Abstract

We have developed and fabricated a LTS SQUID gradiometer using Direct writing lithography technology. A niobium thin-film first-order pickup coil is connected to the input coil of a SQUID current sensor via superconducting niobium wire bonds. Both, the fine-scale Josephson junctions and the large-scale pickup coil, are fabricated by this technology. The SQUID is designed as a first-order gradiometer with a dual square washer configuration which was fabricated in a cross-type Josephson junction technology. The inner dimension of each pickup loop is 1.3 cm × 1.3 cm with a baseline of 6.2 cm, which results in a magnetic field gradient sensitivity of 0.3 nT/(cm·Φ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> ). The white noise of the SQUID gradiometer is measured to be 2.6 μΦ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> /Hz <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> corresponding to a magnetic field gradient noise of 99 fT/(m·Hz <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> ) in the white noise region. We also investigated the gradiometer performance in different environments. The performance specifications could be improved by integrating SQUID and first-order pickup coil on the same chip in the future.

Similar Papers
  • Research Article
  • Citations4

Characterization of dual high transition temperature superconducting quantum interference device first-order planar gradiometers on a chip

  • Sep 15, 2010
  • Journal of Applied Physics
  • Kuen-Lin Chen +3
  • Research Article
  • Citations1

Comparison of Axial Wire-Wound and Planar Thin-Film SQUID-Based Gradiometers for Super-Paramagnetic Relaxometry Measurements

  • Jun 01, 2017
  • IEEE Transactions on Applied Superconductivity
  • W H Anderson +5
  • Research Article
  • Citations36

Measured performance parameters of gradiometers with digital output

  • Mar 01, 1989
  • IEEE Transactions on Magnetics
  • D Drung +4
  • Research Article
  • Citations1

SQUID based multichannel system for brain functional imaging

  • Nov 30, 2012
  • Università degli Studi di Napoli Federico II
  • A Vettoliere
  • Research Article

Direct Imaging of the Nerve and Neuronic Signals

  • Jan 01, 2009
  • Frontiers in Neuroinformatics
  • Rostyslav Sklyar
  • Conference Article
  • Citations3

Integrated dc SQUID Magnetometers in Multichannel Systems for Biomagnetic Imaging

  • Sep 01, 2007
  • Carmine Granata +2
  • Research Article
  • Citations5

Transmission line high-T/sub c/ dc-SQUIDs

  • Jun 01, 1999
  • IEEE Transactions on Appiled Superconductivity
  • S Kuriki +6
  • Book Chapter

Characteristics of High Tc DC SQUID Using Three Junctions

  • Jan 01, 1995
  • Keiji Enpuku +2
  • Research Article
  • Citations6

Development of planar thin film HTSC–SQUID gradiometers for different applications

  • Jul 01, 1998
  • Applied Superconductivity
  • L Dörrer +5
  • Research Article
  • Citations28

Instrumentation for Simultaneous Detection of Low Field NMR and Biomagnetic Signals

  • Jun 01, 2005
  • IEEE Transactions on Appiled Superconductivity
  • A.N Matlachov +7
  • Research Article
  • Citations5

Optimization of pick-up coils for weakly damped SQUID gradiometers**Project supported by the Key Project of Shanghai Zhangjiang National Innovation Demonstration Zone of the Special Development Fund, China (Grant No. 2015-JD-C104-060) and the National Natural Science Foundation of China (Grant No. 61741122).

  • Apr 26, 2018
  • Chinese Physics B
  • Kang Yang +4
  • Research Article
  • Citations6

Development of non-destructive evaluation system using an HTS-SQUID gradiometer for magnetized materials

  • Jan 01, 2012
  • Physics Procedia
  • J Kawano +6
  • Research Article
  • Citations7

Integrated magnetometer with a digital output

  • Mar 01, 1991
  • IEEE Transactions on Magnetics
  • H Matz +6
  • Research Article
  • Citations61

A single-chip SQUID magnetometer

  • Jan 01, 1988
  • IEEE Transactions on Electron Devices
  • N Fujimaki +3
  • Research Article
  • Citations2

A high-T/sub c/ second-order gradiometer for use in an unshielded environment

  • Jun 01, 2003
  • IEEE Transactions on Appiled Superconductivity
  • P.P Broussov +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.