Comparison between the magnetization obtained from Faraday balance and VSM or SQUID

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The authors derive a relation between the magnetization obtained using a vibrating sample magnetometer (VSM) or a superconducting quantum interference device (SQUID) magnetometer and the magnetization obtained using a Faraday balance (FB). It is shown that, to a first approximation, the magnetization obtained using a FB should be very close to those obtained using VSM or SQUID, especially for short samples and low field. The variation of the magnetization with the sample length is presented at low and intermediate fields.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Similar Papers
  • Research Article
  • Citations5

Linearity of sensitive YBa2Cu3O7−x dc superconducting quantum interference device magnetometers

  • Sep 15, 1999
  • Journal of Applied Physics
  • J Beyer +3
  • Research Article
  • Citations30

Miniature anvil cell for high-pressure measurements in a commercial superconducting quantum interference device magnetometer

  • Feb 01, 2009
  • Review of Scientific Instruments
  • Patricia Lebre Alireza +1
  • PDF
  • Research Article
  • Citations4

A Remote Two-Point Magnetic Localization Method Based on SQUID Magnetometers and Magnetic Gradient Tensor Invariants.

  • Sep 12, 2024
  • Sensors (Basel, Switzerland)
  • Yingzi Zhang +5
  • Research Article
  • Citations3

Possible Pitfalls in SQUID Magnetometry of Superconducting Samples: The Case of RuSr2GdCu2O8

  • Jan 01, 2003
  • Journal of Low Temperature Physics
  • T P Papageorgiou +2
  • Research Article
  • Citations2

A stabilizer for superconducting quantum interference device gradiometers for operation in lightly shielded environments

  • Apr 29, 2003
  • Applied Physics Letters
  • Koichi Yokosawa +5
  • Research Article
  • Citations13

Low Field MRI Detection With Tuned HTS SQUID Magnetometer

  • Jun 01, 2011
  • IEEE Transactions on Applied Superconductivity
  • Hui Dong +4
  • Research Article
  • Citations14

Biomagnetic and bioelectric detection of gastric slow wave activity in normal human subjects—a correlation study

  • Jun 27, 2012
  • Physiological Measurement
  • S Somarajan +4
  • Research Article
  • Citations99

Solid-state systems for the electron electric dipole moment and other fundamental measurements

  • Aug 15, 2002
  • Physical Review A
  • S K Lamoreaux
  • Research Article
  • Citations3

Optical fiber feedback SQUID magnetometer

  • Apr 01, 1989
  • IEEE Transactions on Instrumentation and Measurement
  • S Naito +2
  • Research Article
  • Citations34

Magnetic detection of photogenerated currents in semiconductor wafers using superconducting quantum interference devices

  • May 10, 1999
  • Applied Physics Letters
  • J Beyer +3
  • Research Article
  • Citations32

Development of high-pressure and high-field ESR system using SQUID magnetometer

  • Aug 10, 2012
  • Journal of Magnetic Resonance
  • T Sakurai +5
  • Research Article
  • Citations4

An overview of advanced instruments for magnetic characterization and measurements

  • Sep 01, 2025
  • Frontiers in Electronics
  • Junbiao Zhao +10
  • Conference Article
  • Citations1

A Ground‐Based SQUID Magnetometer

  • Jan 01, 2005
  • W E Doll +4
  • Research Article
  • Citations2

PSIM simulations of a dc SQUID magnetometer

  • May 05, 2015
  • Journal of Engineering, Design and Technology
  • Kehinde Ogunyanda +2
  • Research Article
  • Citations29

Improvement of SQUID Magnetometer System for Extending Application of Spinal Cord Evoked Magnetic Field Measurement

  • Jun 01, 2011
  • IEEE Transactions on Applied Superconductivity
  • Yoshiaki Adachi +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.