- Conference Article
- 10.1063/12.0042931
Coal bed methane decarbonization via CO2 capture and storage and blue methane production
- Jan 01, 2026
- AIP conference proceedings
- Clodic Denis + 1 more +1
Publications from 2021 to 2026
Showing 10 of 37 papers
Coal bed methane decarbonization via CO2 capture and storage and blue methane production
3D Compressible Flow Analysis of an Ultra-High-Head Pumped Storage Unit with Water Conveyance System at Maximum Pumping Head
Severe pressure pulsations caused by complex flow fields in pumped-storage power stations significantly threaten operational safety and stability. With advances in computational technology, fully three-dimensional simulations coupling pipelines and pump-turbine units have become feasible. In this study, a fully three-dimensional analysis model was developed, coupling the water conveyance system and a finely modeled prototype-scale pump-turbine with splitter blades, to numerically simulate the compressible flow field under the maximum head pump mode. The study reveals a strong bidirectional coupling between the flow in the long outlet pipe and the internal flow within the pump-turbine unit. Influenced by structural features such as bifurcations and flow impingement at the T-junction, complex three-dimensional vortices arise and cannot be neglected. Based on the flow field, the study further investigates the time-domain, frequency-domain, and spatial characteristics of pressure pulsations at various downstream hydraulic components, ranging from the vaneless space to the outlet of the long outlet pipe. The pressure pulsation frequencies are shown to be affected by both rotor–stator interactions and the complex vortical structures in the flow. These findings clearly demonstrate the necessity of fully three-dimensional simulations that incorporate both the water conveyance system and the pump-turbine unit.
Read moreFluid–Structure Interactions in Pump-Turbines: A Comprehensive Review
With the global transition towards renewable energy, pumped storage has become a pivotal technology for large-scale energy storage, playing an essential role in peak load regulation, frequency control, and ensuring the stability of modern power systems. As the core equipment of pumped storage power stations, pump-turbines operate under complex and frequently changing conditions. These units are required to switch repeatedly between pumping, generating, and transitional modes, giving rise to significant fluid–structure interactions (FSIs). Such interactions have a profound impact on the operational performance and stability of the units. This review provides a comprehensive summary of current research on FSIs in pump-turbines, encompassing both experimental investigations and numerical simulations. Key topics discussed include internal flow dynamics, vibration and acoustic characteristics, and structural responses such as runner deformation and stress distribution. Various numerical coupling strategies for FSI modeling are also examined in detail. Despite progress in this field, several challenges remain, including the complexity of multidisciplinary coupling, the difficulty in developing and solving accurate models, and limitations in predictive capabilities. This review highlights the critical requirements for advancing FSI research in pump-turbines and identifies gaps in the current literature that warrant further investigation.
Read moreHydro-vibration resonance analysis of ultra high head pump turbine submerged in water
The stability and safety of the pump turbine runner are crucial to the long-term operation of pumped storage power stations. Strong pressure pulsations caused by stator rotor interaction (SRI) can lead to strong vibrations or even resonance of the pump turbine runner, especially with ultra-high heads, which can cause severe structural fatigue damage. Therefore, it becomes particularly important to investigate the modal behavior and hydro-vibration resonance of the pump turbine runners at the design stage. In this paper, the modal behavior analysis of a 300MW pump turbine with a maximum head of 500m is carried out the modal behavior analysis considering the effects of the near-wall boundary, small gaps of the labyrinth seals, and the water added mass of the pump turbine runner. The results show that the critical vibration mode of the runner is the 4 node diameters (ND), and the difference between the natural frequency for 4 ND and the SRI induced pressure excitation frequency is only about 2%. Therefore, the runner will be subjected to strong vibration as it is almost in a hydrodynamic vibration resonance state. The countermeasures are provided to redesign the runner and change the number of guide vanes so that the hydro-vibration resonance can be avoided. The research methodology can be used for the optimal design of pump turbines, turbines, and pumps of other power stations and pumping stations.
Read moreAlpha-particle confinement in Infinity Two Fusion Pilot Plant baseline plasma design
In this work, we present a detailed assessment of fusion-born alpha-particle confinement, their wall loads and stability of Alfvén eigenmodes driven by these energetic particles in the Infinity Two Fusion Pilot Plant baseline plasma design, a four-field-period quasi-isodynamic stellarator to operate in deuterium–tritium fusion conditions. Using the Monte Carlo codes, SIMPLE, ASCOT5 and KORC-T, we study the collisionless and collisional dynamics of guiding-centre and full-orbit alpha-particles in the core plasma. We find that core energy losses to the wall are less than 4 %. Our simulations shows that peak power loads on the wall of this configuration are approximately 2.5 MW m- $^2$ and are spatially localised, toroidally and poloidaly, in the vicinity of x-points of the magnetic island chain $n/m = 4/5$ outside the plasma volume. Also, an exploratory analysis using various simplified walls shows that shaping and distance of the wall from the plasma volume can help reduce peak power loads. Our stability assessment of Alfvén eigenmodes using the STELLGAP and FAR3d codes shows the absence of unstable modes driven by alpha-particles in Infinity Two due to the relatively low alpha-particle beta at the envisioned 800 MW operating scenario.
