- Research Article
- 10.1016/j.measen.2024.101378
Estimation of force acting on oral cavity during swallowing using tongue simulator
- May 01, 2025
- Measurement: Sensors
- Shunsuke Ozawa + 2 more +2
Publications from 2021 to 2026
Showing 10 of 52 papers
Estimation of force acting on oral cavity during swallowing using tongue simulator
Design Guidelines for 2.5-D Packages Featuring Organic Interposer With Bridges Embedded
The rapid advancement of artificial intelligence (AI) has propelled the demand for high-performance computing (HPC) systems capable of handling vast amounts of data. This necessitates improvements in data processing speed within system-on-chip (SoC) units and efficient data transmission between SoC and high-bandwidth memory (HBM). Advanced packaging solutions, particularly the silicon interposer and organic interposer, have emerged to address these challenges. This article delves into the thermo-mechanical performance of 2.5-D packages with an organic interposer, focusing on warpage management during fabrication and stress analysis induced by coefficient of thermal expansion (CTE) mismatches. The study employs finite element analysis (FEA) modeling to evaluate the impact of various factors on warpage behavior and stress levels. Parametric studies on material selection and interposer geometric design reveal crucial insights. Specifically, reducing bridge die and redistribution layer (RDL) thickness mitigates warpage at the controlled collapse chip connection (C4) level, albeit with adverse effects on BGA level warpage. Material selection significantly influences warpage behavior. Organic materials with higher CTE reduce the mismatch between the interposer and the substrate but it is adverse for the interconnection between chiplets and interposer. Moreover, stress analysis indicates the organic interposer’s effectiveness in reducing interconnection stress compared to silicon interposers. This research contributes valuable insights into the design and optimization of advanced packages with bridges embedded in organic interposers, providing guidelines for material selection and geometric design to enhance reliability and functionality. The findings facilitate the development of advanced packaging solutions capable of meeting the demands of AI-driven applications in challenging operational environments.
Read moreRelationship Between Resultant Force Vector Acting on Human Organs From Food Bolus and the Bolus Configuration During Swallowing Using Numerical Swallowing Simulation With Moving Particle SimulationMethod.
This study investigates the forces exerted on organs during swallowing, specifically focusing on identifying forces other than those resulting from direct organ contact. Using a swallowing simulator based on the moving particle method, we simulated the swallowing process of healthy individuals upon the ingestion of thickened foods, which were simulated as shear-thinning flow without yield stress. We extracted the resultant force vectors acting on the organs and shape of the bolus at each time interval. The simulation results confirmed that the bolus originates from tongue movement and is transferred between the oral cavity and pharynx, with each organ's coordinated movements with the tongue occurring at their respective positions, as indicated by the balance of the resultant force vectors. Utilizing the information about the resultant force vectors obtained through simulations, we calculated the physical parameters of impulse, energy, and power. The variations in these physical parameters were aligned with the behaviors of both the biological system and the food bolus during swallowing. The force values calculated from the simulations closely approximate the theoretical values. Furthermore, the forces calculated from the simulations were relatively smaller than the force values derived from pressure information, such as that from high-resolution manometry and tongue pressure sensors. This difference can be attributed to the simulations extracting only the forces exerted on the organ by the food bolus. Force information on organs has the potential to provide a new interpretation of conventional mechanical indicators such as manometry and tongue pressure sensors.
Read moreAnisotropic expansion behavior and crack orientation of reinforced concrete due to the alkali–silica reaction
Barrier Factors of Adherence to Dupilumab Self-Injection for Severe Allergic Disease: A Non-Interventional Open-Label Study
PurposeThe status of dupilumab self-injection at home is not well understood. We therefore aimed to identify the barriers to adherence to dupilumab self-injection.Patients and MethodsThis non-interventional open-label study was conducted between March 2021 and July 2021. Patients with atopic dermatitis, bronchial asthma, and chronic rhinosinusitis with nasal polyps receiving dupilumab, from 15 sites, were requested to complete a self-administered questionnaire regarding the frequency and effectiveness of dosing as well as their use and satisfaction with dupilumab. Barriers to adherence were assessed using the Adherence Starts with Knowledge-12.ResultsWe included 331 patients who used dupilumab for atopic dermatitis (n = 164), chronic rhinosinusitis with nasal polyps (n = 102), and bronchial asthma (n = 65). The median efficacy of dupilumab scored 9.3 on the visual analog scale. Overall, 85.5% of the patients self-injected dupilumab, and 70.7% perfectly complied with the established injection dates. The pre-filled pen was significantly superior to the conventional syringe in terms of usability, operability, ease of pushing the plunger, and patient satisfaction. However, the pre-filled pen caused more pain during self-injection than did the syringe. Multivariate logistic regression analysis showed that adherence decreased with longer dupilumab treatment duration (p = 0.017) and was not associated with age, sex, underlying disease, or device type. There was a difference in responses related to “inconvenience/forgetfulness” between the good and poor adherence groups.ConclusionThe pre-filled dupilumab pen was superior to the syringe in terms of usability, operability, ease of pushing the plunger, and satisfaction. Repetitive instructions are recommended for preventing poor adherence to dupilumab self-injection.
