• Home
  • Search
  • Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique.
  • Cite Icon56
  • https://doi.org/10.1002/(sici)1522-2594(199910)42:4<807::aid-mrm25>3.0.co;2-8Copy DOI Icon

Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A technique is proposed to compensate for the slice dephasing artifact and improve the signal-to-noise ratio (SNR) of gradient-echo images. This method is composed of two components: mapping of the internal gradient and design of the slice-selective radiofrequency (RF) pulse. The RF pulse is designed with its phase response as the negative of the product of a chosen echo time and the intravoxel internal gradient profile in a specified region of interest (ROI). The designed RF pulse can refocus the spin phases at a selected echo time and therefore effectively recover the signal loss due to both linear and nonlinear internal gradients. Principles, implementation, and application of the method are described in this note. Magn Reson Med 42:807-812, 1999.

Similar Papers
  • PDF
  • Research Article
  • Citations58

Functional Magnetic Resonance Imaging in Conscious Animals: A New Tool in Behavioural Neuroscience Research

  • Mar 28, 2006
  • Journal of Neuroendocrinology
  • Cf Ferris +8
  • Research Article
  • Citations42

Designing adiabatic radio frequency pulses using the Shinnar–Le Roux algorithm

  • Aug 25, 2010
  • Magnetic Resonance in Medicine
  • Priti Balchandani +2
  • Research Article
  • Citations22

MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system

  • Apr 30, 2018
  • Physics in Medicine & Biology
  • Negar Omidvari +5
  • Research Article
  • Citations10

B0‐informed variable density trajectory design for enhanced correction of off‐resonance effects in parallel transmission

  • May 28, 2013
  • Magnetic Resonance in Medicine
  • Rainer Schneider +3
  • Research Article
  • Citations10

A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging.

  • Oct 31, 2015
  • Magnetic Resonance in Medicine
  • Rebecca E Feldman +1
  • PDF
  • Discussion
  • Citations1

Reply to 'Enhancing a phase measurement by sequentially probing a solid-state system'.

  • May 09, 2016
  • Nature Communications
  • Gang-Qin Liu +5
  • PDF
  • Research Article
  • Citations6

Breath-holding during the Calibration Scan Improves the Reproducibility of Parallel Transmission at 7T for Human Brain

  • Mar 21, 2016
  • Magnetic Resonance in Medical Sciences
  • Taisuke Harada +7
  • Conference Article
  • Citations16

Detection of faulty components on power lines using radio frequency signatures and signal processing techniques

  • Jan 23, 2000
  • S Shihab +1
  • Research Article
  • Citations1

Multidimensional RF pulse design using auto-differentiable spin-domain optimization and its application to reduced field-of-view imaging.

  • Jun 16, 2025
  • Magnetic resonance in medicine
  • Jiayao Yang +3
  • Preprint Article

Inspecting internal magnetic field gradients in volcanic rocks

  • Mar 28, 2022
  • Nadjib Chibati +1
  • Research Article
  • Citations7

The effective phase of soft RF pulses

  • Jul 01, 2014
  • Concepts in Magnetic Resonance Part A
  • Franciszek Hennel
  • Research Article
  • Citations9

Implant hyperthermia resonant circuit produces heat in response to MRI unit radiofrequency pulses

  • Nov 12, 2007
  • The British Journal of Radiology
  • T Niwa +5
  • Research Article
  • Citations1

3D Brachial Plexus Neurography With Variable-Rate Selective Excitation RF Pulses.

  • Apr 14, 2026
  • Journal of magnetic resonance imaging : JMRI
  • Emma J Mckinney +12
  • Research Article
  • Citations11

Combined T2 -preparation and two-dimensional pencil-beam inner volume selection.

  • Aug 27, 2014
  • Magnetic resonance in medicine
  • Andrew J Coristine +2
  • Research Article

Measurement of electromagnetic fields generated by air traffic control radar systems with spectrum analysers

  • Oct 28, 2009
  • Radiation Protection Dosimetry
  • A Barellini +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.