• Home
  • Search
  • Linearity of sensitive YBa2Cu3O7−x dc superconducting quantum interference device magnetometers
  • Cite Icon5
  • https://doi.org/10.1063/1.371217Copy DOI Icon

Linearity of sensitive YBa2Cu3O7−x dc superconducting quantum interference device magnetometers

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The linearity of sensitive superconducting quantum interference device (SQUID) magnetometers fabricated from high critical temperature (high-Tc) superconductors and operated in a direct-coupled flux-locked loop with bias reversal was investigated. The system nonlinearity was determined by applying a sinusoidal test signal and measuring the output signal harmonics using a setup which ensures the elimination of nonlinearities arising from the test signal source and the spectrum analyzer. The experimental setup enables the simultaneous measurement of the harmonic distortion of a single magnetometer and of a first-order electronic gradiometer formed by two individual magnetometers. Test signal amplitudes and frequencies were chosen to simulate typical laboratory interferences. An analysis of the results was performed using analytical equations in which the SQUID’s inherent nonlinear character is taken into account. At signal frequencies above about 0.1% of the system bandwidth, the system nonlinearity was found to be mainly caused by the nonlinear behavior of the SQUID magnetometers, whereas at low frequencies nonlinearities arising from read-out electronics components predominate. For signal peak-to-peak amplitudes up to 1 μT and frequencies up to 0.5 kHz, total harmonic distortions below about −105 dB for a single sensor channel and −100 dB for an electronic gradiometer were obtained.

Similar Papers
  • Research Article
  • Citations30

Miniature anvil cell for high-pressure measurements in a commercial superconducting quantum interference device magnetometer

  • Feb 01, 2009
  • Review of Scientific Instruments
  • Patricia Lebre Alireza +1
  • PDF
  • Research Article
  • Citations4

A Remote Two-Point Magnetic Localization Method Based on SQUID Magnetometers and Magnetic Gradient Tensor Invariants.

  • Sep 12, 2024
  • Sensors (Basel, Switzerland)
  • Yingzi Zhang +5
  • Research Article
  • Citations2

A stabilizer for superconducting quantum interference device gradiometers for operation in lightly shielded environments

  • Apr 29, 2003
  • Applied Physics Letters
  • Koichi Yokosawa +5
  • Research Article
  • Citations34

Magnetic detection of photogenerated currents in semiconductor wafers using superconducting quantum interference devices

  • May 10, 1999
  • Applied Physics Letters
  • J Beyer +3
  • Research Article
  • Citations32

Development of high-pressure and high-field ESR system using SQUID magnetometer

  • Aug 10, 2012
  • Journal of Magnetic Resonance
  • T Sakurai +5
  • Research Article
  • Citations3

Possible Pitfalls in SQUID Magnetometry of Superconducting Samples: The Case of RuSr2GdCu2O8

  • Jan 01, 2003
  • Journal of Low Temperature Physics
  • T P Papageorgiou +2
  • Conference Article

VIBRATION CHARACTERIZATION AND REDUCTION OF A JOULE-THOMSON CRYOCOOLER FOR A SQUID-BASED METAL DETECTION SYSTEM

  • Jan 01, 2008
  • AIP conference proceedings
  • G J J B De Groot +17
  • Research Article
  • Citations1

Comparison between the magnetization obtained from Faraday balance and VSM or SQUID

  • Sep 01, 1992
  • IEEE Transactions on Magnetics
  • M Dababneh +3
  • Research Article
  • Citations2

PSIM simulations of a dc SQUID magnetometer

  • May 05, 2015
  • Journal of Engineering, Design and Technology
  • Kehinde Ogunyanda +2
  • Research Article
  • Citations29

Improvement of SQUID Magnetometer System for Extending Application of Spinal Cord Evoked Magnetic Field Measurement

  • Jun 01, 2011
  • IEEE Transactions on Applied Superconductivity
  • Yoshiaki Adachi +7
  • Research Article
  • Citations14

Biomagnetic and bioelectric detection of gastric slow wave activity in normal human subjects—a correlation study

  • Jun 27, 2012
  • Physiological Measurement
  • S Somarajan +4
  • Research Article
  • Citations99

Solid-state systems for the electron electric dipole moment and other fundamental measurements

  • Aug 15, 2002
  • Physical Review A
  • S K Lamoreaux
  • Research Article
  • Citations18

Thermosensitive Ni-based magnetic particles for self-controlled hyperthermia applications

  • Nov 12, 2016
  • Journal of Magnetism and Magnetic Materials
  • Sudip Pandey +6
  • Research Article
  • Citations3

A Study on High Coercivity and L10Ordered Phase in CoPt and FePt Thin Films

  • Jan 01, 1999
  • MRS Proceedings
  • R A Ristau +4
  • Research Article
  • Citations44

Interband Faraday and Kerr rotation and magnetization ofPb1−xEuxTein the concentration range 0<x⩽1

  • Sep 15, 1999
  • Physical Review B
  • H Krenn +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.