- Supplementary Content
- 10.1002/jia2.70086
Integrating postal HIV testing into the HIV care cascade in Japan: a public health centre model
- Feb 15, 2026
- Journal of the International AIDS Society
- Kota Iwahashi + 4 more +4
Publications from 2021 to 2026
Showing 10 of 67 papers
Integrating postal HIV testing into the HIV care cascade in Japan: a public health centre model
Chebyshev polynomial-based higher-order derivatives estimation from an encoder
Prefecture-Level Projections for COVID-19 Hospital Bed Demand in Japan
Preparation of PVA-based charged mosaic membrane using screen-printed method and evaluation of ion transport properties
In this study, a polyvinyl alcohol (PVA)-based charged mosaic membrane (CMM) with a stripe-shaped charged structure from PVA-modified block copolymers was fabricated on a non-fabric support using a screen-printed method. The membrane structure of the stained CMM indicated that the striped negatively (N)- and positively (P)-charged layers with 20 μ m thickness were formed on the support. The domain sizes of the N and P layers were 173 and 203 μ m, respectively. Membrane potential measurements revealed that the charge density in the N layers of the fabricated CMM (CM-1) was almost the same as that in the P layers. A diffusion dialysis test indicated that the CM-1 had an electrolyte permselectivity of 986 between 0.1 M KCl and 0.1 M sucrose; a value which is approximately 20 times higher than that of Desalton® which is the only commercially available CMM. A water permeation test showed that CM-1 exhibited negative osmosis, which is a unique behavior of CMMs with high electrolyte permselectivity. Absolute flux in the negative osmosis was maximum when the electrolyte concentration was 0.1 M. A piezo dialysis test at an initial concentration of 500 ppm NaCl and applied pressure of 0.7 MPa, indicated that the rejection of CM-1 yielded negative value, confirming that the membrane can desalt salty water via piezo dialysis.
Read moreReview of Research and Development of High Permeability Hollow Fiber Membrane Module for High SS Water
Outer layer scintillating fiber for low-energy β-ray detection.
Standard plastic scintillating fiber cannot detect low-energy β-rays as the cladding prevents them from reaching the fiber core. We developed an outer-layer scintillating (OLS) fiber with a plastic scintillator on the outermost layer for low-energy β-ray detection. The concept of fiber construction is presented. The fundamental optical properties of the OLS fiber, such as the emission spectrum, attenuation length, and scintillation decay time, were evaluated. Here, Ni-63 with a maximum energy of 67.0keV was used as a low-energy β-emitting nuclide. Simulation studies on the interaction between low-energy electrons emitted from Ni-63 and a single fiber were performed prior to actual measurements. The data showed that Ni-63 can be measured using silicon photomultiplier photosensors in a coincidence mode. The OLS fiber was effective for low-energy β-ray detection.
Read moreSilane-modified low molecular weight ‘liquid’ polymers in sulfur cured mixtures of styrene-butadiene copolymers and silica
Silane coupling agents are used in silica filled rubber compounds to increase the filer-polymer interactions and to lower the filler-filer interactions. In addition, silane functionalized polymers can be used. Special types of polymers are low molecular weight ‘liquid’ polymers. The goal of this paper is to obtain more understanding about the uses and effects of these low molecular weight ‘liquid’ polymers in combination with silanes and other compound components. Three different silane coupling agents and six different low molecular weight ‘liquid’ polymers were selected, evaluated and comparatively introduced in mixtures of a SSBR/silica compound. The Payne effect was measured to evaluate the strain dependence of the mixtures. It was used to evaluate the filler-filler interactions and estimate the micro dispersion. This provides information about the interactions and the building of additional networks that comprises the low molecular weight ‘liquid’ polymer together with the silica, silane and main polymer. Results of dynamic mechanical analysis are discussed. The microstructures and silane-functionalizations show clear dependences on the glass transition temperatures, loss moduli and tan δ values.
Read moreEffect of moisture conservation technology in cultivation of brinjal under rainfed condition of Bundelkhand region
An adaptive research on effect of moisture conservation technology in cultivation of brinjal under rainfed condition of bundelkhand region was carried out by following randomized complete block design in participatory mode with 10 famers having three technology options (Plastic mulch, Straw mulch and No mulch) of Hamirpur district of Uttar Pradesh during cropping seasons of kharif, 2018-19 and 2019-20. The observations recorded revealed that the highest saving on weed management and water management were observed in plastic mulching followed by straw mulching. Fruit yield and benefit: cost ratio were also recorded higher in crop having mulch (plastic followed by straw) than no mulch. On the basis of observations recorded it was concluded that mulching is a useful technique to minimize the competition between crop and weed and water stress during long rainfall interval. This technique may help the farmers to minimize the cost of cultivation and maximize more benefits.
Read moreMagnetic resonance imaging parameters relate with recovery time from muscle strain among professional football players
The purpose of this study was to investigate the relationship between imaging parameters of magnetic resonance imaging and recovery time from muscle strain of the lower extremities among professional football players. A total of 42 injuries from 24 male professional football players, who sustained lower extremity muscle strain, were included in the study. The longitudinal length of the injury and percentage of cross-sectional involvement were measured using the magnetic resonance imaging. The percentage of the cross-sectional involvement was defined as (a) under 25%, (b) over 25 to 50%, (c) over 50%-75%, and (d) over 75%. Imaging parameters were statistically analyzed between recovery time. Average recovery time was 22.2 days. The most injured muscle was the biceps femoris with 21 cases, 50%. The average longitudinal length of the injury was 10.7 cm. Average recovery time correlated significantly with the longitudinal length of the injury. Average recovery time became significantly greater among players with the cross-sectional involvement of over 50% compared with the players with percentage under 25%. Imaging parameters of longitudinal length and percentage of cross-sectional involvement related to recovery time until return to play from lower extremity muscle strain among professional football players.
Read morePreparation of Polyamide Thin-Film Composite Membranes Using Hydrophilic Hollow Fiber PVDF via the TIPS Process Modified by PVA Diffusion
We developed a new hydrophilization method that we refer to as polyvinylalcohol (PVA) diffusion. This new method modifies the entire surface area of a hollow fiber membrane by diffusing PVA from the bore fluid to the outer surface. This method was used to prepare hydrophilized polyvinylidene difluoride (PVDF) hollow fiber membranes (PVA–PVDF). A hydrophilized polysulfone (PSf) hollow fiber membrane (PVA–PSf) was also prepared for reference. Interfacial polymerization was performed on the outer surface of the hollow fiber substrates during the preparation of polyamide (PA) thin-film composite membranes. This study examined the hydrophilicity effect that these modified support layers exert on the performance of membranes during reverse osmosis (RO) and forward osmosis (FO). Compared with PSf membranes, PVDF membranes had a higher physical strength of over 10 MPa, which was credited to production using a thermally induced phase separation (TIPS) process compared to the non-solvent induced phase separation (NIPS) process that is used to produce PSf membranes. The TIPS process could be useful for developing mass production techniques such as roll-to-roll processing. Comparisons of the RO test performance of hydrophilized PVDF membranes (PA–PVA–PVDF, PA–PVDF) showed that the 1000 ppm of NaCl rejection of hydrophilized support membrane was higher than that of nonmodified support membranes. The FO performances were similar regardless of whether or not the support membranes were hydrophilized when measured under wet conditions. In measurements under dry conditions, however, the performance was significantly lowered in the PA–PVDF membrane that was not hydrophilized. Hydrophilization via PVA diffusion effectively produced equivalent FO membrane performances under either wet conditions or dry conditions.
Read more