Validation of synthesized normal-resolution image data generated from high-resolution acquisitions on a commercial CT scanner.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To validate a normal-resolution (NR) simulation (NRsim) algorithm that uses high-resolution (HR) or super-high resolution (SHR) acquisitions on a commercial HR computed tomography (CT) scanner by comparing image quality between NRsim-generated images and actual NR images. NRsim is intended to allow direct comparison between normal-resolution CT and HR/SHR reconstructions in clinical investigations, without repeating exams. The Aquilion Precision CT (Canon Medical Systems Corporation) HR CT scanner has three resolution modes resulting from detector binning in the channel (x-y) and row (z) directions. For NR, each detector element is 0.5mm×0.5mm along the channel and row directions, 0.25mm×0.5mm for HR, and 0.25mm×0.25mm for SHR. The NRsim algorithm simulates NR acquisitions from HR or SHR acquisitions (termed NRHR and NRSHR , respectively) by downsampling the pre-log raw data in the channel direction for the HR acquisitions and in the channel and row direction for the SHR acquisition. The downsampled data are then reconstructed using the same process as NR. The axial modulation transfer function (MTF), slice sensitivity profile (SSP), and CT number accuracy were measured using the Catphan 600 phantom, and the three-dimensional noise power spectrum (NPS) was measured in water-equivalent phantoms for standard protocols across a range of size-specific dose estimates (SSDE): head (6.2-29.8mGy), lung (2.2-18.2mGy), and body (5.6-19.4mGy). The MTF and NPS measurements were combined to estimate low-contrast detectability (LCD) using a non-prewhitening model observer with an eye filter for a 5-mm disk with 10HU contrast. All metrics were compared for NR, NRHR , and NRSHR images reconstructed using filtered back projection (FBP) and an iterative reconstruction algorithm (AIDR3D). We chose a 15% error threshold as a reasonable definition of success for NRsim when compared against actual NR based on published studies showing that a just-noticeable difference in image noise level for human observers is typically <15%. The axial MTF and SSPs for NRsim were in good agreement with NR demonstrated by a maximum difference of 5.1% for the MTF at 10% and 50% across materials (air, Teflon, LDPE, and polystyrene) and a maximum SSP difference of 2.2%. Noise magnitude differences were within 15% across the SSDE levels with the exception of below 4.5mGy for the lung protocol with FBP. The relative RMSE of normalized NPS comparisons were all <15%. Differences in CT numbers for NRsim reconstructions were within 2HU of NR. LCD for NRsim was within 15% of NR with the exception of NRSHR for the lung protocol SSDE levels below 3.7mGy with FBP. NRsim, an algorithm for simulating NR acquisitions using HR and SHR raw data, was introduced and shown to generate images with spatial resolution, noise, HU accuracy, and LCD largely equivalent to scans acquired using an actual NR acquisition. At SSDE levels below ~5mGy for the lung protocol, differences in noise magnitude and LCD for NRSHR were >15% which defines a region where NRsim degrades due to contributions from electronic noise.

Similar Papers
  • PDF
  • Research Article
  • Citations93

Physical evaluation of an ultra-high-resolution CT scanner

  • Jan 01, 2020
  • European Radiology
  • Luuk J Oostveen +5
  • Research Article
  • Citations4

Performance of high-resolution CT for detection and discrimination tasks related to stenotic lesions - A phantom study using model observers.

  • Jan 12, 2023
  • Medical physics
  • Andrew M Hernandez +4
  • Research Article
  • Citations10

Improving Low-contrast Detectability and Noise Texture Pattern for Computed Tomography Using Iterative Reconstruction Accelerated with Machine Learning Method: A Phantom Study

  • Jan 07, 2020
  • Academic Radiology
  • Yoshinori Funama +6
  • PDF
  • Supplementary Content
  • Citations37

Quality evaluation of image‐based iterative reconstruction for CT: Comparison with hybrid iterative reconstruction

  • May 02, 2019
  • Journal of Applied Clinical Medical Physics
  • Hiroki Kawashima +5
  • Abstract

OA158] Noise equivalent number of quanta (NEQ): A tool for choosing the optimal reconstruction algorithm in computed tomography (CT)

  • Aug 01, 2018
  • Physica Medica
  • Vittorio Di Trapani +1
  • Conference Article
  • Citations9

Characterization of a prototype tabletop x-ray CT breast imaging system

  • Mar 08, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • J Michael O'Connor +4
  • Research Article

Modulation transfer function (MTF) and noise power spectrum (NPS) studies on three industrial digital radiography (IDR) systems

  • Jun 01, 2009
  • Insight - Non-Destructive Testing and Condition Monitoring
  • K A Mohd Salleh +2
  • Research Article
  • Citations10

Performance evaluation of local ROI algorithms for exact ROI reconstruction in spiral cone-beam computed tomography

  • Jun 01, 2001
  • IEEE Transactions on Nuclear Science
  • K Sourbelle +4
  • Research Article
  • Citations12

Objective performance assessment of five computed tomography iterative reconstruction algorithms.

  • Sep 09, 2016
  • Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
  • Azeez Omotayo +1
  • Conference Article
  • Citations18

Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Wei Zhao +3
  • Research Article
  • Citations22

Signal detection and location‐dependent noise in cone‐beam computed tomography using the spatial definition of the Hotelling SNR

  • May 17, 2012
  • Medical Physics
  • Claudia C Brunner +3
  • Research Article

TH‐EF‐BRA‐05: Investigation of Full Dose Reduction Potential of ASiRâ„¢ for Head CT Protocols in a Predominantly Pediatric Population

  • Jun 01, 2015
  • Medical Physics
  • A Mirro +2
  • Research Article
  • Citations69

A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential.

  • Apr 27, 2018
  • American Journal of Roentgenology
  • André Euler +4
  • Research Article
  • Citations52

Preserving image texture while reducing radiation dose with a deep learning image reconstruction algorithm in chest CT: A phantom study.

  • Jan 01, 2021
  • Physica Medica
  • Caro Franck +3
  • Research Article
  • Citations33

Optimization of contrast-enhanced breast imaging: Analysis using a cascaded linear system model.

  • Jan 01, 2017
  • Medical Physics
  • Yue‐Houng Hu +2
Cactus Communications logo