- Research Article
- 10.1016/j.oret.2024.06.012
Supplemental Intravitreal Ranibizumab Injections in Eyes Treated with the Port Delivery System with Ranibizumab in the Archway Trial
- Jun 22, 2024
- Ophthalmology Retina
- Jared S Nielsen + 9 more +9
Publications from 2021 to 2026
Showing 10 of 19 papers
Supplemental Intravitreal Ranibizumab Injections in Eyes Treated with the Port Delivery System with Ranibizumab in the Archway Trial
Clinical Outcomes of a Non-Diffractive Extended Depth-of-Focus IOL in Eyes with Mild Glaucoma
PurposeTo evaluate the clinical outcomes of a non-diffractive, wavefront-shaping extended depth-of-focus (EDOF) intraocular lens (IOL) in eyes with mild open-angle glaucoma (OAG).SettingPrivate practice; Sioux Falls, South Dakota.DesignProspective, open-label, interventional study.MethodsIn total, 52 eyes of 26 patients with mild OAG were enrolled and completed the study. All patients were bilaterally implanted with a non-diffractive, wavefront-shaping EDOF IOL. Seventy-seven percent of the patients were implanted with a trabecular microbypass stent at the time of surgery. Primary outcome measures included binocular corrected and uncorrected distance visual acuity (CDVA and UDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA) and contrast sensitivity as measured by a Pelli-Robson chart. A subjective questionnaire was also administered to patients.ResultsAt 4 months postoperative, the mean binocular UDVA and CDVA was 0.03 ± 0.12 and −0.06 ± 0.07, respectively. The mean UIVA and UNVA were 0.18 ± 0.12 and 0.31 ± 0.18, respectively. Eighty-five percent of the subjects achieved ≥20/25 UDVA and 77% of the subjects achieved ≥20/32 UIVA at 4 months postoperative. The mean binocular mesopic contrast sensitivity was 1.76 ± 0.16 at a spatial frequency of 1 cycle-per-degree (cpd). Eighty-five percent of the subjects reported they would choose the same lens and 1 subject reported they would choose a different IOL if it meant reduced spectacle independence.ConclusionThe non-diffractive, wavefront-shaping EDOF IOL can be safely implanted in eyes with mild, pre-perimetric open-angle glaucoma with favorable uncorrected distance and intermediate visual acuity. The contrast sensitivity measurements were favorable and the subjective questionnaire revealed satisfactory spectacle independence and patient satisfaction.
Read morePCR144 Mosaic: A Qualitative Study of the Humanistic and Financial Burden on Unpaid Caregivers of Patients with Geographic Atrophy (GA)
Trends in horizontal periocular asymmetry
Patient-, Caregiver-, and Eye Care Professional-reported Burden of Geographic Atrophy Secondary to Age-related Macular Degeneration
Objective Geographic atrophy (GA) is a progressive, irreversible advanced form of age-related macular degeneration. There is limited information on the burden of illness of GA from patient, caregiver, and eye care professional perspectives. This study identifies key factors that should be included for assessment in future studies of patients with GA. Methods In this cross-sectional qualitative study, patients with symptomatic GA (n = 8), their caregivers (n = 6), and eye care professionals who treat patients with GA (n = 5) were interviewed at US sites. Interview guides were designed to evaluate the understanding of the disease, costs and burden of illness, use of vision aids or services, and impact on emotional or psychological well-being and on daily activities. Results Half of the patients mentioned social, psychological, or helplessness issues. Patients reported the impact of GA on sports and outdoor hobbies, meals or food preparation, religious activities, and long-distance travel. Patients reported having stopped driving or changing driving patterns as a major concern. 38% of all patients reported previously modifying their work schedules due to vision impairment. All patients reported the use of at least one vision aid, with 88% of patients purchasing the aids out of pocket. Caregivers reported modifying their schedules to provide assistance as needed and expressed frustration over their inability to improve patients’ health. Eye care professionals noted the emotional impact of vision loss, accidents, and injuries, and identified mental health as a key topic for patients with GA. Conclusions Although limited by size, this study indicates that GA has a major negative impact on patients’ and caregivers’ social functioning and health-related quality of life. This study has identified indirect resource use, including caregiving needs, and direct patient out-of-pocket costs as factors relevant to patients with GA. Future larger studies are needed to further characterize the burden of illness of GA for patients and caregivers.
Read moreHome tonometry in childhood glaucoma: clinical indications and physician and parental attitudes
Preoperative measurement vs intraoperative aberrometry for the selection of intraocular lens sphere power in normal eyes
PurposeThis study aimed to assess the value of intraoperative aberrometry (IA) in determining the intraocular lens (IOL) sphere power in eyes with no previous ocular surgery.Patients and methodsWe conducted a retrospective review of patients who underwent uncomplicated cataract surgery where standard preoperative (Preop) measurements and IA were performed. Calculated IOL sphere powers and postoperative refractions, both actual and theoretical, were compared based on the measurement method and lens type; lens types included multifocal, toric and aspheric single-vision non-toric IOLs.ResultsA total of 160 eyes of 112 patients were analyzed. The Preop lens power calculated was the same as the IA lens power 46% of the time, though this percentage was lower for multifocal IOLs. Across all lens types, there was a statistically significant bias (chi-square test, P<0.01) toward the IA method suggesting a lower powered lens. Actual postoperative refractive errors were not statistically significantly different when categorized by measurement method. Calculated errors by measurement method showed no statistically significant differences in expected outcomes. There were 63 cases where the Preop calculation and the intraoperative aberrometer calculation differed by 0.5 D. In 56% (35/63) of these cases, the IA result was a better option, and in 44% (28/63) of cases, the Preop calculation was better; this was not statistically significantly different from random expectation (50/50, P=0.53). In the three cases where calculated powers differed by 1.5 D, there appeared to be a positive effect of adjusting the Preop power toward the IA power.ConclusionThe use of IA for the determination of sphere power in eyes with no previous ocular surgery does not appear to improve overall expected clinical outcomes, but it may be helpful in cases where the difference between IA and Preop calculations is high.
