- Research Article
- 10.1007/s12268-025-2492-y
Bakterien schützen Vögel vor Pathogenen
- Jun 01, 2025
- BIOspektrum
- Elena Seibel
Publications from 2021 to 2026
Showing 10 of 18 papers
Bakterien schützen Vögel vor Pathogenen
High-throughput manufacturing of transparent fused silica glass by injection molding and extrusion
Due to high optical transparency combined with high thermal and chemical stability transparent fused silica glass is of high interest for many applications in microsystems engineering, especially in the field of microfluidics and micro optics. However, structuring of fused silica is inherently difficult and usually includes high temperatures, complicated and toxic etching processes or time consuming grinding protocols with severe limitation to freedom of design and manufacturing speed. Thus, complex structured fused silica glass has been limited especially on the industrial scale. We developed highly filled, thermoplastic fused silica nanocomposites (so-called Glassomers), that can be processed using commonly available high-throughput polymer manufacturing technologies such as injection molding or continuous extrusion. After the shaping process the thermoplastic Glassomer is converted to pure, transparent glass by subsequent debinding and sintering yielding high-quality fused silica glass with high optical transparency (transmission >90 %) and optical surface quality (R<sub>q</sub> < 5 nm). We show injection molding of high-resolution microstructures as well as complex shaped macroscopic components that are subsequently converted to pure fused silica glass enabling for the first time mass-market manufacturing of fused silica glass components, enabling a plethora of applications in micro optics and lab-on-a-chip devices.
Read moreDeterministic Lateral Displacement: Challenges and Perspectives.
The advent of microfluidics in the 1990s promised a revolution in multiple industries from healthcare to chemical processing. Deterministic lateral displacement (DLD) is a continuous-flow microfluidic particle separation method discovered in 2004 that has been applied successfully and widely to the separation of blood cells, yeast, spores, bacteria, viruses, DNA, droplets, and more. Deterministic lateral displacement is conceptually simple and can deliver consistent performance over a wide range of flow rates and particle concentrations. Despite wide use and in-depth study, DLD has not yet been fully elucidated or optimized, with different approaches to the same problem yielding varying results. We endeavor here to provide up-to-date expert opinion on the state-of-art and current fundamental, practical, and commercial challenges with DLD as well as describe experimental and modeling opportunities. Because these challenges and opportunities arise from constraints on hydrodynamics, fabrication, and operation at the micro- and nanoscale, we expect this Perspective to serve as a guide for the broader micro- and nanofluidic community to identify and to address open questions in the field.
Read moreEmbedded Disposable Functionalized Electrochemical Biosensor with a 3D-Printed Flow Cell for Detection of Hepatic Oval Cells (HOCs).
Hepatic oval cells (HOCs) are considered the progeny of the intrahepatic stem cells that are found in a small population in the liver after hepatocyte proliferation is inhibited. Due to their small number, isolation and capture of these cells constitute a challenging task for immunosensor technology. This work describes the development of a 3D-printed continuous flow system and exploits disposable screen-printed electrodes for the rapid detection of HOCs that over-express the OV6 marker on their membrane. Multiwall carbon nanotube (MWCNT) electrodes have a chitosan film that serves as a scaffold for the immobilization of oval cell marker antibodies (anti-OV6-Ab), which enhance the sensitivity of the biomarker and makes the designed sensor specific for oval cells. The developed sensor can be easily embedded into the 3D-printed flow cell to allow cells to be exposed continuously to the functionalized surface. The continuous flow is intended to increase capture of most of the target cells in the specimen. Contact angle measurements were performed to characterize the nature and quality of the modified sensor surface, and electrochemical measurements (cyclic voltammetry (CV) and square wave voltammetry (SWV)) were performed to confirm the efficiency and selectivity of the fabricated sensor to detect HOCs. The proposed method is valuable for capturing rare cells and could provide an effective tool for cancer diagnosis and detection.
Read moreMonitoring cytochrome P450 activity in living hepatocytes by chromogenic substrates in response to drug treatment or during cell maturation.
The metabolic activity of hepatocytes is a central prerequisite for drug activity and a key element in drug-drug interaction. This central role in metabolism largely depends on the activity of the cytochrome P450 (CYP450) enzyme family, which is not only dependent on liver cell maturation but is also controlled in response to drug and chemical exposure. Here, we report the use of VividDye fluorogenic CYP450 substrates to directly measure and continuously monitor metabolic activity in living hepatocytes. We observed time- and dose-dependent correlation in response to established and putative CYP450 inducers acting through the aryl hydrocarbon receptor and drug combinations. Using repetitive addition of VividDye fluorogenic substrate on a daily basis, we demonstrated the new application of VividDye for monitoring the maturation and dedifferentiation of hepatic cells. Despite a lack of high specificity for individual CYP450 isoenzymes, our approach enables continuous monitoring of metabolic activity in living cells with no need to disrupt cultivation. Our assay can be integrated in in vitro liver-mimetic models for on-line monitoring and thus should enhance the reliability of these tissue model systems.
