• Home
  • Search
  • Characterization of a prototype tabletop x-ray CT breast imaging system
  • Cite Icon9
  • https://doi.org/10.1117/12.713751Copy DOI Icon

Characterization of a prototype tabletop x-ray CT breast imaging system

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Planar X-ray mammography is the standard medical imaging modality for the early detection of breast cancer. Based on advancements in digital flat-panel detector technology, dedicated x-ray computed tomography (CT) mammography is a modality under investigation that offers the potential for improved breast tumor imaging. We have implemented a prototype half cone-beam CT breast imaging system that utilizes an indirect flat-panel detector. This prototype can be used to explore and evaluate the effect of varying acquisition and reconstruction parameters on image quality. This report describes our system and characterizes the performance of the system through the analysis of Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS). All CT reconstructions were made using Feldkamp's filtered backprojection algorithm. The 3D MTF was determined by the analysis of the plane spread function (PlSF) derived from the surface spread function (SSF) of reconstructed 6.3mm spheres. 3D NPS characterization was performed through the analysis of a 3D volume extracted from zero-mean CT noise of air reconstructions. The effect of varying locations on MTF and the effect of different Butterworth filter cutoff frequencies on NPS are reported. Finally, we present CT images of mastectomy excised breast tissue. Breast specimen images were acquired on our CTMS using an x-ray technique similar to the one used during performance characterization. Specimen images demonstrate the inherent CT capability to reduce the masking effect of anatomical noise. Both the quantitative system characterization and the breast specimen images continue to reinforce the hope that dedicated flat-panel detector, x-ray cone-beam CT will eventually provide enhanced breast cancer detection capability.

Similar Papers
  • Abstract

OA158] Noise equivalent number of quanta (NEQ): A tool for choosing the optimal reconstruction algorithm in computed tomography (CT)

  • Aug 01, 2018
  • Physica Medica
  • Vittorio Di Trapani +1
  • Research Article
  • Citations6

3D MTF estimation using sphere phantoms for cone-beam computed tomography systems.

  • Apr 18, 2020
  • Medical Physics
  • Changwoo Lee +2
  • Research Article
  • Citations22

Signal detection and location‐dependent noise in cone‐beam computed tomography using the spatial definition of the Hotelling SNR

  • May 17, 2012
  • Medical Physics
  • Claudia C Brunner +3
  • PDF
  • Research Article
  • Citations19

One-year analysis of Elekta CBCT image quality using NPS and MTF.

  • May 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Satomi Nakahara +2
  • Research Article

Modulation transfer function (MTF) and noise power spectrum (NPS) studies on three industrial digital radiography (IDR) systems

  • Jun 01, 2009
  • Insight - Non-Destructive Testing and Condition Monitoring
  • K A Mohd Salleh +2
  • Conference Article
  • Citations18

Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Wei Zhao +3
  • Conference Article
  • Citations49

DQE of direct and indirect digital radiography systems

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Ehsan Samei +3
  • Research Article
  • Citations25

Validation of synthesized normal-resolution image data generated from high-resolution acquisitions on a commercial CT scanner.

  • Aug 05, 2020
  • Medical Physics
  • Andrew M Hernandez +8
  • Conference Article
  • Citations2

Complete MTF evaluation of two cone beam CT systems

  • Mar 08, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Ricardo Betancourt Benítez +2
  • Research Article

Image quality comparison of synthesized two-dimensional images and digital mammography in breast tomosynthesis: A quantitative analysis.

  • Apr 01, 2026
  • Journal of applied clinical medical physics
  • Kazumi Sogabe +3
  • Research Article

SU‐E‐I‐62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

  • May 29, 2014
  • Medical Physics
  • J Collier +2
  • Research Article
  • Citations1

Cone-beam CT with a noncircular (sine-on-sphere) orbit: imaging performance of a clinical system for image-guided interventions.

  • Aug 22, 2024
  • Journal of medical imaging (Bellingham, Wash.)
  • A Kyle Jones +4
  • Research Article
  • Citations2

Performance of Dual-Layer Flat-Panel Detectors.

  • Jul 28, 2025
  • Diagnostics (Basel, Switzerland)
  • Dong Sik Kim +1
  • Research Article
  • Citations33

Optimization of contrast-enhanced breast imaging: Analysis using a cascaded linear system model.

  • Jan 01, 2017
  • Medical Physics
  • Yue‐Houng Hu +2
  • Research Article
  • Citations32

A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

  • Jan 06, 2020
  • Medical Physics
  • N M Sheth +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.