- Conference Article
- 10.1109/prime66228.2025.11203629
Read-Out and Electrical Connection of Modern High-Purity Germanium Detectors: Innovative Flexible Systems and Integrated Charge-Sensitive Pre-amplifiers
- Sep 21, 2025
- Giacomo Secci + 6 more +6
Publications from 2021 to 2026
Showing 10 of 384 papers
Read-Out and Electrical Connection of Modern High-Purity Germanium Detectors: Innovative Flexible Systems and Integrated Charge-Sensitive Pre-amplifiers
Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter
We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz.
Read moreDesign of an E × B Chopper System Based on Permanent Magnets for the Injection Line of the SPES Project Cyclotron
This paper presents the requirements and design solutions of the chopper for the injection line of the cyclotron of the SPES project at Laboratori Nazionali di Legnaro. The device aims to precisely modulate the average current injected into the cyclotron, thereby controlling the current it delivers. A precise control of the beam current is essential for many experiments foreseen for the cyclotron. Due to safety constraints and limited space, a tailored design has been developed. The chopper features a Wien filter configuration, where the electric field is pulsed and the magnetic field is generated by permanent magnets.
Read moreComparative analysis of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>R</mml:mi></mml:math> -matrix fitting: <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mmultiscripts><mml:mi mathvariant="normal">C</mml:mi><mml:mprescripts/><mml:none/><mml:mn>12</mml:mn></mml:mmultiscripts><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>γ</mml:mi><mml:mo>)</mml:mo><mml:mmultiscripts><mml:mi mathvariant="normal">N</mml:mi><mml:mprescripts/><mml:none/><mml:mn>13</mml:mn></mml:mmultiscripts></mml:mrow></mml:math> as a test case
In nuclear astrophysics, the accurate determination of nuclear reaction cross sections at astrophysical energies is critical for understanding stellar evolution and nucleosynthesis. This study focuses on the $^{12}\mathrm{C}(p,\ensuremath{\gamma})^{13}\mathrm{N}$ reaction, which takes part in the CNO cycle and is significant for determining the $^{12}\mathrm{C}/^{13}\mathrm{C}$ ratio in stellar interiors. Data from various studies, including recent LUNA measurements, reveal high discrepancies in cross-section values, underscoring the need for robust fitting approaches. Utilizing the R-matrix theory, we compare different frequentist and Bayesian methodologies for estimating reaction cross sections and their uncertainties. The analysis evaluates the strengths and weaknesses of different statistical techniques, highlighting the importance of systematic uncertainty treatment and the estimate of covariance matrix estimation to enhance the reliability and reproducibility of uncertainty estimates in nuclear astrophysics.
Read moreMeasurement of the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mmultiscripts><mml:mi>Yb</mml:mi><mml:mprescripts/><mml:none/><mml:mn>176</mml:mn></mml:mmultiscripts><mml:mo>(</mml:mo><mml:mi>n</mml:mi><mml:mo>,</mml:mo><mml:mi>γ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math> cross section at the n_TOF facility at CERN
The Yb176(n,γ)Yb177→Lu177 reaction is of interest in nuclear medicine as it is the preferred production route for Lu177. This radioisotope has seen a very fast growth of usage in nuclear medicine in recent years due to its outstanding properties. New data on this reaction could provide useful information for production at new facilities. We aim to resolve resonances in the Yb176(n,γ)Yb177 reaction for the first time. Previous capture measurement provided data at thermal point and encompassed integral measurements in the range from 3 keV to 1 MeV, where three time-of-flight measurements are available, but with low resolution to resolve the resonances. Transmission measurements from the 1970s resolved and analyzed some resonances. We measure the neutron capture cross section of Yb176(n,γ)Yb177 by means of the time-of-flight technique at the Experimental Area 1 of the n_TOF facility at CERN using an enriched Yb1762O3 sample and an array of four C6D6 liquid scintillation detectors. We have resolved 164 resonances up to 21 keV, including 96 new ones. We also provide new capture experimental data from 90 eV to 3 keV, and we extend the resolved resonance region up to 21 keV. In addition, resonance decay widths, Γγ and Γn, are provided for all resonances together with resonance energies. The Yb176(n,γ)Yb177 reaction has been measured, providing resonance parameters for the first time from a few eV to 21 keV. The analysis of the resonances has been carried out and compared with previous works and existing libraries, revealing discrepancies due to the new information on Γγ parameters. Our results are consistent with the Γn parameters obtained in transmission measurements.Published by the American Physical Society2024
Read moreMeasurement of the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mmultiscripts><mml:mi>Se</mml:mi><mml:mprescripts/><mml:none/><mml:mn>78</mml:mn></mml:mmultiscripts><mml:mo>(</mml:mo><mml:mi>n</mml:mi><mml:mo>,</mml:mo><mml:mi>γ</mml:mi><mml:mo>)</mml:mo><mml:mmultiscripts><mml:mi>Se</mml:mi><mml:mprescripts/><mml:none/><mml:mn>79</mml:mn></mml:mmultiscripts></mml:mrow></mml:math> cross section up to 600 keV at the n_TOF facility at CERN
