In Reply.— With regard to Dr Tetrault's letter, the ±14.2% acceptable range that we used in our study is the correct, total allowable error for a single cholesterol measurement. We refer interested readers to the February 1990 Laboratory Standardization Panel report, which outlines these guidelines for cholesterol measurement. 1 Also, 100% of the cholesterol measurements need to fall within the ± 14.2% range. Dr Tetrault's interpretation of the range for total allowable error is incorrect. The laboratory cholesterol values that we used as a measure of the study participants' true cholesterol levels were adjusted to control for a 5% positive bias found in the measurement method used in our Centers for Disease Control reference laboratory. The precision estimate for the reference method was small (1.3%). We did not assume that our laboratory method was completely without error. Postural and temporal effects can be factors in blood measurements and are rarely

Similar Papers
  • Research Article
  • Citations2

Beyond the basics: Sigma scores in laboratory medicine with variable total allowable errors (TEa)

  • Sep 24, 2024
  • Clinica Chimica Acta
  • Dharmveer Yadav +4
  • Research Article

Evaluation of clinical biochemical laboratory analytical process performance using sigma metrics and quality goal index

  • Dec 30, 2021
  • Chinese Journal of Medical Research
  • Rogious Mbasani +2
  • PDF
  • Research Article
  • Citations12

The application of sigma metrics in the laboratory to assess quality control processes in South Africa

  • Jun 22, 2022
  • African Journal of Laboratory Medicine
  • Marli Van Heerden +2
  • Research Article

A-401 Performance Evaluation of POCT Equipment for Blood Gas Measurement and Metabolic Parameters

  • Oct 02, 2025
  • Clinical Chemistry
  • Debora Ramadan-Boscolo +6
  • PDF
  • Research Article

Correlation between GEM Premier 3000 and Vitros5.1+5600, SYSMEX XN-9000 in Detecting Electrolytes and Red Blood Cell Volume

  • Jan 01, 2022
  • Journal of Biomedical Science and Engineering
  • Weihua Xue +1
  • Research Article
  • Citations3

Reevaluating the Icterus Index Cutoff of a Jaffé Creatinine Method.

  • Jul 28, 2022
  • The journal of applied laboratory medicine
  • Yasel F Alvarez +4
  • Research Article

Discrepancies in Sigma Metrics Driven by Total Allowable Error Variability: Implications for QC Strategy and Laboratory Efficiency.

  • Nov 18, 2025
  • The journal of applied laboratory medicine
  • Mariem Othmani +5
  • Research Article

Comparison of Clinical Chemistry Analysers ERBA XL-640 vs ERBA XL-1000 for Glucose Estimation

  • Jan 01, 2022
  • NATIONAL JOURNAL OF LABORATORY MEDICINE
  • Sheetal Paresh Patel +4
  • Abstract

Why Analytical Performance Specifications are Important and How They Can Be Established

  • Feb 01, 2019
  • Pathology
  • Sverre Sandberg
  • Research Article

B-160 Quality control proceduret to assure a defined level of medically relevant quality

  • Oct 02, 2025
  • Clinical Chemistry
  • Frederick Smith
  • Research Article

Selection of the Primary Quality Control Rules Based on Total Allowable Error and Total Error (by Hand or Laptop)

  • Apr 01, 2018
  • American Society for Clinical Laboratory Science
  • David Plaut
  • Research Article
  • Citations52

Reference Values for 30 Common Biochemistry Analytes Across 5 Different Analyzers in Neonates and Children 30 Days to 18 Years of Age.

  • Oct 01, 2019
  • Clinical Chemistry
  • Monsurul Hoq +9
  • Research Article

A-397 Creatinine Chaos: When Numbers Fail, Imaging Freezes

  • Oct 02, 2025
  • Clinical Chemistry
  • Madhusudhanan Narasimhan +3
  • Research Article

Effect of hemolysis on D-dimer testing measured with the Improgen kit: is all manufacturer information correct?

  • Jul 03, 2024
  • Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis
  • Merve Sena Odabasi
  • Discussion

Are discordant cTnI results detected in an analytical comparison clinically irrelevant?

  • May 05, 2023
  • Clinical Biochemistry
  • Carel J Pretorius +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.