A streamlined workflow for comprehensive 4DCT imaging QA with automated analysis of spatial integrity and image quality.

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

A comprehensive 4DCT QA program that includes the assessment of spatial integrity and image quality of 4D phantom scans can be resource-intensive, especially because the analysis burden scales with the number of motion traces used for QA. This work presents a streamlined and scalable workflow, enabled by the use of a widely available phantom and an automated analysis tool. For 4DCT imaging QA, the Catphan was placed on the QUASAR motion platform, driven with sinusoidal motion traces of various amplitudes and frequencies. The acquired image sets were automatically analyzed using a newly designed 4DCT analysis module in TotalQA. The metrics of interest for 4DCT QA were analyzed for image sets of all motion bins and compared to the stationary reference image set. Three broad categories of imaging tests for 4DCT QA were defined: spatial integrity, HU constancy, and image quality. The sensitometry plugs in the Catphan were used as motion surrogates for evaluating spatial integrity, including the dimensions of the plugs and the observed motion amplitude in the scans. HU values of the sensitometry plugs in different phases were evaluated for consistency. For image quality, spatial resolution, low contrast resolution, and image noise were evaluated. Compared to the stationary reference CT, spatial integrity was within ±1mm and the HU values were within two HU in the 4DCT for all phases. The spatial resolution was consistent while slightly higher noise was observed in the 4DCT images. The automated analysis in TotalQA was completed in approximately 20min per motion trace, improving efficiency by more than 80% compared to the manual workflow. A streamlined 4DCT imaging QA workflow with automated analysis offers a robust assessment of imaging quality and motion accuracy in 4DCT scans, enabling an efficient and consistent QA process in large healthcare networks.

Similar Papers
  • Research Article

Analysis of Spatial Vibration on Scanning Mirror Imaging Based on Frequency Filtering

  • Jan 01, 2021
  • IEEE Access
  • Ziqi Yu +2
  • Conference Article
  • Citations5

Perceptual difference paradigm for analyzing image quality of fast MRI techniques

  • May 21, 2003
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • David L Wilson +3
  • Research Article
  • Citations16

Computed tomography angiography in children with cardiovascular disease: low dose techniques and image quality

  • Jan 07, 2011
  • The International Journal of Cardiovascular Imaging
  • S Bruce Greenberg +3
  • Research Article
  • Citations4

Effect of a dedicated PI-QUAL curriculum on the assessment of prostate MRI quality

  • May 08, 2023
  • European Journal of Radiology
  • Richard Wang +19
  • PDF
  • Research Article

Imaging quality assessment of mammograms

  • Aug 31, 2016
  • Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
  • Dmitry Aleksandrovich Boyko
  • Research Article
  • Citations23

MR image quality in local staging of prostate cancer: Role of PI-QUAL in the detection of extraprostatic extension

  • Jul 11, 2023
  • European Journal of Radiology
  • Andrea Ponsiglione +9
  • Supplementary Content

Development and evaluation of a comprehensive QA phantom for image quality and geometrical accuracy in CT and CBCT for radiotherapy

  • Aug 21, 2025
  • Journal of Applied Clinical Medical Physics
  • Minsoo Chun +8
  • Research Article

MO‐D‐213A‐01: ACR Accreditation

  • Jun 01, 2009
  • Medical Physics
  • Carolyn R Macfarlane
  • Research Article
  • Citations16

Comparison of Artificial Intelligence-Assisted Compressed Sensing (ACS) and Routine Two-Dimensional Sequences on Lumbar Spine Imaging

  • Jan 28, 2023
  • Journal of Pain Research
  • He Sui +6
  • Research Article
  • Citations49

Forensic oral imaging quality of hand-held dental X-ray devices: Comparison of two image receptors and two devices

  • Nov 12, 2009
  • Forensic Science International
  • P Pittayapat +4
  • Research Article
  • Citations16

An optimized CNN-based quality assessment model for screen content image

  • Feb 06, 2021
  • Signal Processing: Image Communication
  • Xuhao Jiang +4
  • Research Article
  • Citations2

Quantitative Assessment of Image Quality in 64-slice-computed Tomography of Coronary Arteries in Subjects Undergoing Screening for Coronary Artery Disease

  • Jan 01, 2010
  • Kaohsiung Journal of Medical Sciences
  • Li-Hwa Yang +8
  • Research Article

단순 라플라스 연산자를 사용한 새로운 고속 및 고성능 영상 화질 측정 척도

  • Mar 30, 2016
  • Journal of Broadcast Engineering
  • Sung-Ho Bae +1
  • Research Article
  • Citations22

Spatial resolution and image qualities of Zr-89 on Siemens Biograph TruePoint PET/CT.

  • Dec 30, 2014
  • Cancer biotherapy & radiopharmaceuticals
  • Young Sub Lee +5
  • Research Article
  • Citations8

Brand ferumoxytol vs. generic ferumoxytol comparison across two dosing regimens: a cardiac MRI image quality study.

  • Oct 14, 2023
  • Pediatric Radiology
  • Anoushka Dasi +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.