The Se78(n,γ)Se79 cross section has a high impact on the abundances of Se78 produced during the slow neutron capture process (s process) in massive stars. A measurement of the Se78 radiative neutron capture cross section has been performed at the Neutron Time-of-Flight facility at CERN using a set of liquid scintillation detectors that have been optimized for a low sensitivity to neutrons. We present resonance capture kernels up to 70 keV and cross section from 70 to 600 keV. Maxwellian-averaged cross section (MACS) values were calculated for stellar temperatures between kT=5 and 100 keV, with uncertainties between 4.6% and 5.8%. The new MACS values result in substantial decreases of 20–30% of Se78 abundances produced in the s process in massive stars and AGB stars. Massive stars are now predicted to produce subsolar Se78/Se76 ratios, which is expected since Se76 is an s-only isotope, while solar Se78 abundances have also contributions from other nucleosynthesis processes. Published by the American Physical Society 2024
Read moreSearch for Fractionally Charged Particles with CUORE
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5 cm×5 cm×5 cm TeO2 crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in Te130. Unprecedented in size among cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic throughgoing particles. Using the first tonne year of CUORE’s exposure, we perform a search for hypothesized (FCPs), which are well-motivated by various standard model extensions and would have suppressed interactions with matter. Across the searched range of charges e/24−e/2 no excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges e/24−e/5 at 90% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale subkelvin detectors to diverse signatures of new physics. Published by the American Physical Society 2024
Read moreCollectivity at the prolate-oblate transition: The [formula omitted] lifetime of 190W
The neutron-rich rare isotope 190W is discussed as a candidate for a prolate-oblate transitional nucleus with maximum γ-softness. The collectivity of this isotope is assessed for the first time by the measurement of the reduced E2 transition probability of its first 2+ state to the ground state. The experiment employed the FAst TIming Array (FATIMA), comprised of 36 LaBr3(Ce) scintillators, which was part of the DESPEC setup at GSI, Darmstadt. The 41+ and 21+ states of 190W were populated subsequently to the decay of its 127(12) μs isomeric Jπ=10− state. The mean lifetime of the 21+ state was determined to be τ=274(28) ps, which corresponds to a B(E2;21+→01+) value of 95(10) W.u. The results motivated a revision of previous calculations within an energy-density functional-based interacting boson model-2 approach, yielding E2 transition properties and spectroscopic quadrupole moments for tungsten isotopes. From comparison to theory, the new data suggest that 190W is at the transition from prolate to oblate structure along the W isotopic chain, which had previously been discussed as a nuclear shape-phase transition.
Read moreHighly porous carbon-SiC composites with continuous carbon fibers for the production of radioisotopes in ISOL facilities
155Tb production by cyclotrons: what level of 155Gd enrichment allows clinical applications?
Background155Tb represents a potentially useful radionuclide for diagnostic medical applications, but its production remains a challenging problem, in spite of the fact that many production routes have been already investigated and tested. A recent experimental campaign, conducted with low-energy proton beams impinging on a 155Gd target with 91.9% enrichment, demonstrated a significant co-production of 156gTb, a contaminant of great concern since its half-life is comparable to that of 155Tb and its high-energy γ emissions severely impact on the dose released and on the quality of the SPECT images. In the present investigation, the isotopic purity of the enriched 155Gd target necessary to minimize the co-production of contaminant radioisotopes, in particular 156gTb, was explored using various computational simulations.ResultsStarting from the recent experimental data obtained with a 91.9% 155Gd-enriched target, the co-production of other Tb radioisotopes besides 155Tb has been theoretically evaluated using the Talys code. It was found that 156Gd, with an isotopic content of 5.87%, was the principal contributor to the co-production of 156gTb. The analysis also demonstrated that the maximum amount of 156Gd admissible for 155Tb production with a radionuclidic purity higher than 99% was 1%. A less stringent condition was obtained through computational dosimetry analysis, suggesting that a 2% content of 156Gd in the target can be tolerated to limit the dose increase to the patient below the 10% limit. Moreover, it has been demonstrated that the imaging properties of the produced 155Tb are not severely affected by this level of impurity in the target.Conclusions155Tb can be produced with a quality suitable for medical applications using low-energy proton beams and 155Gd-enriched targets, if the 156Gd impurity content does not exceed 2%. Under these conditions, the dose increase due to the presence of contaminant radioisotopes remains below the 10% limit and good quality images, comparable to those of 111In, are guaranteed.
Read more