• Home
  • Search
  • A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging.
  • Cite Icon10
  • https://doi.org/10.1002/mrm.26025Copy DOI Icon

A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

MR spectroscopic imaging (MRSI) benefits from operation at 7T due to increased signal-to-noise ratio (SNR) and spectral separation. The 180° radiofrequency (RF) pulses used in the conventional MRSI sequences are particularly susceptible to the variation in the transmitted RF (B1 ) field and severe chemical shift localization errors at 7T. RF power deposition, as measured by specific absorption rate (SAR), also increases with field strength. Adiabatic 180° RF pulses may mitigate the effects of B1 variation. We designed and implemented a semiadiabatic spectral-spatial spectroscopic imaging (SASSI) pulse sequence to provide more uniform spectral data at 7T with reduced SAR. The adiabatic Shinnar-Le Roux algorithm was used to generate a high bandwidth 180° adiabatic spectral-spatial (SPSP) pulse that captured a spectral range containing the main metabolites of interest. A pair of 180° SPSP pulses was used to refocus the signal excited by a 90° SPSP pulse in order to select a 3D volume of interest in the SASSI sequence. The SASSI pulse sequence produced spectra with more uniform brain metabolite SNR when compared with the conventional nonadiabatic MRSI sequence. SASSI achieved comparable SNR to the current adiabatic alternative, semi-LASER, but with 1/3 of the SAR. Magn Reson Med 76:1071-1082, 2016. © 2015 Wiley Periodicals, Inc.

Similar Papers
  • PDF
  • Research Article
  • Citations58

Functional Magnetic Resonance Imaging in Conscious Animals: A New Tool in Behavioural Neuroscience Research

  • Mar 28, 2006
  • Journal of Neuroendocrinology
  • Cf Ferris +8
  • Research Article
  • Citations1

EVALUATION OF SPECIFIC ABSORPTION RATE AMONG PATIENTS USING 3 TESLA AND 1.5 TESLA MAGNETIC RESONANCE IMAGING MACHINES

  • Jun 23, 2020
  • Journal of Southeast Asian Medical Research
  • Supakajee Saengruang-Orn +1
  • Book Chapter

The gVERSE RF Pulse: An Optimal Approach to MRI Pulse Design

  • Jan 01, 2008
  • Christopher K Anand +2
  • Conference Article
  • Citations1

Calculation of SAR and B/sub 1/-field within human head excited by MRI birdcage coils

  • Jul 13, 1997
  • J Chen +1
  • PDF
  • Discussion
  • Citations1

Reply to 'Enhancing a phase measurement by sequentially probing a solid-state system'.

  • May 09, 2016
  • Nature Communications
  • Gang-Qin Liu +5
  • Research Article
  • Citations42

Designing adiabatic radio frequency pulses using the Shinnar–Le Roux algorithm

  • Aug 25, 2010
  • Magnetic Resonance in Medicine
  • Priti Balchandani +2
  • Research Article
  • Citations33

Radiofrequency Safety for Interventional MRI Procedures 1

  • Aug 18, 2005
  • Academic Radiology
  • Ergin Atalar
  • Research Article
  • Citations44

Slice accelerated diffusion‐weighted imaging at ultra‐high field strength

  • Jun 24, 2013
  • Magnetic Resonance in Medicine
  • Cornelius Eichner +7
  • Research Article
  • Citations10

B0‐informed variable density trajectory design for enhanced correction of off‐resonance effects in parallel transmission

  • May 28, 2013
  • Magnetic Resonance in Medicine
  • Rainer Schneider +3
  • Research Article
  • Citations29

Magnetic Resonance Imaging and Spectroscopic Imaging of Prostate Cancer

  • Jan 01, 2001
  • Cancer Investigation
  • Mark G Swanson +3
  • Research Article
  • Citations56

Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique.

  • Sep 28, 1999
  • Magnetic Resonance in Medicine
  • Nan-Kuei Chen +1
  • Research Article
  • Citations17

New spatial localization method using pulsed high‐order field gradients (SHOT: Selection with high‐order gradient)

  • Mar 01, 1991
  • Magnetic Resonance in Medicine
  • C H Oh +3
  • Conference Article

A Fast Method to Estimate Peak Local SAR under MRI With RF Shimming

  • Jul 01, 2019
  • Shuo Song +2
  • Research Article
  • Citations396

Correlation of Proton MR Spectroscopic Imaging with Gleason Score Based on Step-Section Pathologic Analysis after Radical Prostatectomy

  • Mar 01, 2005
  • Radiology
  • Kristen L Zakian +11
  • Research Article
  • Citations48

Proton magnetic resonance spectroscopic images and MRI volumetric studies for lateralization of temporal lobe epilepsy

  • Jan 01, 1995
  • Magnetic Resonance Imaging
  • Fernando Cendes +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.