• Home
  • Search
  • Integrated dc SQUID Magnetometers in Multichannel Systems for Biomagnetic Imaging
  • Cite Icon3
  • https://doi.org/10.1109/eurcon.2007.4400594Copy DOI Icon

Integrated dc SQUID Magnetometers in Multichannel Systems for Biomagnetic Imaging

  • Sep 1, 2007
  • Carmine Granata +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Improved design and reliable procedures to fabricate low noise superconducting quantum interference device (SQUID) magnetometers, based on niobium technology, have been developed. An improvement in magnetometer performances has been achieved by increasing the flux capture area of the pick-up coil loop together with a much higher SQUID inductance, in order to increase the mutual inductance between the input coil and the washer. In such a way an effective area of 3 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , corresponding to a field-to-flux conversion efficiency of 0.7 nT/Phi <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> has been obtained. In order to reduce the cross-talk in systems consisting of a large number of SQUIDs a new feedback coil design has been developed. Furthermore a full additional positive feedback (APF) circuit has been integrated on the same chip together with a feedback coil for flux-locked-loop (FLL) operations. Such devices exhibit a magnetic field sensitivity as low as 1.5 fT/Hz <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> in white noise region. The temperature dependence of sensor sensitivity is also reported. The measurements show a slow increasing of the field noise up to temperatures of about 5 K, giving a considerable tolerance of the working temperature of niobium magnetometers assembled in vacuum as in some innovative multichannel systems for magnetoencephalography. Due to their compactness and good performances, such devices well meet the requirements of large multichannel systems for biomagnetic imaging.

Similar Papers
  • Research Article
  • Citations10

Effect of an input coil microwave resonance on dynamics and noise properties of a dc superconducting quantum interference device operating close to the hysteretic mode

  • Mar 01, 1999
  • Review of Scientific Instruments
  • V Polushkin +3
  • Research Article
  • Citations3

Superconducting Quantum Interference Device Voltage Swing Related to Additional Positive Feedback Parameters

  • Nov 01, 1994
  • Japanese Journal of Applied Physics
  • Youichi Takada +2
  • Research Article
  • Citations2

Superconducting quantum interference devices with different damped junctions operated in directly coupled current- and voltage-bias modes

  • Sep 24, 2014
  • Chinese Physics B
  • Jia Zeng +6
  • Research Article
  • Citations3

Optical fiber feedback SQUID magnetometer

  • Apr 01, 1989
  • IEEE Transactions on Instrumentation and Measurement
  • S Naito +2
  • Research Article
  • Citations2

Improved Fabrication Process for Monolithic Integrated High-Tc dc Superconducting Quantum Interference Devices

  • Jul 01, 2007
  • Japanese Journal of Applied Physics
  • Yoshihiro Ishimaru +4
  • Research Article
  • Citations6

Development of planar thin film HTSC–SQUID gradiometers for different applications

  • Jul 01, 1998
  • Applied Superconductivity
  • L Dörrer +5
  • PDF
  • Research Article
  • Citations17

Graphene-based tunable SQUIDs

  • Apr 17, 2017
  • Applied Physics Letters
  • M D Thompson +8
  • Research Article
  • Citations3

Possible Pitfalls in SQUID Magnetometry of Superconducting Samples: The Case of RuSr2GdCu2O8

  • Jan 01, 2003
  • Journal of Low Temperature Physics
  • T P Papageorgiou +2
  • Single Report

Low-frequency noise in high-T&lt;sub&gt;c&lt;/sub&gt; superconductor Josephson junctions, SQUIDs, and magnetometers

  • May 01, 1994
  • Andrew Hostetler Miklich
  • Research Article
  • Citations71

Multilevel YBaCuO flux transformers with high T c SQUIDs: A prototype high T c SQUID magnetometer working at 77 K

  • Jul 01, 1991
  • Applied Physics Letters
  • B Oh +4
  • Research Article
  • Citations12

Reliable low noise DC-SQUID

  • Mar 01, 1989
  • IEEE Transactions on Magnetics
  • P Carelli +3
  • Research Article
  • Citations1

Comparison between the magnetization obtained from Faraday balance and VSM or SQUID

  • Sep 01, 1992
  • IEEE Transactions on Magnetics
  • M Dababneh +3
  • Research Article
  • Citations32

Modeling the direct current superconducting quantum interference device coupled to the multiturn input coil. II

  • Mar 01, 1992
  • Journal of Applied Physics
  • K Enpuku +2
  • Research Article
  • Citations1

Integrated Directly-Coupled SQUID Magnetometer and Gradiometer

  • Jan 01, 2012
  • Physics Procedia
  • Chan-Yao Chang +2
  • Research Article
  • Citations2

Effect of critical current spread on the noise performance of SQUID magnetometers: An experimental study

  • Oct 24, 2018
  • Physica C: Superconductivity and its Applications
  • A Vettoliere +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.