combines a detailed ultrasound examination at 11-13 weeks' gestation and cell-free DNA (cfDNA) analysis. Pregnant women with a normal first-trimester ultrasound examination at 11-13 weeks' gestation (fetal nuchal translucency (NT)≤ 3.5 mm and no fetal defects) were randomized into one of two groups. In the first group, risk of aneuploidy was assessed using FTCS based on the most recent UK Fetal Medicine Foundation algorithm. In the second group, risk assessment was based on ultrasound findings and cfDNA analysis. An additional tube of blood was collected for FTCS in case the cfDNA analysis was uninformative. Primary outcome was false-positive rate in screening for trisomy 21. A case was considered false positive if the karyotype was not trisomy 21 and if the risk for trisomy 21 was >1:100, irrespective of the method of risk calculation. Results were compared using 95% CIs using the Clopper-Pearson method. Between October 2015 and December 2016, 1518 women with singleton pregnancy underwent first-trimester screening. Thirty-one (2.0%) pregnancies were not eligible for randomization due to increased NT (> 3.5 mm) and/or fetal defect. After exclusion of women who declined randomization (n= 87) and cases of fetal death and loss to follow-up (n= 24), 688 pregnancies were randomized into the FTCS arm and 688 into the ultrasound + cfDNA analysis arm. There were no differences in maternal and gestational age, maternal weight and BMI, ethnicity, use of assisted reproduction and cigarette smoking between the two arms. In the ultrasound + cfDNA analysis arm, median risk for trisomy 21 was 1 in 10 000. None of the cases had a risk above 1: 100 (95% CI, 0.0-0.5%). In the FTCS arm, the median risk for trisomy 21 was 1 in 3787 and in 17 cases, the risk was higher than 1:100, which corresponds to 2.5% (95% CI, 1.5-3.9%) of the FTCS study-arm population. Our study has shown that first-trimester risk assessment for trisomy 21 that includes a detailed ultrasound examination as well as NT measurement and is followed by cfDNA testing is associated with a significant reduction in the false-positive rate compared with FTCS. This approach obviates the need for maternal serum free β-human chorionic gonadotropin and pregnancy-associated plasma protein-A in screening for fetal aneuploidy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Read moreRe-engineering the interpretation of electronic fetal monitoring to identify reversible risk for cerebral palsy: a case control series
Background: Even key opinion leaders now concede that electronic fetal monitoring (EFM) cannot reliably identify fetal acidemia which many vouch as the only labor mediated pathophysiologic precursor for cerebral palsy (CP). We have developed the “Fetal Reserve Index” – an algorithm combining five dynamic components of EFM (1. Rate, 2. Variability, 3. Accelerations, 4. Decelerations, and 5. Excessive uterine activity) considered individually that are combined with the presence of: 6. maternal, 7. obstetrical, and 8. fetal risk factors. Objective: Here, we compare this 8-point fetal reserve index (FRI) against the performance of ACOG monograph criteria and ACOG Category systems for predicting risk for both CP and the need for emergency operative delivery (EOD). We then studied how varied management for screen positives (Red zone-defined below) impacts the outcome of such cases. Study design: Four hundred twenty term patients were studied: all entered labor with normal EFMs and no apparent cause of harm except events of labor and delivery. Sixty subsequently developed CP, and 360 were apparently normal controls. An FRI, normal on all eight parameters scored 100%, 4 of the 8 was 50%, etc. We divided cases into Green zone >50%, Yellow 50–26%, and Red ≤25%. An FRI in the Red zone was considered a positive screen. We then compared performance metrics for the three evaluation schemes and differences between controls that reached Red against those controls whose worst scores were Green/Yellow. Results: For detection of injury during labor, the FRI performed much better than the ACOG Category criteria (sensitivity 28%), and Category III (45%) (p < .001). All CP cases reached Red zone and were Red for a minimum of 2 hours (mean = 5.35 hours). Twenty-four% of controls reached Red, but were only Red for average of 1 hr. The incidence of low Apgar’s, pH, FRI, and Lowest FRI increased progressively from Green/Yellow controls to red controls to CP cases. Irrespective, CP cases met ACOG Monograph criteria for labor injury less than 50% of the time. Only half of CP babies had umbilical artery pH values <7.00, and less than 50% showed Category III patterns. The earlier in labor the Red zone was reached, the more likely for a baby to develop CP or the mother to require an EOD regardless of fetal outcome. Successful intrauterine resuscitations (IR) diminished time spent in the Red zone and the need for EODs. Conclusions: FRI shows better discrimination for adverse fetal outcome and EOD than traditional EFM interpretation. The Category system is a very poor, subjective screening method as the vast majority of CP babies never reach the “action point” result of Category III. While reaching the Red zone does not ordain a bad outcome, how it is managed, does. Compared to CP cases, Red controls were delivered faster, had higher FRIs, and often had prompt management including IR maneuvers, which improved the FRI and lowered the risk of EODs even for cases with normal outcomes. With further study and validation, the quantitative FRI approach may replace the current, very subjective interpretation with a quantitative “lab test” approach.
Read morePrinciples of first trimester screening in the age of non-invasive prenatal diagnosis: screening for other major defects and pregnancy complications.
First trimester risk assessment plays a major role in the contemporary pregnancy care. It has evolved significantly since its introduction in the 1990s when it essentially consisted of just the nuchal translucency measurement. Today, it involves the measurement of several biophysical and biochemical markers and can assess the risk for a wide array of major chromosomal and non-chromosomal defects as well as other pregnancy-related complications. A search of the Medline and Embase databases was done looking for articles about first trimester screening. We performed a detailed review of the literature to evaluate the screening tests currently available and their respective test performance. The detailed ultrasound examination results in the detection of about half of major structural defects, determination of a very accurate gestational age, and identification of multiple pregnancies as well as their chorionicity. In addition, risk assessment for preeclampsia and early IUGR can be established at this stage. In case of an increased risk, the daily use of low-dose aspirin can be offered at a point in pregnancy when it still can have a positive impact. Additional screening tests for gestational diabetes and macrosomia are available. Contemporary first trimester screening is essential to establish an individual risk profile and can be used to tailor the pregnancy care.
Read more