Abstract

Slab-selective radiofrequency (RF) pulses are commonly required in three-dimensional (3D) turbo spin echo (TSE) in brachial plexus magnetic resonance neurography (MRN). However, their long selective RF pulses lead to violation of Carr-Purcell-Meiboom-Gill conditions, which might increase imaging artifacts. That VERSE STIR-TSE would yield comparable motion artifact to conventional STIR-TSE with superior nerve conspicuity and greater subjective appeal. Prospective, cross-sectional study. Twenty-four subjects (16 females; mean age: 43.7 years; range: 19-76 years) evaluated for clinical suspicion of brachial plexopathy, undergoing brachial plexus MRI (10 left, 9 right, 5 bilateral, 29 total scans analyzed). Agar phantoms mimicking nerve and muscle were also evaluated. 3-Tesla, 3D STIR-TSE with and without VERSE. Three radiologists, blinded to the sequence type and clinical data, qualitatively evaluated nerve conspicuity, motion, and preferred sequence on a 5-point scale. Wilcoxon signed-rank tests compared nerve conspicuity (0-4 scale), motion artifact (0-4 scale), and preferred series between the non-VERSE and VERSE pulse sequences. Gwet's AC2 assessed inter-rater agreement. A p-value < 0.05 was considered statistically significant. The VERSE STIR-TSE sequence was significantly preferred by all raters. Motion artifact was not significantly different between the sequences (p = 0.11). Conspicuity of the suprascapular nerve was significantly greater with VERSE for both its proximal segments (median: 3, interquartile range: (2, 4), vs. 3 (1, 4)) and distal segments (4 (2, 4) vs. 3 (2, 4)), but conspicuity of the axillary nerve was not significantly different between the sequences (p = 0.27-0.61). Phantom scans confirmed a 74% and 49% increase in signal with VERSE in the muscle and nerve-mimicking phantoms, respectively. STIR-TSE with VERSE provided overall superior image quality for brachial plexus MRN as compared to conventional STIR-TSE. 2. 1.

Similar Papers
  • Research Article
  • Citations109

Thoracic outlet syndrome in 3T MR neurography—fibrous bands causing discernible lesions of the lower brachial plexus

  • Nov 22, 2013
  • European Radiology
  • P Baumer +6
  • Research Article
  • Citations17

New spatial localization method using pulsed high‐order field gradients (SHOT: Selection with high‐order gradient)

  • Mar 01, 1991
  • Magnetic Resonance in Medicine
  • C H Oh +3
  • PDF
  • Research Article
  • Citations58

Functional Magnetic Resonance Imaging in Conscious Animals: A New Tool in Behavioural Neuroscience Research

  • Mar 28, 2006
  • Journal of Neuroendocrinology
  • Cf Ferris +8
  • Research Article
  • Citations10

B0‐informed variable density trajectory design for enhanced correction of off‐resonance effects in parallel transmission

  • May 28, 2013
  • Magnetic Resonance in Medicine
  • Rainer Schneider +3
  • Research Article
  • Citations81

MR Neurography of Brachial Plexus at 3.0 T with Robust Fat and Blood Suppression.

  • Dec 22, 2016
  • Radiology
  • Xinzeng Wang +6
  • Conference Article

3D-imaging of the Liver by Free-Breath SPACE with a 3.0T MRI system

  • May 01, 2007
  • T Moroi +6
  • Research Article
  • Citations24

Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging

  • Jun 04, 2012
  • Magnetic Resonance Imaging
  • Eleftherios Lavdas +7
  • Research Article
  • Citations11

Combined T2 -preparation and two-dimensional pencil-beam inner volume selection.

  • Aug 27, 2014
  • Magnetic resonance in medicine
  • Andrew J Coristine +2
  • Research Article
  • Citations170

Selective Saturation NMR Imaging

  • Oct 01, 1984
  • Journal of Computer Assisted Tomography
  • B R Rosen +2
  • Research Article
  • Citations17

Somatotopic Fascicular Lesions of the Brachial Plexus Demonstrated by High-Resolution Magnetic Resonance Neurography.

  • Dec 01, 2017
  • Investigative Radiology
  • Tim Hilgenfeld +7
  • Research Article
  • Citations17

Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo.

  • Jan 29, 2018
  • Magnetic Resonance in Medicine
  • Barbara Cervantes +8
  • Research Article
  • Citations17

Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses.

  • Jun 23, 2010
  • Journal of magnetic resonance imaging : JMRI
  • Jing Yuan +3
  • Research Article
  • Citations34

SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences

  • Aug 04, 2012
  • European Radiology
  • Joon-Yong Jung +4
  • Research Article
  • Citations28

High-resolution 3T MR Neurography of Suprascapular Neuropathy

  • May 04, 2011
  • Academic Radiology
  • Majid Chalian +7
  • Research Article
  • Citations17

Functional adaptation of venous smooth muscle response to vasoconstriction in proximal, distal, and varix segments of varicose veins

  • Mar 27, 2010
  • Journal of Vascular Surgery
  • Joseph D Raffetto +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.