Read moreMagnetohydrodynamic equilibrium and stability properties of the Infinity Two fusion pilot plant
The magnetohydrodynamic (MHD) equilibrium and stability properties of the Infinity Two fusion pilot plant baseline plasma physics design are presented. The configuration is a four-field period, aspect ratio $A = 10$ quasi-isodynamic stellarator optimised for excellent confinement at elevated density and high magnetic field $B = 9\,T$ . Magnetic surfaces exist in the plasma core in vacuum and retain good equilibrium surface integrity from vacuum to an operational $\beta = 1.6 \,\%$ , the ratio of the volume average of the plasma and magnetic pressures, corresponding to $800\ \textrm{MW}$ deuterium–tritium fusion operation. Neoclassical calculations show that a self-consistent bootstrap current of the order of ${\sim} 1\ \textrm{kA}$ slightly increases the rotational transform profile by less than 0.001. The configuration has a magnetic well across its entire radius. From vacuum to the operating point, the configuration exhibits good ballooning stability characteristics, exhibits good Mercier stability across most of its minor radius and it is stable against global low-n MHD instabilities up to $\beta = 3.2\,\%$ .
Read moreValleys Low, Mountains High: Embedding the 2003 Convention in Switzerland
Abstract From a cultural-political perspective, the UNESCO Convention for the Safeguarding of the Intangible Cultural Heritage is a global winner. It is one of the most successful international agreements in the field of culture. Nonetheless, the authors believe that this convention—at least in Switzerland—is often undervalued in the cultural policy arena and, in particular, is still not applied adequately. As a result, the strengths and dynamics coming from the convention’s fundamentally bottom-up approach remain largely untapped. In their analysis, the authors will refer to various key decisions made in the past regarding implementation of the convention in Switzerland. There will be particular emphasis on the formation of the inventory and UNESCO applications, the inclusion of tradition bearers as well as measures taken to safeguard intangible cultural heritage.
Read moreInsights from Subsurface Monitoring for Engineering of the Stimulation Pattern in Fractured Reservoirs
Abstract Stimulation operations enhance the performance of geothermal reservoirs by boosting fluid flow and heat transfer. Predicting stimulation outcomes is challenging due to complexity of reservoir properties and limited observations given by operational conditions. Factors like stress state, natural structures, pressure distribution, and injection patterns play crucial roles in engineering of a stimulation operation. This study provides in-depth observations from a hectometer-scale stimulation experiment conducted at the Bedretto Underground Laboratory for Geosciences and Geoenergies within a densely monitored crystalline rock volume with an overburden of more than 1 km. We found that hydraulic connectivity, pressure compartments, and the characteristics of existing geological structures play pivotal roles in the propagation patterns of seismic events. Notably, the initiation and distribution of seismicity are markedly influenced by the zonal isolation and the structured propagation of pressure front across the reservoir. The research highlights the necessity of adapting stimulation strategies to the unique geomechanical as well as geological characteristics of the reservoir, as evident from the distinct activation patterns observed between the first and second injection cycles. The spatial extent of the stimulated volume can be partially guided by the number of stimulation cycles and injection pressure level, as farther structures are increasingly likely to be activated in the subsequent cycles. The results also indicate that the Kaiser effect is more pronounced in regions closer to the injection borehole. However, this effect can be attenuated due to stress changes caused by stimulation, consistent with a proposition from a recent study. Our findings underscore the critical importance of understanding the interplay between hydraulic pressures and stress states to optimize the stimulation of geothermal reservoirs effectively.
Read moreWhat drives electricity tariffs in Switzerland? Two-stage statistical and geospatial analysis of structural differences across 1913 municipalities
HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L'archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d'enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.
Read moreNumerical Study on the Flow and Structural Characteristics of a Large High Head Prototype Pump-Turbine under Different Operating Conditions
During the operation of pumped storage power stations, complex operating conditions can lead to different internal flow characteristics, which can cause different vibration characteristics or even damage to the structural components of the pump-turbine units. The time–frequency characteristics of the structural components’ response are of great significance for the safe operation of the unit. In this study, a three-dimensional flow field and structural field model of a large high head prototype pump-turbine is built in order to study the flow and the flow-induced dynamic response characteristics in different turbine operating conditions. The analyzed results show that the maximum deformation occurs at the inner head cover, and the maximum value of stress is located at the fillets on the outlet side of the stay vanes. Under the 50% load condition, the vortices in the runner caused by changes in the opening of the guide vanes result in the main response frequency of 4 fn of the stationary components. The research results can provide references for the structural optimization design of other pump-turbine units.
Read more