Read moreAssessing the Effect of Personalized Diabetes Risk Assessments During Ophthalmologic Visits on Glycemic Control: A Randomized Clinical Trial.
Optimization of glycemic control is critical to reduce the number of diabetes mellitus-related complications, but long-term success is challenging. Although vision loss is among the greatest fears of individuals with diabetes, comprehensive personalized diabetes education and risk assessments are not consistently used in ophthalmologic settings. To determine whether the point-of-care measurement of hemoglobin A(1c) (HbA(1c)) and personalized diabetes risk assessments performed during retinal ophthalmologic visits improve glycemic control as assessed by HbA(1c) level. Ophthalmologist office-based randomized, multicenter clinical trial in which investigators from 42 sites were randomly assigned to provide either a study-prescribed augmented diabetes assessment and education or the usual care. Adults with type 1 or 2 diabetes enrolled into 2 cohorts: those with a more-frequent-than-annual follow-up (502 control participants and 488 intervention participants) and those with an annual follow-up (368 control participants and 388 intervention participants). Enrollment was from April 2011 through January 2013. Point-of-care measurements of HbA1c, blood pressure, and retinopathy severity; an individualized estimate of the risk of retinopathy progression derived from the findings from ophthalmologic visits; structured comparison and review of past and current clinical findings; and structured education with immediate assessment and feedback regarding participant's understanding. These interventions were performed at enrollment and at routine ophthalmic follow-up visits scheduled at least 12 weeks apart. Mean change in HbA(1c) level from baseline to 1-year follow-up. Secondary outcomes included body mass index, blood pressure, and responses to diabetes self-management practices and attitudes surveys. In the cohort with more-frequent-than-annual follow-ups, the mean (SD) change in HbA(1c) level at 1 year was -0.1% (1.5%) in the control group and -0.3% (1.4%) in the intervention group (adjusted mean difference, -0.09% [95% CI, -0.29% to 0.12%]; P = .35). In the cohort with annual follow-ups, the mean (SD) change in HbA(1c) level was 0.0% (1.1%) in the control group and -0.1% (1.6%) in the intervention group (mean difference, -0.05% [95% CI, -0.27% to 0.18%]; P = .63). Results were similar for all secondary outcomes. Long-term optimization of glycemic control is not achieved by a majority of individuals with diabetes. The addition of personalized education and risk assessment during retinal ophthalmologic visits did not result in a reduction in HbA(1c) level compared with usual care over 1 year. These data suggest that optimizing glycemic control remains a substantive challenge requiring interventional paradigms other than those examined in our study. clinicaltrials.gov Identifier:NCT01323348.
Read moreMultimodal imaging of white and dark without pressure fundus lesions.
To describe multimodal imaging findings in patients with dark or white without pressure lesions of the fundus. Retrospective observational case series of 10 patients with white or dark without pressure lesions. We analyzed multimodal imaging using spectral domain optical coherence tomography, color and near-infrared fundus photography, and fundus autofluorescence imaging to explore the findings associated with these lesions. All patients had geographic dark or white lesions on clinical examination and color photography, which were either hyporeflective or hyperreflective on near-infrared reflectance imaging, respectively. On optical coherence tomography, these lesions correlated with an abrupt change of the photoreceptor reflectivity, with relative hyporeflectivity of photoreceptor zones (ellipsoid and interdigitation zones, as well as outer segments) within the dark, and relative hyperreflectivity within white lesions. Ten patients underwent fundus autofluorescence, which showed well-defined zones of relative hypo-autofluorescence within the lesion, compared with neighboring uninvolved regions, whether dark or white without pressure. In two patients who had a lesion combining white and dark without pressure, we observed the transition in photoreceptor reflectivity from the dark lesion (hyporeflective) to the white lesion (hyperreflective), relative to the surrounding retina. Both white and dark without pressure lesions are associated with changes in outer retinal reflectivity on optical coherence tomography, which occur in opposite directions compared with the surrounding unaffected areas. In the face of normal visual field testing to date, the clinical significance of this finding remains uncertain. Recognition of the optical coherence tomography appearance will help clinicians avoid unnecessary workup of these patients for outer retinal dystrophy or degeneration.
Read moreRIFAMPIN INDUCED HEPATOTOXICITY DURING TREATMENT FOR CHRONIC CENTRAL SEROUS CHORIORETINOPATHY
The purpose of this report is to present a case of hepatotoxicity secondary to off-label rifampin therapy for the treatment of chronic central serous choroidopathy. Case report. A patient with chronic central serous chorioretinopathy was treated with oral rifampin. Three weeks after the initiation of therapy, fatigue, nausea, and malaise associated with elevated liver enzyme elevations were noted. Symptoms resolved and liver enzymes normalized after discontinuing rifampin. Rifampin-induced hepatic injury can occur during therapy for chronic central serous chorioretinopathy. Potential hepatotoxicity must be considered and followed closely during off-label rifampin treatment.
Read more