• Home
  • Search
  • A Comparison Of Wearable Physiological Sensors That Estimate Core Temperature In Simulated Hot Work Conditions
  • https://doi.org/10.1249/01.mss.0001157696.77153.0bCopy DOI Icon

A Comparison Of Wearable Physiological Sensors That Estimate Core Temperature In Simulated Hot Work Conditions

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Wearable physiological sensors (WPS) can provide real-time, continuous data to make immediate safety decisions based on how workers respond under a given heat exposure. Estimated core temperature (TEST) calculated from WPS can provide meaningful data on heat illness, strain, and risk, but they must be validated against gold standard measures and during intermittent physical activity in the heat. Two TEST algorithm models (2013 and 2020) are commonly used to assess heat strain in warfighters using heart rate in WPS; however, these models may have limitations when applied to non-military populations. PURPOSE: To examine the validity of TEST (2013 and 2020) compared to a validated measure [rectal temperature (TREC)] during physical activity in the heat in physically active men. METHODS: Twelve healthy men [age, 32 ± 7 years; peak oxygen consumption (VO2peak), 48.19 ± 7.09 ml·kg−1·min−1] completed four experimental trials (~4.5 hours) consisting of cycles of intermittent exercise. WPS were placed at three different locations [chest strap (CS), armband (AB), and wristwatch (WW)] and each incorporated TEST 2013 and 2020. Bland-Altman plots and linear regression were utilized to measure mean difference (MD), 95% limits of agreement (LoA), and coefficient of determination (R2), respectively. TREC was used as the reference measurement. An acceptable MD was determined as ≤0.27 °C. Data were also stratified by TREC value (<38.0 °C, 38.0-38.5 °C, 38.5-39.0 °C, 39.0-39.5 °C, >39.5 °C). RESULTS: The lowest and only acceptable MD was noted in CS, AB, and WW devices that utilized TEST 2020 (0.21 °C, 0.19 °C, 0.27 °C, respectively). For all WPS, 95% of the data fell between MD of -0.54 and 1.22 °C (95% LoA). R2 for all WPS ranged from 0.32-0.39. Poor agreement (>0.27 °C) occurred above 38.5 °C across all WPS TEST 2020 (CS:0.53-0.73 °C, AB: 0.52- 0.74 °C, WW:0.67-0.97 °C). CONCLUSION: Overall, WPS utilizing TEST 2020 demonstrated acceptable MD, but exhibited moderate variability, reflected by R2 values. As TREC increased above 38.5 °C, the MD for all WPS TEST 2020 was greater than the acceptable MD, thus indicating that WPS utilized in this study may not be acceptable for hyperthermic individuals performing intermittent work in the heat. Supported by: This study was funded by Vigilife.

Similar Papers
  • Dissertation

Validity and reliability of two core temperature measurement techniques during physical exercise in the heat: CORE SENSOR and EXERGEN TAT-5000

  • Dec 20, 2023
  • William Martins Januário
  • Conference Article

Label Disambiguation and Sequence Modeling for Identifying Human Activities from Wearable Physiological Sensors

  • Jul 01, 2006
  • Wei-Hao Lin +1
  • Research Article
  • Citations26

Automated Detection of Stressful Conversations Using Wearable Physiological and Inertial Sensors.

  • Dec 17, 2020
  • Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
  • Rummana Bari +5
  • PDF
  • Research Article
  • Citations59

Concurrent heart rate validity of wearable technology devices during trail running

  • Aug 31, 2020
  • PLoS ONE
  • James W Navalta +5
  • Research Article
  • Citations29

Retention of sedentary obese visceral white adipose tissue phenotype with intermittent physical activity despite reduced adiposity.

  • Jul 15, 2015
  • American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
  • Katherine S Wainright +11
  • Research Article
  • Citations7

Feasibility and Accuracy of Wrist-Worn Sensors for Perioperative Monitoring During and After Major Abdominal Surgery: An Observational Study

  • Jul 20, 2024
  • Journal of Surgical Research
  • William Xu +7
  • Research Article
  • Citations11

The practice and potential of heritage emotion research: an experimental mixed-methods approach to investigating affect and emotion in a historic house

  • Jan 23, 2020
  • International Journal of Heritage Studies
  • Jessica Hoare
  • Research Article
  • Citations49

Exploring the effect of urban features and immediate environment on body responses

  • Jun 13, 2019
  • Urban Forestry &amp; Urban Greening
  • Francisco Benita +1
  • Conference Article
  • Citations9

Evaluating virtual reality experience and performance

  • Dec 03, 2016
  • Matthew Pike +1
  • Book Chapter
  • Citations2

Smart Watches for Physiological Monitoring: A Case Study on Blood Pressure Measurement

  • Oct 23, 2016
  • Viswam Nathan +2
  • Research Article
  • Citations23

Individual and Group-wise Classroom Seating Experience

  • Sep 06, 2022
  • Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
  • Nan Gao +4
  • Research Article
  • Citations4

Functional seizure therapy via transauricular vagus nerve stimulation

  • Aug 21, 2024
  • Medical Hypotheses
  • Abhijit Das +1
  • Research Article

213 Performance of Dual PD-L1 Staining in Non-Small Lung Carcinomas

  • Nov 01, 2025
  • American Journal of Clinical Pathology
  • Tammi Holle +3
  • News Article
  • Citations6

Hot Pursuit: New Efforts to Prevent Heat-Related Illness on the Job.

  • Sep 01, 2022
  • Environmental health perspectives
  • Charles W Schmidt
  • Research Article
  • Citations13

Inter-vendor comparison of left atrial strain using layer specific strain analysis.

  • Jan 03, 2021
  • The international journal of cardiovascular imaging
  • Aaisha Ferkh +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.