Localizing and characterizing clinically-significant lung nodules, a potential precursor to lung cancer, at the lowest achievable radiation dose is demanded to minimize the stochastic radiation effects from x-ray computed tomography (CT). A minimal dose level is heavily dependent on the image reconstruction algorithms and clinical task, in which the tissue texture always plays an important role. This study aims to investigate the dependence through a task-based evaluation at multiple dose levels and variable textures in reconstructions with prospective patient studies. 133 patients with a suspicious pulmonary nodule scheduled for biopsy were recruited and the data was acquired at120kVp with three different dose levels of 100, 40 and 20mAs. Three reconstruction algorithms were implemented: analytical filtered back-projection (FBP) with optimal noise filtering; statistical Markov random field (MRF) model with optimal Huber weighting (MRF-H) for piecewise smooth reconstruction; and tissue-specific texture model (MRF-T) for texture preserved statistical reconstruction. Experienced thoracic radiologists reviewed and scored all images at random, blind to the CT dose and reconstruction algorithms. The radiologists identified the nodules in each image including the 133 biopsy target nodules and 66 other non-target nodules. For target nodule characterization, only MRF-T at 40mAs showed no statistically significant difference from FBP at 100mAs. For localizing both the target nodules and the non-target nodules, some as small as 3mm, MRF-T at 40 and 20mAs levels showed no statistically significant difference from FBP at 100mAs, respectively. MRF-H and FBP at 40 and 20mAs levels performed statistically differently from FBP at 100mAs. This investigation concluded that (1) the textures in the MRF-T reconstructions improves both the tasks of localizing and characterizing nodules at low dose CT and (2) the task of characterizing nodules is more challenging than the task of localizing nodules and needs more dose or enhanced textures from reconstruction.

Similar Papers
  • Research Article
  • Citations11

Volumetric measurement of artificial pure ground-glass nodules at low-dose CT: Comparisons between hybrid iterative reconstruction and filtered back projection

  • Sep 03, 2015
  • European Journal of Radiology
  • Noriyuki Sakai +9
  • Research Article
  • Citations7

Dose-efficiency quantification of computed tomography systems using a model-observer.

  • May 14, 2023
  • Medical Physics
  • Maximilian Göppel +6
  • PDF
  • Research Article
  • Citations60

CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction

  • Aug 09, 2013
  • BMC Medical Imaging
  • Yasutaka Ichikawa +4
  • Conference Article

CT image reconstruction on Pi-lines in Parallel-Beam

  • Nov 01, 2013
  • Yang Guiqin +3
  • Research Article
  • Citations14

Iterative CT reconstruction in abdominal low-dose CT used for hybrid SPECT-CT applications: effect on image quality, image noise, detectability, and reader’s confidence

  • Jun 01, 2019
  • Acta Radiologica Open
  • Oliver S Grosser +11
  • Research Article
  • Citations57

Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)

  • Oct 03, 2013
  • Medical Physics
  • Baiyu Chen +5
  • Research Article
  • Citations4

A preliminary evaluation study of applying a deep learning image reconstruction algorithm in low-kilovolt scanning of upper abdomen.

  • Jun 03, 2021
  • Journal of X-ray science and technology
  • Ya-Ning Wang +7
  • Research Article
  • Citations2

Deep learning-based reconstruction improves image quality in low-dose head CT angiography

  • Jul 11, 2025
  • Malawi Medical Journal
  • Xin Huang +7
  • PDF
  • Research Article
  • Citations5

Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study

  • Aug 11, 2022
  • PLoS ONE
  • Sungjin Yoon +7
  • Research Article
  • Citations52

Preserving image texture while reducing radiation dose with a deep learning image reconstruction algorithm in chest CT: A phantom study.

  • Jan 01, 2021
  • Physica Medica
  • Caro Franck +3
  • Conference Article
  • Citations3

Penalized weighted alpha-divergence approach to sinogram restoration for low-dose X-ray computed tomography

  • Oct 01, 2012
  • Zhaoying Bian +7
  • Conference Article
  • Citations1

Generalized iterative sparse-view CT reconstruction with deep neural network

  • Mar 16, 2020
  • Medical Imaging 2020: Physics of Medical Imaging
  • Ting Su +5
  • Research Article
  • Citations10

Image quality evaluation in deep-learning-based CT noise reduction using virtual imaging trial methods: Contrast-dependent spatial resolution.

  • Mar 31, 2024
  • Medical physics
  • Zhongxing Zhou +4
  • Research Article
  • Citations98

Artifact correction in low‐dose dental CT imaging using Wasserstein generative adversarial networks

  • Feb 14, 2019
  • Medical Physics
  • Zhanli Hu +8
  • Research Article
  • Citations7

Improved image quality of low-dose CT combining with iterative model reconstruction algorithm for response assessment in patients after treatment of malignant tumor.

  • Aug 01, 2018
  • Quantitative Imaging in Medicine and Surgery
  • Xiaoyan Xin +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.