• Home
  • Search
  • Low Field MRI Detection With Tuned HTS SQUID Magnetometer
  • Cite Icon13
  • https://doi.org/10.1109/tasc.2010.2091713Copy DOI Icon

Low Field MRI Detection With Tuned HTS SQUID Magnetometer

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We set up a low field (LF) magnetic resonance imaging (MRI) system with a tuned high- <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">T</i> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> (HTS) superconducting quantum interference device (SQUID) consisting of a SQUID magnetometer and a liquid-nitrogen-cooled <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LC</i> resonant pickup circuit, which are inductively coupled. Around 9 kHz, the configuration enhances the sensitivity of the system to 6-7 fT/√Hz. Meanwhile, the relatively large diameter of the coil <i xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</i> compensates the magnetometer's drawback of a small pickup area. We performed our experiments with a prepolarization field of 10 mT in a magnetically shielded room. The measurement field was 212.2 μT, corresponding to the Larmor frequency of 9.038 kHz. The compromise between the signal-to-noise ratio and the spatial resolution for our system was studied by recording one-dimensional MRI images of carrots under different gradient fields. For the sample of two carrot slices with center distance of 2.8 cm, a gradient field of 20 Hz/cm was suitable. Two-dimensional images were finally acquired. A HTS system for biological LF MRI detection by a tuned SQUID is demonstrated to be feasible.

Similar Papers
  • Research Article
  • Citations10

Tuned HTS SQUID-Detected Low Field MRI Using a Permanent Magnet for Pre-polarization With Automatic Transportation

  • Jun 01, 2013
  • IEEE Transactions on Applied Superconductivity
  • Chao Liu +6
  • Conference Article

Comparison of denoising methods for synthetic low-field neurological MRI

  • Jun 26, 2023
  • Anthony O'Brien +1
  • Research Article
  • Citations13

STANDING LOW‐FIELD MAGNETIC RESONANCE IMAGING APPEARANCE OF NORMAL COLLATERAL LIGAMENTS OF THE EQUINE DISTAL INTERPHALANGEAL JOINT

  • Jun 20, 2011
  • Veterinary Radiology &amp; Ultrasound
  • Santiago D Gutierrez‐Nibeyro +5
  • Research Article
  • Citations52

Lumbar Modic Changes—A Comparison Between Findings at Low- and High-Field Magnetic Resonance Imaging

  • Sep 01, 2012
  • Spine
  • Tom Bendix +5
  • Conference Article
  • Citations13

Improving Image Quality In Low-Field MRI With Deep Learning

  • Sep 19, 2021
  • Armando Garcia Hernandez +6
  • Research Article
  • Citations5

Measurement accuracy of foot conformation parameters on low-field magnetic resonance images in horses

  • Feb 07, 2022
  • Journal of Equine Veterinary Science
  • David M Bolt +4
  • Research Article
  • Citations55

MAGNETIC RESONANCE IMAGING FINDINGS OF DESMOPATHY OF THE COLLATERAL LIGAMENTS OF THE EQUINE DISTAL INTERPHALANGEAL JOINT

  • Dec 23, 2008
  • Veterinary Radiology &amp; Ultrasound
  • Santiago D Gutierrez‐Nibeyro +6
  • Research Article
  • Citations131

Low-Field Magnetic Resonance Imaging

  • Jul 21, 2021
  • Investigative Radiology
  • Masaaki Hori +4
  • Research Article
  • Citations5

Linearity of sensitive YBa2Cu3O7−x dc superconducting quantum interference device magnetometers

  • Sep 15, 1999
  • Journal of Applied Physics
  • J Beyer +3
  • Conference Article
  • Citations4

Very Low Field MRI: A fast system compatible with Magnetoencephalography

  • May 01, 2015
  • A Galante +9
  • PDF
  • Research Article
  • Citations4

A Remote Two-Point Magnetic Localization Method Based on SQUID Magnetometers and Magnetic Gradient Tensor Invariants.

  • Sep 12, 2024
  • Sensors (Basel, Switzerland)
  • Yingzi Zhang +5
  • Research Article
  • Citations2

PSIM simulations of a dc SQUID magnetometer

  • May 05, 2015
  • Journal of Engineering, Design and Technology
  • Kehinde Ogunyanda +2
  • Research Article
  • Citations29

Improvement of SQUID Magnetometer System for Extending Application of Spinal Cord Evoked Magnetic Field Measurement

  • Jun 01, 2011
  • IEEE Transactions on Applied Superconductivity
  • Yoshiaki Adachi +7
  • Research Article
  • Citations30

Miniature anvil cell for high-pressure measurements in a commercial superconducting quantum interference device magnetometer

  • Feb 01, 2009
  • Review of Scientific Instruments
  • Patricia Lebre Alireza +1
  • Research Article
  • Citations1

Comparison between the magnetization obtained from Faraday balance and VSM or SQUID

  • Sep 01, 1992
  • IEEE Transactions on Magnetics
  • M Dababneh +3