Abstract

Deep-learning-based image reconstruction and noise reduction methods (DLIR) have been increasingly deployed in clinical CT. Accurate image quality assessment of these methods is challenging as the performance measured using physical phantoms may not represent the true performance of DLIR in patients since DLIR is trained mostly on patient images. In this work, we aim to develop a patient-data-based virtual imaging trial framework and, as a first application, use it to measure the spatial resolution properties of a DLIR method. The patient-data-based virtual imaging trial framework consists of five steps: (1) insertion of lesions into projection domain data using the acquisition geometry of the patient exam to simulate different lesion characteristics; (2) insertion of noise into projection domain data using a realistic photon statistical model of the CT system to simulate different dose levels; (3) creation of DLIR-processed images from projection or image data; (4) creation of ensembles of DLIR-processed patient images from a large number of noise and lesion realizations; and (5) evaluation of image quality using ensemble DLIR images. This framework was applied to measure the spatial resolution of a ResNet based deep convolutional neural network (DCNN) trained on patient images. Lesions in a cylindrical shape and different contrast levels (-500, -100, -50, -20, -10 HU) were inserted to the lower right lobe of the liver in a patient case. Multiple dose levels were simulated (50%, 25%, 12.5%). Each lesion and dose condition had 600 noise realizations. Multiple reconstruction and denoising methods were used on all the noise realizations, including the original filtered-backprojection (FBP), iterative reconstruction (IR), and the DCNN method with three different strength setting (DCNN-weak, DCNN-medium, and DCNN-strong). Mean lesion signal was calculated by performing ensemble averaging of all the noise realizations for each lesion and dose condition and then subtracting the lesion-present images from the lesion absent images. Modulation transfer functions (MTFs) both in-plane and along the z-axis were calculated based on the mean lesion signals. The standard deviations of MTFs at each condition were estimated with bootstrapping: randomly sampling (with replacement) all the DLIR/FBP/IR images from the ensemble data (600 samples) at each condition. The impact of varying lesion contrast, dose levels, and denoising strengths were evaluated. Statistical analysis with paired t-test was used to compare the z-axis and in-plane spatial resolution of five algorithms for five different contrasts and three dose levels. The in-plane and z-axis spatial resolution degradation of DCNN becomes more severe as the contrast or radiation dose decreased, or DCNN denoising strength increased. In comparison with FBP, a 59.5% and 4.1% reduction of in-plane and z-axis MTF (in terms of spatial frequencies at 50% MTF), respectively, was observed at low contrast (-10 HU) for DCNN with the highest denoising strength at 25% routine dose level. When the dose level reduces from 50% to 12.5% of routine dose, the in-plane and z-axis MTFs reduces from 92.1% to 76.3%, and from 98.9% to 95.5%, respectively, at contrast of -100 HU, using FBP as the reference. For most conditions of contrasts and dose levels, significant differences were found among the five algorithms, with the following relationship in both in-plane and cross-plane spatial resolution: FBP>DCNN-Weak>IR>DCNN-Medium>DCNN-Strong. The spatial resolution difference among algorithms decreases at higher contrast or dose levels. A patient-data-based virtual imaging trial framework was developed and applied to measuring the spatial resolution properties of a DCNN noise reduction method at different contrast and dose levels using real patient data. As with other non-linear image reconstruction and post-processing techniques, the evaluated DCNN method degraded the in-plane and z-axis spatial resolution at lower contrast levels, lower radiation dose, and higher denoising strength.

Similar Papers
  • Research Article
  • Citations25

Enhancement of in-plane spatial resolution in volumetric computed tomography with focal spot wobbling – Overcoming the constraint on number of projection views per gantry rotation

  • Jan 01, 2010
  • Journal of X-Ray Science and Technology
  • Xiangyang Tang +7
  • Research Article
  • Citations52

Preserving image texture while reducing radiation dose with a deep learning image reconstruction algorithm in chest CT: A phantom study.

  • Jan 01, 2021
  • Physica Medica
  • Caro Franck +3
  • PDF
  • Research Article
  • Citations164

Computer-aided diagnosis of lung nodule classification between benign nodule, primary lung cancer, and metastatic lung cancer at different image size using deep convolutional neural network with transfer learning

  • Jul 27, 2018
  • PLoS ONE
  • Mizuho Nishio +6
  • Research Article
  • Citations41

An effective noise reduction method for multi-energy CT images that exploits spatio-spectral features

  • Apr 12, 2017
  • Medical physics
  • Zhoubo Li +4
  • Research Article
  • Citations28

Sensitivity of Myocardial Radiomic Features to Imaging Parameters in Cardiac MR Imaging.

  • Mar 01, 2021
  • Journal of Magnetic Resonance Imaging
  • Jihye Jang +10
  • Abstract

OA158] Noise equivalent number of quanta (NEQ): A tool for choosing the optimal reconstruction algorithm in computed tomography (CT)

  • Aug 01, 2018
  • Physica Medica
  • Vittorio Di Trapani +1
  • Research Article
  • Citations3

Assessment of abdominal organ dose and image quality in varying arc trajectory interventional C-arm cone beam CT

  • Sep 12, 2022
  • Physica Medica
  • Antonios E Papadakis +1
  • Research Article
  • Citations9

Myocardial first‐pass perfusion: Influence of spatial resolution and heart rate on the dark rim artifact

  • Jun 23, 2011
  • Magnetic Resonance in Medicine
  • Antonella Meloni +8
  • Research Article
  • Citations25

Validation of synthesized normal-resolution image data generated from high-resolution acquisitions on a commercial CT scanner.

  • Aug 05, 2020
  • Medical Physics
  • Andrew M Hernandez +8
  • Research Article
  • Citations4

Deep learning-based low-dose CT simulator for non-linear reconstruction methods.

  • Jun 06, 2024
  • Medical physics
  • Sjoerd A M Tunissen +5
  • Research Article

WE-G-17A-01: Improving Tracking Image Spatial Resolution for Onboard MR Image Guided Radiation Therapy Using the WHISKEE Technique

  • May 29, 2014
  • Medical Physics
  • Y Hu +8
  • PDF
  • Research Article
  • Citations19

Deep Convolutional Neural Networks for the Prediction of Molecular Properties: Challenges and Opportunities Connected to the Data

  • Dec 05, 2018
  • Journal of Integrative Bioinformatics
  • Niclas Ståhl +4
  • Research Article
  • Citations67

Comparison of low-contrast detectability between two CT reconstruction algorithms using voxel-based 3D printed textured phantoms.

  • Nov 11, 2016
  • Medical Physics
  • Justin Solomon +3
  • PDF
  • Research Article
  • Citations216

Gas Classification Using Deep Convolutional Neural Networks.

  • Jan 08, 2018
  • Sensors
  • Pai Peng +3
  • Conference Article
  • Citations11

Lightweight Deep Convolutional Neural Networks for Facial Expression Recognition

  • Sep 01, 2019
  • Yanan Wang +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.