Read moreLive Demonstration: An AI-assisted e-tongue for fast and portable fingerprinting of liquids
The design of cost-effective and rapid screening sensing systems is key to deliver alternative tools for chemical analysis. Electronic tongues can distinguish complex liquids by combining cross-sensitive sensor arrays with machine learning and have been demonstrated in various chemical sensing applications. In this live demonstration, feature extraction from the transient potentiometric response of an array of low-selective miniaturized polymeric sensors is combined with a data processing pipeline for deployment of trained machine learning models on an edge device. A mobile app allows visualization of raw data and measurement results in addition to reconfiguration of the device based on user selection.
Read moreTemperature Dependence of Current-Voltage Characteristics of Ionic Liquid Type Intelligent Connection Device
The temperature dependence of intelligent connection (IConnect) devices in which ionic liquid (IL) plays an important role in a memristive function is presented in this study. The appropriate choice of IL and dissolved metal ion species can control the volatility of IL-IConnect devices. The temperature dependence of IL-IConnect device was strong, although the change in the current-voltage characteristics was reversible in response to temperature variations. The device’s potential as a physical reservoir-computing device is studied. (Keywords: Ionic Liquids (IL), Intelligent Connection (IConnect) Device, IL-Reservoir device)
Read moreDevelopment of Materials Informatics Platform
As the use of IT increases importance with big data and AI, the issue of power consumption has been highlighted. Under these circumstances, the development of new materials is more and more important. Materials Informatics (MI) is one of the hottest technologies in the material development field, because of its potential to reduce the time and costs of discovering innovative materials. To achieve this, the key is to collect data that has been accumulated for many years at research institutions and companies, and to make information extracted from the data into knowledge. This article introduces the development of two methods based on AI: the “cognitive approach”, which reads vast amounts of literature information and digitizes data, and the “analytic approach”, which theoretically estimates the structure and physical properties of chemical substances from predictive models.
Read moreEffect of protective glasses on radiation dose to eye lenses during whole breast irradiation.
ObjectivesThe efficacy of radiotherapy for breast cancer has greatly improved owing to better irradiation methods. Radiotherapy aims to deliver therapeutic doses to predetermined target volumes while sparing surrounding healthy tissues. However, there are few reports on radiation exposure to eye lenses, and the recommended exposure limits to ocular lens have been substantially reduced in recent years. This study aimed to investigate the amount of radiation exposure to eye lenses using optically stimulated luminescence dosimeters (OSLDs) and determine whether wearing special protective devices to protect the eyes, as an organ at risk, during whole breast irradiation, is necessary.MethodsThis experiment used OSLDs on water‐equivalent phantom to measure the change in scattered radiation dose due to the difference of irradiation field while using 4‐ and 6‐MV photons of TrueBeam linear accelerator. Using a total treatment dose of 50 Gy, a target was positioned to approximate the breast, and a plan was formulated to deliver 2 Gy per treatment by tangential irradiation. The mean (SD) irradiation dose at the lens position outside the irradiation field was reported.ResultsThe scattered radiation dose outside the irradiation field was more affected by the irradiation field size than by the radiation energy. The out‐of‐field irradiation dose with a larger field of view was higher than that with a smaller field of view. The use of 0.07‐ and 0.83‐mm‐thick lead shield protective glasses reduced the radiation dose by 56.1% (P < .001) and 55.6% (P < .001), respectively.ConclusionsIn this experimental model, the amount of radiation the eye was exposed to during whole breast irradiation was determined by the distance of the eye from the radiation field edge and by wearing protective glasses. In clinical practice, the protection offered by eyeglasses may reduce the risk of long‐term side effects and allow the use of higher intensive radiotherapy.
Read moreMethanotroph (Methylococcus capsulatus, Bath) bacteria meal as an alternative protein source for Japanese yellowtail, Seriola quinqueradiata