• Home
  • Search
  • Combined T2 -preparation and two-dimensional pencil-beam inner volume selection.
  • Cite Icon11
  • https://doi.org/10.1002/mrm.25442Copy DOI Icon

Combined T2 -preparation and two-dimensional pencil-beam inner volume selection.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.

Similar Papers
  • PDF
  • Research Article
  • Citations58

Functional Magnetic Resonance Imaging in Conscious Animals: A New Tool in Behavioural Neuroscience Research

  • Mar 28, 2006
  • Journal of Neuroendocrinology
  • Cf Ferris +8
  • Research Article
  • Citations10

B0‐informed variable density trajectory design for enhanced correction of off‐resonance effects in parallel transmission

  • May 28, 2013
  • Magnetic Resonance in Medicine
  • Rainer Schneider +3
  • Research Article
  • Citations1

Multidimensional RF pulse design using auto-differentiable spin-domain optimization and its application to reduced field-of-view imaging.

  • Jun 16, 2025
  • Magnetic resonance in medicine
  • Jiayao Yang +3
  • Research Article
  • Citations42

Designing adiabatic radio frequency pulses using the Shinnar–Le Roux algorithm

  • Aug 25, 2010
  • Magnetic Resonance in Medicine
  • Priti Balchandani +2
  • Research Article
  • Citations2

Usefulness of compressed sensing coronary magnetic resonance angiography with deep learning reconstruction

  • Jan 01, 2025
  • Japanese Journal of Radiology
  • Kohei Tabo +8
  • Research Article
  • Citations1

3D Brachial Plexus Neurography With Variable-Rate Selective Excitation RF Pulses.

  • Apr 14, 2026
  • Journal of magnetic resonance imaging : JMRI
  • Emma J Mckinney +12
  • Research Article
  • Citations17

New spatial localization method using pulsed high‐order field gradients (SHOT: Selection with high‐order gradient)

  • Mar 01, 1991
  • Magnetic Resonance in Medicine
  • C H Oh +3
  • PDF
  • Discussion
  • Citations1

Reply to 'Enhancing a phase measurement by sequentially probing a solid-state system'.

  • May 09, 2016
  • Nature Communications
  • Gang-Qin Liu +5
  • Conference Article
  • Citations16

Detection of faulty components on power lines using radio frequency signatures and signal processing techniques

  • Jan 23, 2000
  • S Shihab +1
  • Research Article

High Resolution Contrast-Enhanced MR Angiography in the Evaluation of Rabbit Carotid Artery

  • Dec 01, 2005
  • Rivista di Neuroradiologia
  • R.-H Wu +1
  • Research Article
  • Citations17

Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses.

  • Jun 23, 2010
  • Journal of magnetic resonance imaging : JMRI
  • Jing Yuan +3
  • Research Article

Quick injection combining with slow infusion of contrast media on coronary MR angiography

  • May 10, 2010
  • Chinese journal of radiology
  • Tao Li +6
  • Research Article
  • Citations77

Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography.

  • Oct 01, 2001
  • Magnetic Resonance in Medicine
  • Peter Börnert +6
  • PDF
  • Research Article
  • Citations1

Pencil beam excitation using a 2D spatially selective adiabatic T2-prep for imaging the left coronary arterial system

  • Jan 01, 2014
  • Journal of Cardiovascular Magnetic Resonance
  • Andrew J Coristine +1
  • Research Article
  • Citations10

A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging.

  • Oct 31, 2015
  • Magnetic Resonance in Medicine
  • Rebecca E Feldman +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.