- Research Article
- 10.1186/s12886-026-04740-w
Macular hole detection and segmentation on fundus photography using large multimodal generative models for synthetic augmentation.
- Mar 16, 2026
- BMC ophthalmology
- Tae Keun Yoo + 4 more +4
Publications from 2021 to 2026
Showing 10 of 116 papers
Macular hole detection and segmentation on fundus photography using large multimodal generative models for synthetic augmentation.
Artificial Intelligence’s Leap Toward Large-Scale Myopia Screening and the Challenges Ahead—A Vision of the Future
Correction to: Deep learning prediction of steep and flat corneal curvature using fundus photography in post‑COVID telemedicine era.
Intravitreal aflibercept 8 mg versus 2 mg in Asian patients with neovascular age-related macular degeneration: 48-week analysis of the Phase 3 PULSAR trial.
Early Clinical Experience with the Novel A-Stream Glaucoma Shunt Combined with Mid-Posterior Tenon's Capsule Advancement Flap.
Objectives: The aim of this study was to evaluate the clinical outcomes and surgical techniques of A-stream Glaucoma Shunt (A-stream; MICROT Inc.) implantation. Methods: A retrospective review of 59 eyes from 59 patients who underwent A-stream implantation was conducted. Eyes were divided into two groups: group A (25 eyes), where the distal tip of the ripcord was left exposed and the device was covered with conjunctiva, scleral flap, pericardium patch graft, or mid-posterior Tenon's capsule advancement flap (MPTAF); and group B (34 eyes), where the ripcord was shaped into a loop at the corneal limbus and the device was covered with MPTAF. Intraocular pressure (IOP), number of IOP-lowering medications, visual acuity, and postoperative complications were analyzed. Success was defined as an IOP ≤ 21 mmHg with ≥20% reduction from baseline, without clinically significant hypotony, and no reoperation for glaucoma. Results: At 6 months, the mean IOP decreased significantly in both groups (group A: 27.4 ± 9.8 mmHg to 15.2 ± 5.1 mmHg; group B: 25.1 ± 11.6 mmHg to 14.0 ± 7.0 mmHg, p < 0.001). Success rates were 76.0% in group A and 88.2% in group B (p = 0.207). Early postoperative hypotony occurred in 8.0% of group A and 14.7% of group B, and these cases resolved without further intervention within 1 month. Ripcord complications were observed in 28.0% of group A, but none in group B. Conclusions: A-stream implantation with MPTAF and a limbal ripcord loop is an effective and safe procedure with minimal risk of device exposure and ripcord-related complications.
Read moreRetinal Tears in Fundus-obscuring Vitreous Hemorrhages of Unknown Cause: Risk Factors and Surgical Outcomes
Purpose: To identify factors associated with retinal tears in eyes presenting with fundus-obscuring vitreous hemorrhage (FOVH) of unknown cause and to evaluate surgical findings and visual outcomes following pars plana vitrectomy (PPV).Methods: This retrospective study included patients who underwent 23-gauge or 25-gauge PPV for acute-onset FOVH, defined as a dense vitreous hemorrhage obscuring both the posterior pole and peripheral retina across at least three quadrants with a best-corrected visual acuity (BCVA) of counting fingers or worse at presentation.Etiologies of FOVH were identified intraoperatively, and subsequent analyses focused on the prevalence, clinical characteristics, and surgical outcomes of eyes diagnosed with retinal tears.Results: Among the 8 9 eyes in cluded, retinal tears were the most common etiology (38.2%), followed by retinal vascular occlusion (27.0%), and polypoidal choroidal vasculopathy (13.5%).Eyes with retinal tears were significantly younger (57.2 vs. 67.9years, p <0.001) and less likely to have diabetes (5.9 vs. 41.8%,p <0.001) compared with those without retinal tears.In a multivariate analysis, younger age (p < 0.001) and absence of diabetes (p = 0.007) were independent predictors of retinal tears.Among eyes with retinal tears, the mean duration from symptom onset to surgery was 9.2 days.Most eyes (67.6%) had a single tear, and in 79.4%, the largest tear was in the superior quadrant.No cases of macular-off retinal detachment or proliferative vitreoretinopathy were observed.At final follow-up, 82.4% of the eyes achieved a BCVA of 20/20, with no cases of reoperation.Conclusions: Retinal tears are commonly identified intraoperatively in eyes presenting with FOVH, with younger age and absence of diabetes significantly associated with their presence.Despite delayed surgery, favorable anatomical and visual outcomes were achieved.Given the frequent localization of tears in the superior retina, careful peripheral inspection during vitrectomy is essential for detecting treatable pathology.