Read moreLiver-Kidney-on-Chip To Study Toxicity of Drug Metabolites.
Advances in organ-on-chip technologies for the application in in vitro drug development provide an attractive alternative approach to replace ethically controversial animal testing and to establish a basis for accelerated drug development. In recent years, various chip-based tissue culture systems have been developed, which are mostly optimized for cultivation of one single cell type or organoid structure and lack the representation of multi organ interactions. Here we present an optimized microfluidic chip design consisting of interconnected compartments, which provides the possibility to mimic the exchange between different organ specific cell types and enables to study interdependent cellular responses between organs and demonstrate that such tandem system can greatly improve the reproducibility and efficiency of toxicity studies. In a simplified liver-kidney-on-chip model, we showed that hepatic cells that grow in microfluidic conditions abundantly and stably expressed metabolism-related biomarkers. Moreover, we applied this system for investigating the biotransformation and toxicity of Aflatoxin B1 (AFB1) and Benzoalphapyrene (BαP), as well as the interaction with other chemicals. The results clearly demonstrate that the toxicity and metabolic response to drugs can be evaluated in a flow-dependent manner within our system, supporting the importance of advanced interconnected multiorgans in microfluidic devices for application in in vitro toxicity testing and as optimized tissue culture systems for in vitro drug screening.
Read moreA new droplet-forming fluidic junction for the generation of highly compartmentalised capsules.
A new oscillatory microfluidic junction is described, which enables the consistent formation of highly uniform and complex double emulsions, and is demonstrated for the encapsulation of four different reagents within the inner droplets (called cores) of the double emulsion droplets. Once the double emulsion droplets had attained a spherical form, the cores assumed specific 3D arrangements, the orchestration of which appeared to depend upon the specific emulsion morphology. Such double emulsion droplets were used as templates to produce highly compartmentalised microcapsules and multisomes. Based on these construct models, we numerically demonstrated a model chemical reaction sequence between and within the liquid cores. This work could provide a platform to perform space/time-dependent applications, such as programmed experiments, synthesis, and delivery systems.
Read moreCsr1/Zap1 Maintains Zinc Homeostasis and Influences Virulence in Candida dubliniensis but Is Not Coupled to Morphogenesis
The supply and intracellular homeostasis of trace metals are essential for every living organism. Therefore, the struggle for micronutrients between a pathogen and its host is an important determinant in the infection process. In this work, we focus on the acquisition of zinc by Candida dubliniensis, an emerging pathogen closely related to Candida albicans. We show that the transcription factor Csr1 is essential for C. dubliniensis to regulate zinc uptake mechanisms under zinc limitation: it governs the expression of the zinc transporter genes ZRT1, ZRT2, and ZRT3 and of the zincophore gene PRA1. Exclusively, artificial overexpression of ZRT2 partially rescued the growth defect of a csr1Δ/Δ mutant in a zinc-restricted environment. Importantly, we found that, in contrast to what is seen in C. albicans, Csr1 (also called Zap1) is not a major regulator of dimorphism in C. dubliniensis. However, although a csr1Δ/Δ strain showed normal germ tube formation, we detected a clear attenuation in virulence using an embryonated chicken egg infection model. We conclude that, unlike in C. albicans, Csr1 seems to be a virulence factor of C. dubliniensis that is not coupled to filamentation but is strongly linked to zinc acquisition during pathogenesis.
Read moreA newly designed optical biochip for a TDM-POCT device
The design of a novel therapeutic drug monitoring (TDM) point-of-care-testing (POCT) biochip for immunosuppressants detection in transplanted patients is described. The chip consists of two polymeric parts, a top PMMA slide and a bottom ZEONOR® thin foil, bonded together by means of a pressure sensitive adhesive tape. The tape, with lower refractive index, is shaped in order to obtain a microfluidic multi-channel array. The optical signal, coming from an external light source and travelling along the ZEONOR® thin foil, excites the fluorescent sensing layer immobilized onto the fluidic channels. Preliminary tests with the bioassay implementation for tacrolimus detection are reported.
Read moreChanging ligand number and type within nanocylindrical domains through kinetically constrained self-assembly - impacts of ligand 'redundancy' on human mesenchymal stem cell adhesion and morphology.