- Research Article
- 10.1016/j.jocmr.2026.102708
Ultrafast deep learning super-resolution single-shot T2-weighted imaging for robust edema visualization in cardiovascular magnetic resonance.
- Mar 07, 2026
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
- Taraneh Aziz-Safaie + 12 more +12
To compare the diagnostic quality of deep learning (DL) super-resolution reconstructed breath-hold (BH) and free-breathing (FB) single-shot (SSH) black-blood T2-weighted short tau inversion recovery (STIR) imaging with standard BH T2-STIR in cardiovascular magnetic resonance (CMR). In this prospective study, short-axis BH and FB SSH T2-STIR were added to a standard cardiomyopathy CMR protocol at 1.5T, and DL super-resolution reconstruction was performed. Two readers evaluated diagnostic quality and certainty using a five-point Likert scale. Presence of focal edema was assessed on T2-weighted sequences, including standard T2-STIR and T2 mapping (both used for reference clinical assessment) as well as SSH T2 STIR and DL-SSH T2-STIR. Friedman test and one-way ANOVA were performed. Eighty-one participants (mean age: 54 ±20 years; 50 men) were included. No difference was found in edema detection between reference assessment and DL-SSH T2-STIR (both 26%, (21/81 participants)). Scan time was reduced by 63% for BH and 86% for FB DL-SSH T2-STIR compared to standard T2-STIR (90± 6s vs. 35± 3s vs. 243± 16s; p<.0001). BH and FB DL-SSH T2-STIR achieved lower artifact burden (5 [IQR, 4-5] vs. 4 [IQR, 4-5] vs. 4 [IQR, 3-5]; p<.0001), superior image contrast and sharpness compared to standard T2-STIR, especially in non-cooperative or arrhythmic participants. BH and FB DL-SSH T2-STIR imaging provided higher diagnostic certainty than standard T2-STIR (5 [IQR, 5-5] vs. 5 [IQR, 5-5] vs. 4 [IQR, 4-5]; p<.0001). Edema visibility was superior in BH DL-SSH compared to BH-SSH and standard T2-STIR (5 [IQR, 4.8-5] vs. 4 [IQR, 3.3-5] vs. 4 [IQR, 3-4.8]; p<.0001). Inter-rater agreement was substantial to excellent in the rating of edema visibility (BH DL-SSH T2-STIR, κ: 0.73 [95% CI: 0.44-1.0]; BH SSH T2-STIR, κ: 0.79 [95% CI: 0.66-0.97]; standard T2-STIR, κ: 0.86 [95% CI: 0.71-1.0]). Slice level-analysis showed that BH DL-SSH T2-STIR consistently provided superior image quality in apical slices compared to BH SSH and standard T2-STIR (4 [IQR, 4-5] vs. 4 [IQR, 4-4] vs. 4 [IQR, 3-4]; p<.0001). DL-SSH imaging enabled ultrafast T2-STIR acquisition and robust edema assessment in routine clinical CMR.
Read more