Read moreEvaluating ChatGPT-4o for ophthalmic image interpretation: From in-context learning to code-free clinical tool generation
Background: Large language models (LLMs) such as ChatGPT-4o have demonstrated emerging capabilities in medical reasoning and image interpretation. However, their diagnostic applicability in ophthalmology, particularly across diverse imaging modalities, remains insufficiently characterized. This study evaluates ChatGPT-4o’s performance in ophthalmic image interpretation, exemplar-guided reasoning (in-context learning), and code-free diagnostic tool generation using publicly available datasets. Methods: We assessed ChatGPT-4o through three clinically relevant tasks: (1) image interpretation without prior examples, using fundus, external ocular, and facial photographs representing key ophthalmic conditions; (2) in-context learning with example-based prompts to improve classification accuracy; and (3) generation of an interactive HTML-based decision-support tool from a clinical diagnostic algorithm. All evaluations were performed using open-access datasets without model fine-tuning Results: When interpreting images without reference examples, ChatGPT-4o achieved diagnostic accuracies of 90.3 % for diabetic retinopathy, 77.4 % for age-related macular degeneration, 100 % for conjunctival melanoma, 97.3 % for pterygium, and 85.7 % for strabismus subtypes. In-context learning consistently improved diagnostic performance across all modalities, with strabismus classification reaching 100 % accuracy. Compared to EfficientNetB2, ChatGPT-4o demonstrated comparable or superior performance in several diagnostic tasks. Additionally, the model successfully translated schematic clinical algorithms into functional, browser-based diagnostic tools using natural language prompts alone. Conclusions: ChatGPT-4o demonstrates promise in ophthalmic image interpretation and low-code clinical tool development, particularly when guided by in-context learning. However, these findings are based on a limited diagnostic spectrum and publicly available datasets. Broader clinical validation and head-to-head comparisons with domain-specific models are needed to establish its practical utility in ophthalmology.
Read moreComparison of Persistent Postoperative Discomfort 1 Year after Keratorefractive Lenticule Extraction and Implantable Collamer Lens Implantation
PurposeTo compare the prevalence and characteristics of persistent postoperative discomfort 1 year after keratorefractive lenticule extraction (KLEX) and implantable collamer lens (ICL) implantation.MethodsThis retrospective comparative study included 324 eyes from 324 patients with myopia or myopic astigmatism who underwent bilateral KLEX (n = 227) or ICL implantation (n = 97) at a single center. One year postoperatively, visual outcomes, patient satisfaction, and persistent discomfort symptoms were evaluated using a standardized questionnaire, including symptom frequency, severity, and resolution time.ResultsVisual outcomes and overall satisfaction were high and comparable between the two groups (97.3% for KLEX vs. 99.0% for ICL; p = 0.157). Persistent glare and halos were significantly less frequent in the KLEX group than in the ICL group (glare: 50.2% vs. 64.9%, p = 0.045; halos: 48.9% vs. 63.9%, p = 0.034). The time to resolution for these symptoms was significantly shorter in the KLEX group (p = 0.031 and p = 0.024, respectively). In contrast, dryness was more frequent, severe, and bothersome in the KLEX group than in the ICL group (all p < 0.001), and its resolution time was longer (p = 0.008).ConclusionsKLEX and ICL implantation showed distinct profiles of persistent postoperative discomfort at 1 year. ICL implantation was associated with higher rates and longer duration of glare and halos, while KLEX was associated with more severe and persistent dryness. These findings underscore the importance of individualized preoperative counseling and patient selection.
Read moreComparative Outcomes of the Next-Generation Extended Depth-of-Focus Intraocular Lens and Enhanced Monofocal Intraocular Lens in Cataract Surgery
Background/Objectives: A new, purely refractive extended depth-of-focus (EDOF) intraocular lens (IOL) was designed with a continuous change in power to bridge the gap between monofocal and multifocal IOLs. This study aimed to evaluate the real-world clinical outcomes of the new EDOF IOL compared with those of the enhanced monofocal IOL. Methods: A retrospective analysis was conducted on 100 eyes from 50 patients undergoing bilateral cataract surgery with either the PureSee™ EDOF (ZEN00V) or Eyhance™ (ICB00) monofocal IOL at a single institution. Visual acuity, defocus curves, contrast sensitivity, and patient-reported outcomes were evaluated three months postoperatively. Results: The ZEN00V group demonstrated superior uncorrected intermediate (0.11 ± 0.08 vs. 0.17 ± 0.11 logMAR, p = 0.006) and near visual acuity (0.25 ± 0.08 vs. 0.31 ± 0.13 logMAR, p = 0.023) compared to the ICB00 group, with comparable distance visual acuity. Both groups exhibited comparable defocus curves and contrast sensitivity. While photic phenomena were more frequent in the ZEN00V group, spectacle dependence was significantly lower for near vision (36% vs. 80%, p = 0.002) and comparable for intermediate and far vision. Conclusions: The PureSee™ EDOF IOL demonstrated enhanced intermediate and near vision with minimal compromise to distance vision while maintaining high contrast sensitivity. It also offered significant spectacle independence and patient satisfaction, making it a promising option for presbyopia correction.
Read moreControversies, consensuses and guidelines on posterior chamber phakic intraocular lens for the correction of myopia and myopic astigmatism in healthy phakic eyes by the Academy of Asia-Pacific Professors of Ophthalmology (AAPPO) and the Asia-Pacific Myopia Society (APMS).