A-401 Performance Evaluation of POCT Equipment for Blood Gas Measurement and Metabolic Parameters

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Abstract Background According to the Clinical & Laboratory Standards Institute (CLSI) guideline, Point of Care technology (POCT) refers to devices used to provide clinical parameters at the site of a patient care or its proximity, allowing faster test results and improving medical response. However, the improvement in clinical outcomes depends on how healthcare professionals utilize this advantage and the performance of the chosen system. With a vast and growing scope, POCT devices enable the analysis of a wide range of analytes, including cardiac markers, coagulation markers, glucose, blood gases, chemical and metabolic parameters, among others. The Stat Profile Prime® analyzer, which exhibits POCT characteristics, offers benefits to patient care, especially during emergency periods and in restricted situations related to patient movement for conducting tests. In this context, the analytical verification of the device is important to clarify the process, the risks associated with the use of the equipment as well as suitability for the intended use. Moreover, performance evaluation ensures the quality and safety of the results obtained from the tests carried out. This study aimed to evaluate the performance of the POCT Stat Profile Prime equipment to measure blood gases and metabolic parameters. Methods Verification tests were conducted between October and December 2024 based on the CLSI-POCT09-A protocol. Precision study was assayed using three commercial control levels, used to monitor the performance of the Stat Profile Prime (Prime Auto QC Cartridge CCS), in quintuplicate over 5 days, for the quantitative determination of the parameters pH, PCO2, PO2, Htc, Na+, K+, Cl-, iCa, Gli (glucose), and Lac (lactate). The acceptance criteria for this analysis included the coefficient of variation (CV) or standard deviation (SD) according to the manufacturer*s specifications. For the comparative study, two sample groups were used: 42 heparinized whole blood samples and 34 serum samples for iCa. Both sample groups were tested on the Gem 3500 (Werfen) and Stat Profile Prime (Nova Biomedical) instruments. The allowable total error and correlation (r = 0.95) were considered approval criteria for the major of tested analytes and Kappa index (= 75%) for Htc. The linearity study was determined using four levels of the linearity standards (Nova Linearity Levels set), which were processed in three replicates, with the expected correlation of r = 0.99. Results The precision tests performed with 3 control levels showed a confidence interval greater than 95% and SD and CV close to the values specified by the manufacturer, indicating satisfactory performance for all evaluated parameters. In the comparative study, the tested parameters showed a correlation = 0.95, displaying 95% of the results within the total allowable error (TEa), and a Kappa index of 79.3% for Htc. According to quality specifications, the parameters from linearity study demonstrated a correlation = 0.99. Conclusion The Stat Profile Prime device demonstrated reliable performance and verification data in accordance with quality standards, ensuring safety and efficiency for clinical use. Furthermore, as a POCT, the equipment provides prompt and accurate results, which is crucial in a hospital environment, improving patient care.

Similar Papers
  • Research Article
  • Citations2

Beyond the basics: Sigma scores in laboratory medicine with variable total allowable errors (TEa)

  • Sep 24, 2024
  • Clinica Chimica Acta
  • Dharmveer Yadav +4
  • Research Article

Evaluation of clinical biochemical laboratory analytical process performance using sigma metrics and quality goal index

  • Dec 30, 2021
  • Chinese Journal of Medical Research
  • Rogious Mbasani +2
  • PDF
  • Research Article

Correlation between GEM Premier 3000 and Vitros5.1+5600, SYSMEX XN-9000 in Detecting Electrolytes and Red Blood Cell Volume

  • Jan 01, 2022
  • Journal of Biomedical Science and Engineering
  • Weihua Xue +1
  • PDF
  • Research Article
  • Citations12

The application of sigma metrics in the laboratory to assess quality control processes in South Africa

  • Jun 22, 2022
  • African Journal of Laboratory Medicine
  • Marli Van Heerden +2
  • Research Article

Impact of blood collection devices and mode of transportation on peripheral venous blood gas parameters

  • Jul 01, 2023
  • Clinica Chimica Acta
  • Raffick A.R Bowen +4
  • Research Article
  • Citations13

Sample size and rejection limits for detecting reagent lot variability: analysis of the applicability of the Clinical and Laboratory Standards Institute (CLSI) EP26-A protocol to real-world clinical chemistry data.

  • Jul 06, 2020
  • Clinical Chemistry and Laboratory Medicine (CCLM)
  • Sollip Kim +5
  • Research Article

Selection of the Primary Quality Control Rules Based on Total Allowable Error and Total Error (by Hand or Laptop)

  • Apr 01, 2018
  • American Society for Clinical Laboratory Science
  • David Plaut
  • Research Article
  • Citations3

Reevaluating the Icterus Index Cutoff of a Jaffé Creatinine Method.

  • Jul 28, 2022
  • The journal of applied laboratory medicine
  • Yasel F Alvarez +4
  • Research Article

Discrepancies in Sigma Metrics Driven by Total Allowable Error Variability: Implications for QC Strategy and Laboratory Efficiency.

  • Nov 18, 2025
  • The journal of applied laboratory medicine
  • Mariem Othmani +5
  • Research Article
  • Citations1

Portable Cholesterol Analyzers-Reply

  • Sep 05, 1990
  • JAMA: The Journal of the American Medical Association
  • Michelle J Naughton
  • Research Article

Comparison of Clinical Chemistry Analysers ERBA XL-640 vs ERBA XL-1000 for Glucose Estimation

  • Jan 01, 2022
  • NATIONAL JOURNAL OF LABORATORY MEDICINE
  • Sheetal Paresh Patel +4
  • Abstract

Why Analytical Performance Specifications are Important and How They Can Be Established

  • Feb 01, 2019
  • Pathology
  • Sverre Sandberg
  • PDF
  • Research Article
  • Citations14

Comparison of blood ethanol stabilities in different storage periods

  • Feb 15, 2015
  • Biochemia Medica
  • Fatma Emel Kocak +3
  • Research Article
  • Citations52

Reference Values for 30 Common Biochemistry Analytes Across 5 Different Analyzers in Neonates and Children 30 Days to 18 Years of Age.

  • Oct 01, 2019
  • Clinical Chemistry
  • Monsurul Hoq +9
  • Research Article

B-160 Quality control proceduret to assure a defined level of medically relevant quality

  • Oct 02, 2025
  • Clinical Chemistry
  • Frederick Smith
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.